9.3 Other technical data
TOTAL POWER:
Electric supply:
Appliance category:
Gas connection:
Appliance class:
9.4 Gas burners for NATURAL GAS G20 20 mbar
BURNER
Ultra Rapid
Semi-rapid
Auxiliary
9.5 Gas burners for LPG G30/G31 28-30/37 mbar
BURNER
NORMAL
POWER kW
Ultra Rapid
3,3
Semi-rapid
1,85
Auxiliary
1,0
10. ENERGY EFFICIENCY
10.1 Product information according to EU 66/2014
Model identification
Type of hob
Number of gas burners
24
ENGLISH
Gas original:
G20 (2H) 20 mbar
Gas replacement:
G30 (3+) 28-30 mbar
G31 (3+) 37 mbar
220-240 V ~ 50-60 Hz
II2H3+
G 1/2"
3
NORMAL POWER
kW
3,8
1,85
1,0
MINIMUM
POWER kW
1,75
0,55
0,45
MINIMUM POWER kW INJECTOR MARK
1,4
0,45
0,33
INJECTOR
NOMINAL GAS FLOW g/h
MARK
G30 28-30
mbar
90x
240
67
134
52
73
8,5 kW
582 g/h
571 g/h
151
103x
79x
G31 37 mbar
236
132
71
HKB64453NB,