Leitor Honeywell Eclipse MS 5145
Para realizar a leitura do código de barras com o Honeywell MS 5145 é
necessário apenas um simples toque no botão Codegate, tecnologia
patenteada pela Honeywell (Metrologic), que permite ao usuário mirar
com precisão e facilidade no alvo desejado posicionando o feixe de laser
sobre as linhas.
bztech.com.br

Advertisement

Table of Contents
loading

Summary of Contents for Honeywell Eclipse MS5145-38

  • Page 1 Leitor Honeywell Eclipse MS 5145 Para realizar a leitura do código de barras com o Honeywell MS 5145 é necessário apenas um simples toque no botão Codegate, tecnologia patenteada pela Honeywell (Metrologic), que permite ao usuário mirar com precisão e facilidade no alvo desejado posicionando o feixe de laser sobre as linhas.
  • Page 2 MS5100 Eclipse Series User’s Guide...
  • Page 3 Disclaimer Honeywell International Inc. (“HII”) reserves the right to make changes in specifications and other information contained in this document without prior notice, and the reader should in all cases consult HII to determine whether any such changes have been made. The information in this publication does not represent a commitment on the part of HII.
  • Page 4: Table Of Contents

    Table of Contents Introduction ..................... 1 Product Overview ..................... 1 Basic Kit Components ..................2 Optional Accessories ..................2 MS5145 Components ..................4 Maintenance ..................... 4 Caution and Serial Number Labels ..............5 Cable Installation and Removal ................ 6 Installation RS232, Light Pen or Laser Emulation ..............
  • Page 5 Scanner and Cable Terminations Scanner Pinout Connections ................31 Cable Connector Configurations ..............33 Limited Warranty ................... 35 Regulatory Compliance Safety ......................37 EMC ....................... 38 Index ....................... 41 Customer Support ................. 43 Technical Assistance ..................43 Product Service and Repair ................43...
  • Page 6: Introduction

    Product Overview The MS5145 Eclipse is a single-line, hand-held laser scanner. Equipped with Honeywell’s patented CodeGate™ technology, Eclipse can be used in a wide variety of applications. CodeGate technology allows the user to easily target the desired bar code and complete the data transmission with a simple press of a button.
  • Page 7: Basic Kit Components

    Basic Kit Components Part # Description MS5145 Eclipse Scanner 00-02544 MetroSelect Single-Line Configuration Guide* 70-79016 MS5100 Eclipse Series User’s Guide* Manuals are available for download from www.honeywellaidc.com. Optional Accessories Part # Description AC to DC Power Transformer- Regulated 5.2VDC @ 1A output. 46-00525 90VAC to 255VAC, United States, Canada and Japan 46-00526...
  • Page 8 Part # Description RS232 PowerLink Cable with Built-in Power Jack 55-55000x-3 straight cord, long strain relief, black Keyboard Wedge PowerLink Cable with Adapter 55-55002x-3 straight cord, long strain relief, black Stand Alone Keyboard PowerLink Cable, 55-55020x-3 straight cord, long strain relief, black USB Low Speed Communication Cable, Type A 55-55235x-N-3 straight cord, long strain relief, black...
  • Page 9: Ms5145 Components

    MS5145 Components Item No. Description Mode Select Button/CodeGate Button (see page 13) Red LED (see page 15) Green LED (see page 15) Pin Hole for Cable Release (see page 6) Red Output Window (Laser Aperture) Speaker (see page 14) 10-Pin RJ45, Female Socket (see page 31) Figure 1.
  • Page 10: Caution And Serial Number Labels

    Caution and Serial Number Labels Figure 2. Label Location on the Bottom of the Scanner with Example Caution: To maintain compliance with applicable standards, all circuits connected to the imager must meet the requirements for SELV (Safety Extra Low Voltage) according to EN/IEC 60950-1.
  • Page 11: Cable Installation And Removal

    Cable Installation and Removal Installation Insert the cable’s modular connector into the socket on the scanner. Pull gently on the cable strain relief to ensure the cable is installed. Note: If the PowerLink cable is not fully latched, the unit can power intermittently.
  • Page 12: Installation

    Installation RS232, Light Pen or Laser Emulation Turn off the host system. Plug the male, 10-pin RJ45 end of the PowerLink cable into the 10-pin socket on the MS5145. Connect the 9-pin female end of the PowerLink cable to the appropriate communication port on the host device.
  • Page 13: Rs485

    RS485 Turn off the host system. Plug the male 10-pin RJ45 end of the MVC cable into the 10-pin socket on the MS5145. Connect the other end of the MVC cable to Port 9 of the host device. Turn on the host device Figure 6.
  • Page 14: Keyboard Wedge

    Keyboard Wedge Turn off the host system. Plug the male, 10-pin RJ45 end of the PowerLink cable into the 10-pin socket on the MS5145. Disconnect the keyboard from the host/PC. Connect the Y ends of the PowerLink cable to the keyboard and the host’s keyboard port.
  • Page 15: Stand-Alone Keyboard

    Stand-Alone Keyboard Turn off the host system. Connect the 10-pin RJ45 male connector into the jack on the Eclipse. There will be a ‘click’ when the connection is made. Connect the L-shaped plug of the power supply into the power jack on the PowerLink cable.
  • Page 16: Low Speed Usb (-38)

    USB: Low Speed USB (-38) Full Speed USB (-40) Turn off the host system. Connect the 10-pin RJ45 male connector of the USB cable into the jack on the Eclipse. There will be a ‘click’ when the connection is made. Connect the other end of the USB cable to the host USB port.
  • Page 18: Scanner Operation

    Scanner Operation Modes of Operation ® CodeGate , Out-of-Stand  CodeGate activates when removed from the stand  Bar code data is transmitted when the button is pressed Manual Activation Mode*, Out-of-Stand  Button activates laser  Bar code data is scanned and transmitted while button is held down CodeGate Manual Activation Mode* This feature is not a default...
  • Page 19: Audible Indicators

    Audible Indicators When the MS5145 scanner is operational, the scanner provides audible feedback to indicate the status of the scanner and the last scan. Eight settings are available for the tone of the beep (normal, six alternate tones and no tone). For instructions on how to change the tone of the beeper, refer to the Single-Line MetroSelect Configuration Guide.
  • Page 20: Visual Indicators

    Visual Indicators The MS5145 is equipped with a red LED and green LED, which indicate the scanner’s state and the status of the current scan when the unit is in operation. Figure 12. LED Color and Location Green and Red LEDs Are Off The LEDs will not be illuminated if the scanner is not receiving power from the host or transformer.
  • Page 21: Failure Modes

    Failure Modes One Razzberry Tone – On Power Up This indicates the scanner has experienced a laser or flipper subsystem failure. Return the unit for repair to an Authorized Service Center. Continuous Razzberry Tone with no LEDs If, upon power up, the scanner emits a continuous razzberry tone, then the scanner has an experienced an electronic failure.
  • Page 22: Depth Of Field

    Depth of Field by Bar Code Element Width Minimum Bar Code Element Width mils 10.4 Figure 13. Depth of Field by Bar Code Element Width...
  • Page 24: Troubleshooting Guide

    Troubleshooting Guide The following guide is for reference purposes only. Contact a customer service representative (see page 43) to preserve the limited warranty terms. Symptoms Possible Causes Solution All Interfaces No power is being Check the transformer, the outlet supplied to the and power strip.
  • Page 25 Symptoms Possible Causes Solution UPC/EAN, Code 39, interleaved 2 The unit powers The unit is trying to of 5, Code 93, Code 128 and up, but does not scan a particular Codabar are enabled by default. scan and/or symbology that is not Verify the type of bar code being beep.
  • Page 26 Symptoms Possible Causes Solution Make sure that the proper PC type The unit scans The unit’s AT, PS2 or XT is selected. Verify but the data is configuration is not the correct country code and data not correct. correct. format is selected. Adjust the inter-character delay symptom.
  • Page 28: Design Specifications

    Design Specifications Operational Light Source: Visible Laser Diode (VLD) @ 650 nm Laser Power: Less than 1.0 mW average Max Power: 10 mW Embedded Laser: Wavelength: 650 nm Depth of Scan Field: 0 mm – 140 mm (0" – 5.5") 0.33 mm (13 mil) Bar Code Scan Speed: 72 ±...
  • Page 29 Electrical Input Voltage: 5VDC ± 0.25V Power: Operating: 675 mW Current: Operating: 135 mA average @ 5VDC DC Transformers: Class II; 5.2VDC @ 1A For regulatory compliance information, see pages 37 – 39. Environmental Operating: 0°C to 40°C (32°F to 104°F) Temperature: Storage: -40°C to 60°C (-40°F to 140°F)
  • Page 30: Applications And Protocols

    Keyboard Wedge, Stand-Alone Keyboard The MS5145 Keyboard Wedge Series (-47) is designed for keyboard emulation only. Many RS232 configurable functions available in other Honeywell scanners are also available as keyboard wedge functions. The following are the most important selectable options specific to keyboard...
  • Page 32: Configuration And Upgrades

    Configuration and Upgrades Configuration Modes The MS5145 Eclipse has three modes of configuration. • Bar Codes The Eclipse can be configured by scanning the bar codes located in the ® MetroSelect Single-Line Configuration Guide. This manual is available for download at www.honeywellaidc.com. •...
  • Page 33 During configuration, the motor and laser turn off. YOU CANNOT SCAN A BAR CODE WHILE IN SERIAL CONFIGURATION MODE. There is a 20 second window between commands. If a 20 second timeout occurs, the scanner will send a [nak] and you must start over. To enter serial configuration mode, send the following command [stx]999999[etx].
  • Page 34 EXAMPLE #3: The following example shows the events that occur when an invalid bar code is sent. This sample will load the factory default settings and then set the baud rate to 19200. SCANNER HOST ASCII SPONSE FEATURE COMMAND REPRESENTATION [stx]999999[etx] 02h 39h 39h 39h 39h 39h 39h 03h [ack] or 06h Enter Configuration Mode [stx]99999:[etx]...
  • Page 35: Upgrading The Firmware

    Upgrading the Firmware The MS5145 is part of Honeywell’s line of scanners with flash upgradeable firmware. The upgrade process requires a new firmware file supplied to the  customer by a customer service representative and Honeywell’s MetroSet2  software . A personal computer running Windows 95 or greater with an available RS232 serial or USB port is required to complete the upgrade.
  • Page 36: Scanner And Cable Terminations

    Scanner and Cable Terminations Scanner Pinout Connections The MS5145 scanner interfaces terminate to a 10-pin modular jack. The serial number label indicates the interface enabled when the scanner is shipped from the factory. Figure 14. MS5145-41 RS232 and Light Pen Emulation Function Ground RS232 Transmit Output...
  • Page 37 Scanner Pinout Connections Figure 15. MS5145-00 Laser Emulation Function Ground RS232 Transmit Output RS232 Receive Input Flip Sense/Start of Scan Output Proximity Detect/ Trigger Emulation Output Scan/Laser Enable Input Reserved Data Out +5VDC Shield Ground MS5145 Full Speed (-40) and Low Speed (-38) USB Function Ground...
  • Page 38: Cable Connector Configurations

    Cable Connector Configurations RS232 PowerLink Cable, 55-55000 Function Shield Ground RS232 Transmit Output RS232 Receive Input DTR Input/Light Pen Source Power/Signal Ground Light Pen Data (DSR Out for -14 interfaces) 9-Pin D-Type Connector CTS Input RTS Output +5VDC Stand Alone Keyboard PowerLink Cable, 55-55020x-3 Function PC Data...
  • Page 39 PC Clock No Connect Honeywell will supply and adapter cable with a 5-pin DIN male connector on one end and a 6-pin mini DIN female connector on the other According to the termination required, connect the appropriate end of the adapter cable to the PowerLink cable, leaving the necessary termination exposed for connecting to the keyboard and the keyboard port on the PC.
  • Page 40: Limited Warranty

    Limited Warranty Honeywell International Inc. ("HII") warrants its products and optional accessories to be free from defects in materials and workmanship and to conform to HII’s published specifications applicable to the products purchased at the time of shipment. This warranty does not cover any HII product which is (i) improperly installed or used;...
  • Page 41 All provisions of this Limited Warranty are separate and severable, which means that if any provision is held invalid and unenforceable, such determination shall not affect the validity of enforceability of the other provisions hereof. Use of any peripherals not provided by the manufacturer may result in damage not covered by this warranty.
  • Page 42: Regulatory Compliance

    Regulatory Compliance Safety ITE Equipment IEC 60950-1 Second Edition EN 60950-1 Second Edition Laser Laser Class 1: IEC 60825-1: Second Edition, 2007, EN 60825-1: Second Edition, 2007 IEC 62471: Exempt Risk Group Caution Use of controls or adjustments or performance of procedures other than those specified herein may result in hazardous laser light exposure.
  • Page 43: Emc

    Achtung Die Verwendung anderer als der hier beschriebenen Steuerungen, Einstellungen oder Verfahren kann eine gefährliche Laserstrahlung hervorrufen. Der Kunde sollte unter keinen Umständen versuchen, den Laser-Scanner selbst zu warten. Sehen Sie niemals in den Laserstrahl, selbst wenn Sie glauben, daß der Scanner nicht aktiv ist.
  • Page 44 This equipment has been tested and found to comply with limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications.
  • Page 45 Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. Class B Devices The following is applicable when the scanner cable is less than 3 meters (9.8 feet) in length when fully extended: Les instructions ci-dessous s’appliquent aux cables de scanner ne dépassant pas 3 métres (9.8 pieds) de long en extension maximale: Folgendes trifft zu, wenn das Scannerkabel kürzer als 3 Meter ist:...
  • Page 46: Index

    Index interface ........23 Keyboard Wedge .. 1, 3, 9, 25, 31, AC ........see power Laser Emulation ....7, 32 accessories ....... 2, 3 Light Pen ....1, 7, 25, 31 aperture ......... 4 RS232 ..... 1, 2, 7, 25, 31, 33 RS485 .......
  • Page 47 terminations ......31–34 VLD ..........23 tone ......... 1, 14 transformer ..... see power troubleshooting ...... 19–20 warranty ........36 TTL RS232 ....see interface window .......... 4 USB ......see interface...
  • Page 48: Customer Support

    For our latest contact information, please check our website at the link above. Product Service and Repair Honeywell International Inc. provides service for all of its products through service centers throughout the world. To obtain warranty or non-warranty service, please visit www.honeywellaidc.com...
  • Page 49 Honeywell Scanning & Mobility 9680 Old Bailes Road Fort Mill, SC 29707 www.honeywellaidc.com 70-79016 Rev G 12/12...

Table of Contents