Honeywell MetroSelect Eclipse MS 5145 Configuration Manual

Honeywell MetroSelect Eclipse MS 5145 Configuration Manual

Single-line scanner
Hide thumbs Also See for MetroSelect Eclipse MS 5145:
Table of Contents

Advertisement

Leitor
Eclipse MS 5145 (MK 5145)
O melhor custo benefício do mercado. Descubra todas as
vantagens do leitor de código de barras Honeywell Eclipse
MS 5145 (MK 5145). Um dos mais vendidos do mercado.
Conheça.
www.bztech.com.br

Advertisement

Table of Contents
loading

Summary of Contents for Honeywell MetroSelect Eclipse MS 5145

  • Page 1 Leitor Eclipse MS 5145 (MK 5145) O melhor custo benefício do mercado. Descubra todas as vantagens do leitor de código de barras Honeywell Eclipse MS 5145 (MK 5145). Um dos mais vendidos do mercado. Conheça. www.bztech.com.br...
  • Page 2 ® MetroSelect Single-Line Scanner Configuration Guide...
  • Page 3 Disclaimer Honeywell International Inc. (“HII”) reserves the right to make changes in specifications and other information contained in this document without prior notice, and the reader should in all cases consult HII to determine whether any such changes have been made. The information in this publication does not represent a commitment on the part of HII.
  • Page 4: Table Of Contents

    Table of Contents Introduction Bar Code Configuration Methods .............. 1–1 Single-Code Method ................1–1 Multi-Code Method ................1–1 Need to Start Over? .................. 1–2 Code Types and Decode Rules UPC/EAN ....................2–1 Code 128 ....................2–2 Code 39 ....................2–2 2 of 5 Codes .....................
  • Page 5 Scanner Operation Configuration Mode Options ..............7–1 Scan Buffers ....................7–1 Redundant Scans ..................7–2 Miscellaneous Decode Features ............... 7–2 Same Symbol Timeouts ................7–3 LED Options ....................7–3 Beeper Options ..................7–4 Data Transmission Delays ................. 7–6 Communication Timeout Options .............. 7–7 Host Scanner Commands .................
  • Page 6 RS232 Parity Features ..................10–1 Baud Rate ....................10–1 Data/Stop Bits ..................10–2 Hardware Handshaking ................10–2 Software Handshaking ................10–4 Miscellaneous ..................10–5 Keyboard Enable Keyboard Emulation ..............11–1 Country/Scan Code Table Selects ............11–1 Keyboard/System Type................11–2 ’Dumb’ Terminal Selections ..............11–3 Special Keyboard Features ..............
  • Page 7 ® ® MS9520 Voyager and MS9540 VoyagerCG Series Activation Range ..................17–1 Stand Scan Modes .................. 17–1 CodeGate® Status .................. 17–1 Laser/Scan Modes .................. 17–2 Same Symbol Time Outs................. 17–3 MS9520/9540-00 Laser Emulation Mode ..........17–4 ® MS9524 and MS9544 VoyagerPDF Series PDF CodeGate Status ................
  • Page 8: Bar Code Configuration Methods

    Your new scanner has been factory configured with a set of default parameters. Since many host systems have unique formats and protocol requirements, Honeywell provides a wide range of configurable features that may be selected using this bar code based configuration tool. Once the configuration is completed, the scanner stores the settings in nonvolatile memory (NOVRAM).
  • Page 9: Need To Start Over

    All other scanners load RS232 defaults. Note: Honeywell manufactures several products for OEM applications. These OEM products are configured with custom OEM defaults, which may use a different set of defaults than the standard set of factory defaults.
  • Page 10: Code Types And Decode Rules

    Code Types and Decode Rules Bar code descriptions marked with an asterisk ( * ) define a feature that is a factory default. Bar codes marked with a tilde ( ~ ) require the Multi-Code configuration method. UPC/EAN * Enable UPC/EAN ³...
  • Page 11: Code 128

    Code 128 * Enable Code 128 ³ Disable Code 128 ³ Enable UCC/EAN-128 ‘]C1’ Code Formatting – For Coupon Code 128, see page 3–3. ³ * Disable UCC/EAN-128 ‘]C1’ Code Formatting ³ Ignore <FNC4> Code 128 Characters ³ * Use <FNC4> to Determine Extended ASCII Characters ³...
  • Page 12 Enable PARAF (Italian Pharmaceutical Codes) Support – Code 39 bar codes are converted to ³ PARAF format. * Disable PARAF Support ³ * Allow PARAF Codes Only ³ Allow Non-PARAF Codes ³ Enable TRI-OPTIC Code ³ * Disable TRI-OPTIC Code ³...
  • Page 13: Of 5 Codes

    Enable Alternate Code 39 Reference Comparison Check – assists with elements that ³ are below the 2 to 1 (wide to narrow) element width requirement. * Normal Code 39 Reference Comparison Check ³ ODES * Enable Interleaved 2 of 5 (ITF) ³...
  • Page 14 Alternative ITF first Bar Reference ³ * Normal ITF first Bar Reference ³ Enable Standard 2 of 5 ³ * Disable Standard 2 of 5 ³ ~ Standard 2 of 5 Symbol Length – To specify the number of characters to be decoded, scan ³...
  • Page 15: Codabar

    Enable Hong Kong 2 of 5 ³ * Disable Hong Kong 2 of 5 ³ Enable Follett ITF ³ * Disable Follett ITF ³ Codabar * Enable Codabar ³ Disable Codabar ³ Enable Dual Field Codabar ³ * Disable Dual Field Codabar ³...
  • Page 16: Telepen

    * Disable Code 11 ³ * Check for 1 Code 11 Check Digit ³ Check for 2 Code 11 Check Digits ³ * Do Not Check for 2 Code 11 Check Digits ³ Check for 2 Code 11 Check Digits if Code Length is Greater Than 10 Characters ³...
  • Page 17: Additional Decode Features

    Enable MSI Plessey MOD 10/10 Check Digit – Test MSI Plessey bar codes for a 2 digit ³ Modulo 10 check digit. * Enable MSI Plessey MOD 10 Check Digit – Test MSI Plessey bar codes for a 1 digit ³...
  • Page 18: Configurable Code Lengths

    ~ Minimum Symbol Length – Single-line default is 3. Combine this code with the proper code bytes ³ (on page 16–1), to specify the minimum number of characters in all non-UPC/EAN bar codes. ~ Symbol Length Lock – Combine this code with the proper code bytes, to lock the bar code’s ³...
  • Page 19 ~ Code Length Lock #2 ³ ~ Code Type Lock #2 ³ ~ Code Length Lock #3 ³ ~ Code Type Lock #3 ³ ~ Code Length Lock #4 ³ ~ Code Type Lock #4 ³ ~ Code Length Lock #5 ³...
  • Page 20: Supplements

    Supplements Enable Two Digit Supplements ³ * Disable Two Digit Supplements ³ * Enable Two Digit Redundancies – The scanner will scan the bar code plus the 2 digit add on ³ twice before accepting data. Disable Two Digit Redundancies ³...
  • Page 21 Enable Bookland (978) Supplement Required ³ * Disable Bookland (978) Supplement Required ³ Enable 977 (2 Digit) Supplement Required – The scanner will require a 2 digit supplement to be ³ scanned when an EAN-13 code begins with 977. * Disable 977 (2 Digit) Supplement Required ³...
  • Page 22 * Enable 2 Digit Supplements with 37x, 43x, or UPC # System 5 ³ Disable 2 Digit Supplements with 37x, 43x, or UPC # System 5 ³ * Enable 5 Digit Supplements with 37x, 43x, or UPC # System 5 ³...
  • Page 23 Enable Code ID’s with Supplements ³ * Disable Code ID’s with Supplements ³ * Beep Once on Supplements ³ Beep Twice on Supplements ³ Enable ISBN Check Digit Transmission – Not available with all models. ³ Disable ISBN Check Digit Transmission ³...
  • Page 24 Disable Supplemental when CodeGate Button is Pressed – Available for MS9540 scanners ³ only. Requires standard Code Gate be inactive in and out of stand. * CodeGate Does Not Affect Supplemental Scanning – Available for MS9540 scanners only. ³ No Supplement Checking if EAN-13 Code is just scanned ³...
  • Page 25 3–6...
  • Page 26: Gs1 Databar

    #14810 and higher can be configured to scan GS1 DataBar type bar codes. Double Border Required – Due to the large spaces commonly found in GS1 DataBar ³ symbologies, Honeywell recommends double border requirements be enabled when scanning GS1 DataBar code type symbologies. Enable GS1 DataBar 14 ³...
  • Page 27: Gs1 Databar Limited

    GS1 DataBar Limited Enable GS1 DataBar Limited ³ * Disable GS1 DataBar Limited ³ * Transmit GS1 DataBar Limited CD ³ Do Not Transmit GS1 DataBar Limited CD ³ * Transmit GS1 DataBar Limited Application ID – Application identifier “01” is transmitted by default. ³...
  • Page 28: Isbt Code 128 Implementation

    ISBT Code 128 Implementation Configuration Mode Enable ISBT Code 128 ³ Disable ISBT Code 128 ³ The bar codes below enable or disable a special transmit mode as outlined in section 3.5.2 of the ISBT-128 Specification. This output method allows the user to confirm independently the accuracy of the Code-128 check digit.
  • Page 29: Concatenation Configuration Mode

    † Concatenation Configuration Mode The following bar codes are used to configure variable time requirements used to find the second bar code of the ISBT concatenation sequence. 100 msec to Find Concatenation Sequence ³ 200 msec to Find Concatenation Sequence ³...
  • Page 30: User-Defined Concatenation Configuration Mode

    Donation Identification Number + Donor Identification Number =á + &; Concatenation ³ Donation Identification Number + Confidential Unit Exclusion Status =á + &! Concatenation ³ Product Code + Expiration Date (Form 1) =< + =>Concatenation ³ Product Code + Expiration Date (Form 2) =<...
  • Page 31 The following example demonstrates how to configure the User-Defined ISBT identifiers: Assume the left-hand identifiers are the ISBT defined donation identification number: “=G”; and the right hand identifiers are country specific identifiers “&a”. Scan the ENTER/EXIT configuration mode bar code. Scan the 1 Left Identifier configuration mode bar code.
  • Page 32: Communications

    Communications Enable Light Pen/Wand Communication – Use this option if scanner should be used in ³ place of a light pen. * Enable RS232 – The scanner will work with RS232 +/- 12V serial output. ³ Load Keyboard Wedge Defaults – Scan this code before selecting Normal or Stand Alone ³...
  • Page 33 6–2...
  • Page 34: Scanner Operation

    Scanner Operation Configuration Mode Options Allow Configuration Mode on Power Up – The scanner can only enter MetroSet mode before ³ any bar codes are scanned. * Allow Configuration Mode Anytime – Allow MetroSet configuration at any time. ³ Allow configuration Codes on Power Up – Once a product bar code is scanned after power- ³...
  • Page 35: Redundant Scans

    Redundant Scans * 0 Redundant Scans – Requires 1 good decode for a good scan. ³ 1 Redundant Scan – Requires 2 consecutive decodes of the same bar code data for a good ³ scan. 2 Redundant Scans – Requires 3 consecutive decodes of the same bar code data for a good ³...
  • Page 36: Same Symbol Timeouts

    Same Symbol Time Outs The length of time before a bar code can be rescanned after it is removed from the scan field is user-configurable in increments of 50 msecs to 6350 msecs (6.35 sec). If using an MS9500 or IS4125, go to page 17–3. ~ Variable Same Symbol Time Out –...
  • Page 37: Beeper Options

    Beeper Options * Normal Tone ³ Optional Tone 1 ³ Optional Tone 2 ³ Optional Tone 3 ³ Optional Tone 4 ³ Optional Tone 5 ³ Optional Tone 6 ³ No Beep ³ * Beep Once on Supplements ³ Beep Twice on Supplements ³...
  • Page 38 Beep on BEL Command – The scanner beeps when it receives a BEL character from the host. If ³ a number is sent within 200 msecs before the BEL character, the scanner will beep that number of times. * Ignore BEL Command ³...
  • Page 39: Data Transmission Delays

    Data Transmission Delays Use these codes to select the amount of delay between sending data characters from the scanner to the host. This helps prevent the scanner from overflowing host-input buffers. * 1 msec Intercharacter Delay ³ 10 msec Intercharacter Delay ³...
  • Page 40: Communication Timeout Options

    Communication Time Out Options Enable Communications Time Out ³ * Disable Communications Time Out ³ * Beep Before Transmit ³ Beep After Transmit ³ ~ Variable Communications Time Out ³ * Default Communications Time Out (2 secs) ³ Short Communications Time Out (1 secs) ³...
  • Page 41: Host Scanner Commands

    Host Scanner Commands Enable D/E Disable Command – The scanner will disable scanning after it receives an ASCII ³ “D” from the host device. It will enable scanning when it receives an ASCII “E”. * Disable D/E Disable. ³ Enable Z/R Type D/E Simulation – The scanner will disable scanning after it receives an ASCII ³...
  • Page 42 Transmit Scanner ID byte with receipt of an “i” (69H) via RS232 – The ID byte is transmitted ³ as 3 bytes (i.e. 0, 0, 1). * Don’t Transmit Scanner ID byte with receipt of an “i” (69H) via RS232 ³...
  • Page 43: Test Modes

    Scan Count Mode ON – The scanner will enter scan count test mode and the scanner’s firmware ³ number will transmit to the host. Do not enable unless instructed by a Honeywell representative. * Scan Count Mode OFF ³ Power-Up with Saved Interface – Do not enable unless instructed by a Honeywell ³...
  • Page 44: Prefixes/Suffixes

    Prefixes/Suffixes Scan the Enter Configuration Mode bar code before trying to set these features (see the Multi-Code Method on page 1–1). User Configurable Prefixes, All Data ~ Configurable Prefix Character #1 – A prefix ID can be added and assigned for data transmission. ³...
  • Page 45: User Configurable Id Characters, Code Specific

    User Configurable ID Characters, Code Specific * Use Configurable Code ID Bytes as Prefixes – User configured, code specific ID bytes are ³ transmitted before the data. If using prefixes, user configured suffixes cannot be used. Use Configurable Code ID Bytes as Suffixes – User configured, code specific ID bytes are ³...
  • Page 46 ‡ Enter configuration mode then scan this bar code followed by the three code byte bar codes (on page 16–1) that represent a unique ID character to be associated with this bar code type. ~ Configurable TRI-OPTIC ID ‡ ³ ~ Configurable Standard 2 of 5 ID ‡...
  • Page 47: Standard Prefix Characters

    Standard Prefix Characters Enable STX Prefix – The scanner will transmit a Start of TeXt (ASCII 02H) before each bar code. ³ * Disable STX Prefix ³ Enable Rochford-Thomson Mode ³ * Disable Rochford-Thomson Mode ³ Enable AIM ID Characters ³...
  • Page 48 Enable SANYO ID Characters ³ * Disable SANYO ID Characters ³ Enable Manufacturer ID Prefix ³ * Disable Manufacturer ID Prefix ³ Enable “C” Prefix ³ * Disable “C” Prefix ³ Enable “$” Prefix ID for UPC/EAN ³ * Disable “$” Prefix ID for UPC/EAN ³...
  • Page 49: Standard Suffix Characters

    Enable Tec 7-11 IDs ³ * Disable Tec 7-11 IDs ³ Standard Suffix Characters Enable CR Suffix – The scanner transmits a carriage return after each bar code. ³ Disable CR Suffix. ³ Enable LF Suffix – The scanner transmits a line feed after each bar code.
  • Page 50: Longitudinal Redundancy Check

    Enable NCR Suffix Character ³ Longitudinal Redundancy Check A Longitudinal Redundancy Check (LRC) is an error checking character that is calculated across a sequence of data characters. It is determined by eXclusive ORing (XOR) the characters to be checked, starting with an initial value of 00H.
  • Page 51: Character Replacements

    Character Replacements To replace a character: Scan the enter/exit configuration mode bar code (on page 1–1). Scan the character to replace code (shown below). Scan the ASCII code byte value of the character you wish to replace. Refer to the ASCII Reference Table in the Code Byte Usage section of this manual.
  • Page 52: User Configurable Suffixes, All Data

    User Configurable Suffixes, All Data Note: Scan the Enter/Exit Configuration mode code before trying to set this feature. Refer to Multi-Code Method on page 1–1. ~ Configurable Suffix Character #1 – A suffix ID can be added and assigned for data ³...
  • Page 53: Special Formats

    Special Formats Enable SINEKO Mode ³ * Disable SINEKO Mode ³ Enable Newcode Formatting Mode A ³ * Disable Newcode Formatting Mode A ³ Enable Newcode Formatting Mode B ³ * Disable Newcode Formatting Mode B ³ Remove All Leading Zero’s ³...
  • Page 54: Code Formatting

    Code Formatting UPC/EAN Formatting * Transmit UPC-A Check Digit ³ Do Not Transmit UPC-A Check Digit ³ Transmit UPC-E Check Digit ³ * Do Not Transmit UPC-E Check Digit ³ Expand UPC-E to 12 Digits – Expand UPC-E bar codes to the 12 digit equivalent, UPC-A bar codes. ³...
  • Page 55 Transmit Lead Zero on UPC-E – This option will transmit a zero before each UPC-E bar code. ³ Do Not Transmit Lead Zero on UPC-E ³ Convert EAN-8 to EAN-13 – The scanner will transmit five zeros before the bar code to convert ³...
  • Page 56: Codabar Formatting

    Codabar Formatting Transmit Codabar Start/Stop Characters – Transmits Codabar’s Start/stop characters before ³ and after each bar code. * Do Not Transmit Codabar Start/Stop ³ * Normal Codabar Start/Stop Characters ³ Enable Transmit Codabar Start/Stop Characters as Lower Case Characters ³...
  • Page 57: Code 39 Formatting

    Code 39 Formatting Transmit Mod 43 Check Digit on Code 39 – This feature works in conjunction with Mod 43 ³ Check Digit on Code 39 option, on page 2–2. Both must be enabled for this feature to work. * Do Not Transmit Mod 43 Check Digit on Code 39 ³...
  • Page 58: Plessey

    Plessey Transmit UK Plessey Check Digit – The scanner will transmit UK Plessey Check Digit characters ³ and must be used with the UK Plessey option. * Do Not Transmit UK Plessey Check Digit ³ Enable UK Plessey Special Format ³...
  • Page 59 9–6...
  • Page 60: Rs232

    RS232 * Enable RS232 Mode – The scanner will work with RS232 +/-12V serial output. ³ Parity Features A parity bit is an extra data bit used to help catch data transmission errors. The scanner’s parity must match the host’s parity. No Parity ³...
  • Page 61: Data/Stop Bits

    * 9600 BAUD Rate ³ 4800 BAUD Rate ³ 2400 BAUD Rate ³ 1200 BAUD Rate ³ 600 BAUD Rate ³ 300 BAUD Rate ³ Data/Stop Bits 8 Data Bits – The number of data bits transmitted for each character. ³...
  • Page 62 * Character RTS/CTS – Activates/Deactivates RTS signal for each character. ³ Message RTS/CTS – Activates RTS before sending the first character and leaves it active ³ until after the last character has been transmitted. Invert RTS Polarity (RSV1) -12V = Active +12V = Inactive ³...
  • Page 63: Software Handshaking

    Enable RTS Counter Toggle – The scanner will toggle the RTS line on a good decode. ³ * Disable RTS Counter Toggle ³ Enable XON/XOFF Handshaking – The scanner will stop transmission whenever on XOFF ³ (ASCII 13H) is received. Transmission will resume after an XON (ASCII 11H) is received.
  • Page 64: Miscellaneous

    Enable 5 NAK Retries Allow up to 5 retransmissions of the data if a ³ NAK is received. * Disable 5 NAK Retries ³ Enable GLS Handshaking – Accept ]V for the ACK acknowledgement. ACK will no longer be ³ accepted but NAK and any additional ACK/NAK protocol characters enabled are still accepted.
  • Page 65 10–6...
  • Page 66: Keyboard

    Keyboard Enable Keyboard Emulation Load Keyboard Wedge Defaults – Loads the default settings for keyboard wedge mode. ³ Enable Stand-Alone Keyboard Emulation – Use this with special stand-alone models that are ³ not cabled for an external keyboard. Scan this bar code to enable the Stand-Alone Mode.
  • Page 67: Keyboard/System Type

    Belgium Keyboard ³ Japan Keyboard ³ IBM 4700 Financial Keyboard ³ Sweden/Finland Keyboard ³ Slovenian Keyboard ³ Keyboard/System Type * AT Keyboard – Includes IBM PS/2 and compatible models 50, 55, 60, 80. ³ XT Keyboard – Special firmware in Voyager. ³...
  • Page 68: Dumb' Terminal Selections

    ‘Dumb’ Terminal Selections Note: The following terminals may require custom cables. IBM Terminal Keyboards ³ Reserved Terminal Keyboard #2 ³ Reserved Terminal Keyboard #3 ³ Reserved Terminal Keyboard #4 ³ Reserved Terminal Keyboard #5 ³ Reserved Terminal Keyboard #6 ³ Reserved Terminal Keyboard #7 ³...
  • Page 69: Special Keyboard Features

    Special Keyboard Features Transmit Make Code Only – Not available on all models. ³ * Transmit Make/Break Code – Not available on all models. ³ * Transmit FOH Break Code – The scanner will transmit the FOH in the break-code sequence. ³...
  • Page 70 Enable Auto Detect Mode (AT/PS2) – Automatically detects caps lock status. ³ * Disable Auto Detect Mode (AT/PS2) ³ Enable Caps Lock (XT) ³ * Disable Caps Lock (XT) ³ Send Numbers as Keypad Data – All data is sent as if it has been entered on a keypad. ³...
  • Page 71: Interscan Code Delays

    Enable Right Alt Key Sequencing ³ Disable Right Alt Key Sequencing ³ Enable LaCaixa Special Keyboard Prefix & Suffix Scan Codes ³ * Disable LaCaixa Special Keyboard Prefix & Suffix Scan Codes ³ InterScan Code Delays * InterScan Code Delay 800 msec – The time specified represents the amount of time between ³...
  • Page 72: Control Sets

    Control Sets In general, standard bar code symbologies will only encode the ASCII character set. Function keys, arrow keys and many other extended keys on an IBM compatible keyboard do not translate to ASCII characters. One method of ‘bar coding’ the extended keys is to substitute the extended key codes when a specific ASCII control character is found in the bar code stream.
  • Page 73 ASCII (HEX) ASCII Control Extended Key Null Numeric Keypad + (Plus) Num Lock Down Arrow Numeric Keypad - (Minus) Insert Delete System Request  (Right Arrow)  (Left Arrow) Caps Lock Shift Tab Left Alt Enter Left Control Up Arrow Home Page Up Page Down...
  • Page 74: Ocia

    OCIA Enable OCIA Mode – Select this option if communications requires OCIA (Optically ³ Coupled Interface Adapter). The host clocks this serial interface. Load OCIA Defaults ³ Enable DTS/Siemens ³ * Enable DTS/Nixdorf ³ Enable NCR-S ³ Enable NCR-F ³ * Transmit character count with non-UPC codes while transmitting in OCIA NCR-S mode ³...
  • Page 75 12–2...
  • Page 76: Light Pen Parameters

    Light Pen Parameters Enable Light Pen Mode – Select this option if the scanner will be used in place of a light pen. ³ It provides light pen emulation of each bar code scanned. * Bars High ³ Spaces High ³...
  • Page 77: Set Narrow Element Width

    Set Narrow Element Width 10x Narrow Element Border – Allows the transmission of Light Pen/Wand emulation using ³ a 10x border. * 50x Narrow Element Border – Allows the transmission of Light Pen/Wand emulation using ³ a 50x border. * 1 ms Narrow Element Width – Allows the transmission of Light Pen/ Wand emulation at ³...
  • Page 78: Ibm Port

    ® 46xx Configuration IBM Port Enable RS485 Communication – For RS485 communications. Not all scanners support this ³ interface. The correct interface board is required. Load RS485 Defaults – Load default format settings for the RS485 systems. ³ IBM Port 17B 3687-2 In Counter ³...
  • Page 79 14–2...
  • Page 80: Usb

    Enable USB Interface ♦ ³ Enable Low Speed USB Defaults ♦ ³ ♦ This feature is limited to Honeywell scanners without integrated Low Speed USB electronics. These bar codes configure the scanner to communicate via the MX009. Load Integrated Full Speed USB Keyboard Emulation Defaults ³...
  • Page 81 Enable Uni-Directional USB Serial Emulation Mode –Supported in Honeywell MS9500, ³ MS5100 and IS4125 laser-class products. Note: This bar code enables Bi-Directional USB Serial Emulation Mode in the Honeywell ® Focus area-imaging products. Enable Bi-Directional USB Serial Emulation Mode – Supported in Honeywell MS9500, ³...
  • Page 82: Code Bytes Usage

    Code Bytes Usage The scanner must be in Configuration Mode for the features requiring code bytes for configuration. The Enter/Exit Configuration Mode bar code must be scanned before starting the configuration cycle. User configurable prefix/suffix characters can then be saved by scanning the 3 digit decimal equivalent of the ASCII character into the appropriate character location with the code byte bar codes.
  • Page 83: Reserved Codes

    Code Byte 8 ³ Code Byte 9 ³ Reserved Codes ~ Enable Reserved Code – Contact Honeywell for information about this feature. ³ ~ Disable Reserved Code ³ Code Type Table Code Byte Code Types UPC-A UPC-E EAN-8 EAN-13 Code 39...
  • Page 84: Ascii Reference Table

    ASCII Reference Table Decimal Value/ Control HEX Value Character Code Byte Value Keyboard Eqv 16–3...
  • Page 85 Decimal Value/ Control HEX Value Character Code Byte Value Keyboard Eqv space,blank “ & ‘ apostrophe comma minus period number zero number one 16–4...
  • Page 86 Decimal Value/ Control Keyboard HEX Value Character Code Byte Value < less than > greater than shift P letter l letter O 16–5...
  • Page 87 Decimal Value/ Control Keyboard HEX Value Character Code Byte Value shift K shift L shift M à,shift N ♣, shift 0, underscore ‘ accent grave 16–6...
  • Page 88: Extended Key Code Reference Table

    Decimal Value/ Control HEX Value Character Code Byte Value Keyboard Eqv vertical slash alt mode (alt mode) delete, rubout Extended Key Code Reference Table At Scan PS2 Scan Prefix/Suffix Value 3151 Code Code Hex = Decimal  80H = 128 ...
  • Page 89 At Scan PS2 Scan Prefix/Suffix Value 3151 Code Code Hex = Decimal 97H = 151 98H = 152 99H = 153 9AH = 154 9BH = 155 Numeric + 9CH = 156 Numeric - 9DH = 157 Numeric * 9EH = 158 Caps Lock 9FH = 159 Num Lock...
  • Page 90: Ms9520 Voyager

    ® MS9520 Voyager ® MS9540 VoyagerCG Series Activation Range Use these bar codes to select infrared (IR) sensor activation range for sensing when objects are placed in the scan field. * Long Range In Stand ³ Short Range In Stand ³...
  • Page 91: Laser/Scan Modes

    * CodeGate Active Out of Stand ³ CodeGate Inactive Out of Stand ³ Laser/Scan Modes * Normal Scan – The laser turns on after the IR senses a bar code. The laser remains on for ³ approximately 3 to 10 seconds. Blinky Scan –...
  • Page 92: Same Symbol Time Outs

    Same Symbol Time Outs If using an MS5145 Eclipse, the MS9524 or MS9544 VoyagerPDF, go to page 7–3. No Same Symbol Time Out ³ 1000 msec Same Symbol Time Out ³ * 875 msec Same Symbol Time Out ³ 750 msec Same Symbol Time Out ³...
  • Page 93 MS9520-00 and MS9540-00 Laser Emulation Mode The MS9520-00 and MS9540-00 leave the factory with Laser Emulation interface enabled. If you recall defaults while re-configuring your scanner, scan the following bar code to re-enable the Laser Emulation interface. The scanner you are using must be labeled as an MS9520-00 or MS9540-00 to support this feature.
  • Page 94: Ms9524 And Ms9544 Voyagerpdf

    MS9524 and MS9544 ® VoyagerPDF Series * Enable PDF ³ Disable PDF ³ * Enable Audible Indicator ³ Disable Audible Indicator ³ PDF CodeGate Status Enable PDF CodeGate in Stand ³ * Disable PDF CodeGate in Stand ³ Enable PDF CodeGate Out of Stand ³...
  • Page 95 Disable GS1 DataBar 2D Linkage ³ Enable UPC/EAN Linkage – Link UPC/EAN symbols with a 2D composite constituent then ³ transmit. * Disable UPC/EAN Linkage ³ * Enable Code 128 Linkage – Transmit the 1D Code 128 without scanning the 2D portion. ³...
  • Page 96: Ms9535 Voyagerbt

    ® MS9535 VoyagerBT ® The MS9535 can act as a client to other devices equipped with Bluetooth wireless technology. If the device’s address is a 12-digit hex value that does NOT start with a FNC3 (e.g., 000CA700118) the user must first scan the Get BT Address bar code (below), and then scan the device’s address bar code.
  • Page 97 * Disable Range Gate ³ Enable BT Test – The cradle will display certain connection information (KO, OK, etc.). ³ Note: Do not enable this feature unless instructed to by a Honeywell representative. * Disable BT Test ³ 19–2...
  • Page 98: Ms9535-5M Voyagerbt

    MS9535-5M VoyagerBT Enable Inventory Mode – Bar code data that is scanned is stored in the scanner’s expanded ³ memory base. The data will be transmitted when the scanner is placed back into its BT cradle. Note: A special beep will sound when a bar code is scanned but not stored due to a full a memory base.
  • Page 99 Clear Inventory Records – Will clear all stored bar code data in memory. ³ Enable Auto Clear Records – Will automatically clear the stored records in the inventory buffer ³ after transmission of the records stored. * Maintain Records ³ Delete Last Record –...
  • Page 100: Inventory Quantity Bar Codes

    Inventory Quantity Bar Codes** The following inventory quantity bar codes will enable the user to enter a quantity from 1 to 9999 for the last item (bar code) scanned. The item’s bar code data will be retransmitted as many times as the quantity indicates. Example: Scan the item’s bar code (ie.
  • Page 101 20–4...
  • Page 102: Is4125 And Is4225 Scan Engines

    IS4125 and IS4225 Scan Engines Disable Old Serial Program ³ Enable Old Serial Program ³ Enable TTL UART ³ Enable Non Buffered TTL UART ³ Enable Detect and Notify Mode ³ Cunningham Defaults – Scan this code followed by Recall Defaults code to enable and ³...
  • Page 103 21–2...
  • Page 104: Is4823 And Is4825 Scan Engines

    IS4823 and IS4825 Scan Engines Operating Modes Activation Modes * Activate Scanning with the External Trigger – An external I/O pin is used to enable the scanning ³ cycle. A High-to-Low transition on the I/O signal is used to activate scanning. The signal must be deactivated (HIGH) and re-activated for subsequent scanning cycles.
  • Page 105 Activation Mode Features ~ Variable Laser-On Time Out – Scan this bar code with a code byte sequence (on page 16–1) ³ that represents the desired time out increment. The configurable time increment (1-second increments) selected is the scanning laser-on time.
  • Page 106 Detect and Notify Mode (Monitor the External Trigger) – The external I/O pin used in the default ³ activation mode is monitored during the inactive laser cycles. An <SI> is transmitted when the I/O is active and an <SO> when it is inactive. Once the scanning activation cycle is started, the external I/O monitoring status is maintained until the scanning cycle is terminated regardless of the...
  • Page 107 22–4...
  • Page 108: Miscellaneous Features

    Custom Defaults Honeywell manufactures several scanners for OEM applications. These scanners may use a different set of defaults than Honeywell factory defaults. Scanning the bar code will reset the default table to Honeywell defaults. Enable Factory Defaults – Scan this code followed by Recall Defaults code to enable and ³...
  • Page 109: Serial Program Mode

    Serial Program Mode For Serial Program Mode, all commands must be framed by an STX (02 Hex) and ETX (03 Hex). To recall defaults: Transmit <STX>999999<ETX> through the Serial Port. This will put the scanner in serial program mode. Scanning will be suspended and the scanner will respond with an ACK (06 Hex).
  • Page 110: Customer Support

    E-mail: hsmlasupport@honeywell.com Brazil Telephone: +55 (11) 5185-8222 Fax: +55 (11) 5185-8225 E-mail: brsuporte@honeywell.com Mexico Telephone: 01-800-HONEYWELL (01-800-466-3993) E-mail: soporte.hsm@honeywell.com Europe, Middle East, and Africa Telephone: +31 (0) 40 7999 393 Fax: +31 (0) 40 2425 672 E-mail: hsmeurosupport@honeywell.com Hong Kong...
  • Page 111: Product Service And Repair

    Product Service and Repair Honeywell International Inc. provides service for all its products through service centers throughout the world. To obtain warranty or non-warranty service, contact the appropriate location below to obtain a Return Material Authorization number (RMA #) before returning the product.
  • Page 112 Online Product Service and Repair Assistance You can also access product service and repair assistance online at www.honeywellaidc.com 24–3...
  • Page 117 Honeywell Scanning & Mobility 9680 Old Bailes Road Fort Mill, SC 29707 www.honeywellaidc.com 00-02544 Rev K 2/11...