Honeywell Unitary Series Installation Instructions Manual
Honeywell Unitary Series Installation Instructions Manual

Honeywell Unitary Series Installation Instructions Manual

Controller-24 vac / vdc
Table of Contents

Advertisement

Unitary
CONTROLLER-24 VAC/VDC
General ............................................................................ 3
Trademark Information ............................................... 3
Product Description...................................................... 3
Controller Part Numbers ............................................ 4
Dimensions ...................................................................... 4
Unitary Controller Large....................................... 4
Unitary Controller Small....................................... 5
Network Security .......................................................... 5
General Safety Instructions....................................... 5
Specifications ................................................................ 6
Electrical ........................................................................... 6
Operational Environment........................................... 6
Hardware........................................................................... 6
Communications ........................................................... 6
T1L Communication..................................................... 7
Supported Devices* ...................................................... 7
Weight and Dimensions.............................................. 7
Universal IO*.................................................................... 7
Wire Gauge Range......................................................... 8
Solid State Relay (SSR)................................................ 8
Relays ................................................................................. 8
Hardware overview....................................................... 9
System Overview............................................................ 9
Service Button................................................................. 10
Mounting ..................................................................... 10
Before Installation......................................................... 10
DIN Rail Mounting ........................................................ 10
Wall Mounting ................................................................ 11
Power Supply.............................................................. 12
General Information ..................................................... 12
Power Wiring.................................................................... 12
Power Wiring Examples............................................... 13
Grounding......................................................................... 13
Input / Output Wiring .............................................. 14
Wiring Requirements ................................................... 14
Internal Wiring Examples ........................................... 15
Terminal Connections.................................................. 17
UIO Wiring Examples ................................................... 19
SSR (DO) Wiring Examples ........................................ 20
Auxiliary Wiring Examples ........................................ 21
DO Relay Wiring Examples ........................................ 21
Network Concepts ..................................................... 22
The RS-485 Standard .................................................. 22
TIA/EIA 485 Cable Specifications .................... 22
IP Network Topologies ................................................. 22
Daisy Chain Topology .................................................. 22
Ring Topology.................................................................. 22
® U.S. Registered Trademark
Copyright © 2024 Honeywell Inc. • All Rights Reserved
INSTALLATION INSTRUCTIONS
BACnet™ IP Controller.............................................. 23
Connecting to an IP network .................................... 23
DHCP IP Configuration............................................... 23
Link-local addressing.................................................. 23
BACnet™ MS/TP Wiring........................................... 24
Auto Baud rate functionality..................................... 24
Termination Resistors ................................................. 24
Shield Termination ....................................................... 24
BACnet™ MS/TP Wiring Example........................... 25
Common Example........................................................ 25
BACnet™ MS/TP Controller .................................... 26
BACnet™ MS/TP Limitations ................................... 26
Physical Limitation ................................................ 26
AutoMAC limitation................................................ 26
Automatic MAC Addressing ...................................... 26
Set the MS/TP MAC Address.................................... 26
Set the Device Instance Number ...................... 27
T1L Communication standard ............................... 28
Daisy Chain Topology.................................................. 28
Ring Topology................................................................. 28
Modbus RTU................................................................ 29
Wiring Topology ............................................................. 29
Cables and Shielding................................................... 29
Modbus RS-485 Repeaters....................................... 29
Modbus Client Specifications.................................. 29
Modbus Compliance.................................................... 29
Modbus Considerations ............................................. 30
Sylk™ ............................................................................. 31
Supported Sylk™ devices............................................ 31
Sylk™ Wiring Example ................................................. 32
Troubleshooting......................................................... 33
LED Interface.................................................................. 34
Controller LED Status ................................................. 34
Bluetooth LED Status.................................................. 35
BACnet™ MS/TP LED Status.................................... 35
Modbus LED Status..................................................... 35
T1L LED Status.............................................................. 36
Service Pin LED Status ............................................... 36
Regulatory Information ........................................... 37
FCC Regulation.............................................................. 37
ISED non-interference disclaimer ......................... 37
Professional Installation Warning ................... 37
Wireless Connectivity .................................................. 37
CE Statement.................................................................. 38
Standards and Compliance ...................................... 38
Approvals and Certifications .................................... 38
31-00614-01

Advertisement

Table of Contents
loading

Summary of Contents for Honeywell Unitary Series

  • Page 1: Table Of Contents

    CE Statement..............38 IP Network Topologies ..........22 Standards and Compliance ........38 Daisy Chain Topology ..........22 Approvals and Certifications ........38 Ring Topology..............22 31-00614-01 ® U.S. Registered Trademark Copyright © 2024 Honeywell Inc. • All Rights Reserved...
  • Page 2 HONEYWELL UNITARY INSTALLATION INSTRUCTIONS-24 VAC/VDC WEEE Directive 2012/19/EC Waste Electrical 10 K NTC TYPE III Characteristics....43 and Electronic Equipment directive ...... 38 10 K3A1 Characteristics........44 20 K NTC Characteristics........46 Article 33 Communication ........38 Nickel Class B DIN 43760 Sensors....50 Appendix ..............
  • Page 3: General

    (UIO) points, and solid state relays (SSR) and normal relays. • BACnet™ is a registered trademark of ASHRAE Inc. • Sylk™ is a trademark of Honeywell International Inc. These BACnet™ IP or BACnet™ MS/TP based Unitary controllers utilize smart engineering, commissioning Product Description tools, and Sylk™...
  • Page 4: Controller Part Numbers

    HONEYWELL UNITARY INSTALLATION INSTRUCTIONS-24 VAC/VDC Table 2 Accessories/Replacement Parts Part Number Description IP-T1L single pair media adapter that allows converting 10BASE-T traffic to 10BASE-T1L 10BASE-T1L-ADAPT (with power supply) IP-T1L single pair media adapter that allows converting 10BASE-T traffic to 10BASE-T1L...
  • Page 5: Unitary Controller Small

    • The Honeywell Unitary controllers must be installed and mounted by authorized and trained personnel. • In the case of any modification, except by Honeywell, the operation and safety warranties become void. • Observe all applicable local standards and regulations.
  • Page 6: Specifications

    HONEYWELL UNITARY INSTALLATION INSTRUCTIONS-24 VAC/VDC SPECIFICATIONS Table 4 Operational Environment Pollution Level 2 Electrical Hardware Table 3 Electrical Specification Table 5 Hardware Specification Parameter Specification Parameter Specification Rated input voltage 20 - 30 VAC / 24 - 30 VDC Crossover processor NXP I.MRT, •...
  • Page 7: T1L Communication

    HONEYWELL UNITARY INSTALLATION INSTRUCTIONS-24 VAC/VDC T1L Communication Weight and Dimensions Table 7 T1L Specifications Table 9 Weight and Dimensions Parameter Specification Parameter Specification 10BASE-T1L Large - 8.5 x 4.79 x 2.1 inches (216 x Dimension 802.3cg-2019 Standard (L x W x H) 121.6 x 53 mm).
  • Page 8: Wire Gauge Range

    HONEYWELL UNITARY INSTALLATION INSTRUCTIONS-24 VAC/VDC Wire Gauge Range Table 14 Relays Number of 40000 cycles for contact A (NO) Table 11 Wire Gauge Range Automatic 6000 cycles for contact C (CO) Cycles Parameter Specification Type of disconnection or interruption provided by...
  • Page 9: Hardware Overview

    HONEYWELL UNITARY INSTALLATION INSTRUCTIONS-24 VAC/VDC HARDWARE OVERVIEW 24 VAC/VDC Solid State Universal BACnet™ IP Model Power Supply Relays (4x) Relays (4x) Inputs/Outputs (4x) Relay Output Jumper RJ45 Ethernet 1 RJ45 Ethernet 2 BACnet™ MS/TP Model Service Button Universal Inputs/Outputs (12x) Sylk™...
  • Page 10: Service Button

    HONEYWELL UNITARY INSTALLATION INSTRUCTIONS-24 VAC/VDC Service Button IMPORTANT: Fig. 4 shows the hardware overview with the location of   US requirement, only: This device must be the service button, not the dedicated events. It is installed in a UL-listed enclosure offering...
  • Page 11: Wall Mounting

    HONEYWELL UNITARY INSTALLATION INSTRUCTIONS-24 VAC/VDC 3. Hold the controller as shown in below image and 3. Remove the controller from the wall and drill four mount the controller onto the DIN rail. holes at the marked locations. 8 19 21 22 23...
  • Page 12: Power Supply

    To prevent a risk of short-circuiting and damage to your Honeywell Unitary controllers, do not NOTE: reverse the polarity of the power connection cables and...
  • Page 13: Power Wiring Examples

    HONEYWELL UNITARY INSTALLATION INSTRUCTIONS-24 VAC/VDC Power Wiring Examples Power wiring example for one controller per transformer UL Listed Class 2 Transformer 24 VAC / VDC 120/240 Max. 100 VA Earth Ground 37 38 Unitary controller 37 38 NC1 NO1 IN1 NC2 NO2 IN2 NC3 NO3 IN3 NC4 NO4 IN4...
  • Page 14: Input / Output Wiring

    HONEYWELL UNITARY INSTALLATION INSTRUCTIONS-24 VAC/VDC INPUT / OUTPUT WIRING Wiring Requirements NOTE: When attaching two or more wires to the same terminal, other than 14 AWG (2.0 mm ), be sure to twist them together. Deviation from this rule can result in improper electrical contact.
  • Page 15: Internal Wiring Examples

    HONEYWELL UNITARY INSTALLATION INSTRUCTIONS-24 VAC/VDC Internal Wiring Examples Internal Wiring Large controller Factory Jumper 24 VDC or VAC 21 22 23 37 38 21 22 23 37 38 NC1 NO1 IN1 NC2 NO2 IN2 NC3 NO3 IN3 NC4 NO4 IN4...
  • Page 16 HONEYWELL UNITARY INSTALLATION INSTRUCTIONS-24 VAC/VDC Internal Wiring Small controller Factory Jumper 24 VDC or VAC SRIN NC1 NO1 IN1 NC2 NO2 IN2 NC3 NO3 IN3 NC4 NO4 IN4 POWER 24V DO RELAY DO SSR MS/TP 1 RS485 1 POW24 SYLK...
  • Page 17: Terminal Connections

    HONEYWELL UNITARY INSTALLATION INSTRUCTIONS-24 VAC/VDC Terminal Connections Table 16 Terminal Connections Terminal Label Description POWER 24V Building earth ground   24 VAC / VDC power input 24 VAC / VDC power input   DO RELAY Relay normally Closed 1 Relay normally Open 1...
  • Page 18 HONEYWELL UNITARY INSTALLATION INSTRUCTIONS-24 VAC/VDC Table 16 Terminal Connections Terminal Label Description T1L Switch 2 T1L Switch 2 Common BACnet MS/TP Model BACnet MS/TP positive BACnet MS/TP negative SHLD BACnet MS/TP shield RS485 1 RS485 Modbus positive RS485 Modbus negative...
  • Page 19: Uio Wiring Examples

    HONEYWELL UNITARY INSTALLATION INSTRUCTIONS-24 VAC/VDC UIO Wiring Examples 11 12 13 14 15 17 18 19 21 22 23 32 33 34 35 36 37 38 11 12 13 14 15 17 18 19 21 22 23 32 33 34 35 36 37 38...
  • Page 20: Ssr (Do) Wiring Examples

    HONEYWELL UNITARY INSTALLATION INSTRUCTIONS-24 VAC/VDC SSR (DO) Wiring Examples 11 12 13 14 15 17 18 19 21 22 23 32 33 34 35 36 37 38 11 12 13 14 15 17 18 19 21 22 23 32 33 34 35 36 37 38...
  • Page 21: Auxiliary Wiring Examples

    HONEYWELL UNITARY INSTALLATION INSTRUCTIONS-24 VAC/VDC Auxiliary Wiring Examples 11 12 13 14 15 17 18 19 21 22 23 32 33 34 35 36 37 38 11 12 13 14 15 17 18 19 21 22 23 32 33 34 35 36 37 38...
  • Page 22: Network Concepts

    Between Conductors (60 pF per meter) and Shield The Honeywell tested and recommended MS/TP cable is Honeywell Cable 3322 (18 AWG, 1-Pair, Shielded, Multi-Port (RSTP) Plenum cable). Alternatively, Honeywell Cable 3251 Ethernet Switch (22 AWG, 1-Pair, Shielded, Plenum cable) is available and meets the BACnet™...
  • Page 23: Bacnet™ Ip Controller

    Windows computer. controller will acquire a new IP address from the server and start using it immediately. Connecting to an IP network Honeywell Unitary controllers communicate over wired IPv4 network using Ethernet connection via two RJ45 ports. DHCP IP Configuration A new controller from the factory has DHCP enabled by default.
  • Page 24: Bacnet™ Ms/Tp Wiring

    9.6, match the rated characteristic impedance of the 19.2, 38.4, 57.6, and 76.8 kbps. The Honeywell Unitary installed cable. For example, if the installed MS/TP controller BACnet™ MS/TP are server devices on the cable has a listed characteristic impedance of 120 Ω,...
  • Page 25: Bacnet™ Ms/Tp Wiring Example

    HONEYWELL UNITARY INSTALLATION INSTRUCTIONS-24 VAC/VDC BACnet MS/TP Wiring Example BACnet MS/TP CONTROLLER BACnet MS/TP CONTROLLER BACnet MS/TP CONTROLLER Shield SHLD SHLD SHLD RS485 RS485 RS485 Reference Shield PLANT CONTROLLERS Fig. 22 Connection to a BACnet™ MS/TP Bus NOTE: • Suppose any of the devices are electrically isolated. It is recommended that those devices be connected to the ground terminal (SHLD).
  • Page 26: Bacnet™ Ms/Tp Controller

    The MS/TP MAC address for each device must be set to a unique value in the range of 1-127 on an MS/TP In contrast to other controllers, the Honeywell Unitary network segment (addresses 1, 2, & 3 should be avoided controller features automatic MAC addressing.
  • Page 27: Set The Device Instance Number

    MAC address would be 85 (1 + 4 + 16 + 64 = 85). All ON All OFF Fig. 25 MS/TP MAC Address Details To set the MAC address of a Honeywell Unitary controller BACnet™ MS/TP: = 85 1. Find an unused MAC address on the BACnet™...
  • Page 28: T1L Communication Standard

    STP loop is 39 with one switch. communicate on low-cost single twisted pair cable within an IP network. It reduces the cost of the installation of these devices. Through the Honeywell T1L media adapter, T1L networks can be connected to T1L RSTP Ring Topology main IP networks by converting one media type to another.
  • Page 29: Modbus Rtu

    Modbus RS-485 Repeaters RS-485 repeaters are possible but have not been tested The controller features a removable 2-wire with shield, by Honeywell; therefore, it is the installing or non-isolated, RS-485 interface suitable for Modbus commissioning person's responsibility to ensure proper communication (terminals 45, 46, and 47).
  • Page 30: Modbus Considerations

    HONEYWELL UNITARY INSTALLATION INSTRUCTIONS-24 VAC/VDC Modbus Considerations The RS-485 interface suitable for Modbus communication is 2-wire with shield non-isolated, hence the following considerations apply: • Maximum Modbus length (“L”): 4000 feet (1200 meters) for 9.6 – 78.8 kbps or 2600 feet (790 meters) for 115.2 kbps. It is recommended that you select a low baud rate (for example, 19.2 kbps) for reliable operation.
  • Page 31: Sylk

    The workbench software has a built-in resource calculator to determine the number of Sylk™ wall modules. The following are the Sylk™ wall modules and Sylk™ actuators supported by the Honeywell Unitary controller. Supported Sylk™ devices • Sylk™ wall modules: TR42, TR42-H, TR42-CO2,...
  • Page 32: Sylk™ Wiring Example

    HONEYWELL UNITARY INSTALLATION INSTRUCTIONS-24 VAC/VDC Sylk™ Wiring Example 11 12 13 14 15 17 18 19 21 22 23 32 33 34 35 36 37 38 11 12 13 14 15 17 18 19 21 22 23 32 33 34 35 36 37 38...
  • Page 33: Troubleshooting

    HONEYWELL UNITARY INSTALLATION INSTRUCTIONS-24 VAC/VDC TROUBLESHOOTING The Honeywell Unitary controller features a Service Button, Status LED, Power LED, and two additional LEDs (T1 and R1) for commissioning and troubleshooting. Check if the Status LED's behavior is changed if you switch the power OFF/ON. If this does not solve the problem, contact your reseller.
  • Page 34: Led Interface

    HONEYWELL UNITARY INSTALLATION INSTRUCTIONS-24 VAC/VDC LED Interface BACnet IP Model MODBUS LED SERVICE PIN LED STATUS LED SERVICE BUTTON LED BACnet MS/TP Model MS/TP LED MODBUS LED STATUS LED SERVICE PIN LED SERVICE BUTTON LED BACnet T1L Model T1L LED...
  • Page 35: Bluetooth Led Status

    HONEYWELL UNITARY INSTALLATION INSTRUCTIONS-24 VAC/VDC Bluetooth LED Status Table 24 Bluetooth LED Status LED Status Visual Mode BLE disabled Green LED BLE normal operation and connected permanent ON Green LED, 2 blinks in 1 sec followed by BLE enabled but not connected...
  • Page 36: T1L Led Status

    HONEYWELL UNITARY INSTALLATION INSTRUCTIONS-24 VAC/VDC T1L LED Status Table 27 T1L LED Status LED Status Visual Mode Green LED Link is up, Valid IP address is configured. permanent OFF Communication is healthy. Yellow LED Link is up, no valid IP address is configured.
  • Page 37: Regulatory Information

    HONEYWELL UNITARY INSTALLATION INSTRUCTIONS-24 VAC/VDC REGULATORY INFORMATION interference that may cause undesired operation of the device. FCC Regulation This device complies with the Canadian ICES-003 Class B specifications. CAN ICES-003(B) / NMB-003 (B). This device complies with Part 15 of the FCC Rules.
  • Page 38: Ce Statement

    Concerning the Registration, Evaluation, Authorization, and Restriction of Chemicals (REACH) Honeywell takes compliance with REACH very seriously. According to Article 33, “Duty to communicate information on substances in articles”: • Any supplier of an article containing a substance Fig.
  • Page 39: Appendix

    HONEYWELL UNITARY INSTALLATION INSTRUCTIONS-24 VAC/VDC APPENDIX Sensor Input Accuracy The controller's internal sensor inputs support both 10 K NTC Ω and 20 K NTC Ω sensors. The following table lists the typical minimum accuracies of the hardware and software for these temperature sensors.
  • Page 40: Recognition Of Sensor Failure Of Sensor Inputs

    HONEYWELL UNITARY INSTALLATION INSTRUCTIONS-24 VAC/VDC Recognition of Sensor Failure of Sensor Inputs The thresholds at which the sensor fails, that is, sensor breaks (SB) and short-circuits (SC), are recognized, depending upon the given sensor type. In the event of a recognized sensor failure, the sensor assumes the safety values configured in Table 32 on page 39.
  • Page 41: Sensor Characteristics

    HONEYWELL UNITARY INSTALLATION INSTRUCTIONS-24 VAC/VDC Sensor Characteristics The characteristics (resistance in relation to temperature) of the sensors and the resultant voltage are listed on the following pages. The stated values do not include failures due to sensor failures, wiring resistance or wiring failures, mis readings due to a meter connected to measure resistance or voltage at the input.
  • Page 42 HONEYWELL UNITARY INSTALLATION INSTRUCTIONS-24 VAC/VDC Table 34 10 K NTC TYPE II Characteristics (Continued) Terminal Terminal Temp. Temp. Resistance Temp. Temp. Resistance Voltage Voltage [°F] [°C] [KΩ] [°F] [°C] [KΩ] 33.8 31.027 5.189 91.4 7.098 2.159 93.2 6.808 2.091 159.8 1.694...
  • Page 43: 10 K Ntc Type Iii Characteristics

    HONEYWELL UNITARY INSTALLATION INSTRUCTIONS-24 VAC/VDC 10 K NTC TYPE III Characteristics Table 35 10 K NTC TYPE III Characteristics Temp. Temp. Temp. [°F] Resistance [Ω] Temp. [°F] Resistance [Ω] [°C] [°C] -37.2 203.6K 40.6 5479 -34.4 173.6K 43.3 4947 -31.7 148.3K...
  • Page 44: 10 K3A1 Characteristics

    HONEYWELL UNITARY INSTALLATION INSTRUCTIONS-24 VAC/VDC 10 K3A1 Characteristics Table 36 10 K3A1 Characteristics Temp. Temp. Resistance Temp. Temp. Resistance [°F] [°C] [Ω] [°F] [°C] [Ω] 336098 26.6 38110 -38.2 314553 28.4 36184 -36.4 294524 30.2 34366 -34.6 275897 32651 -32.8 258563 33.8...
  • Page 45 HONEYWELL UNITARY INSTALLATION INSTRUCTIONS-24 VAC/VDC Table 36 10 K3A1 Characteristics (Continued) Temp. Temp. Resistance Temp. Temp. Resistance [°F] [°C] [Ω] [°F] [°C] [Ω] 42317 89.6 7402 24.8 40151 91.4 7097 93.2 6807 159.8 1693 6530 161.6 1637 96.8 6266 163.4 1582 98.6...
  • Page 46: 20 K Ntc Characteristics

    HONEYWELL UNITARY INSTALLATION INSTRUCTIONS-24 VAC/VDC Table 36 10 K3A1 Characteristics (Continued) Temp. Temp. Resistance Temp. Temp. Resistance [°F] [°C] [Ω] [°F] [°C] [Ω] 156.2 1813 222.8 1752 224.6 226.4 242.6 228.2 244.4 246.2 231.8 233.6 249.8 235.4 251.6 237.2 253.4 255.2...
  • Page 47 HONEYWELL UNITARY INSTALLATION INSTRUCTIONS-24 VAC/VDC Table 37 20 K NTC Characteristics (Continued) Temp. Temp. Resistance Terminal Temp. Temp. Resistance Terminal [°F] [°C] [KΩ] voltage [V] [°F] [°C] [KΩ] Voltage [V] -20.2 8.41 42.8 51.1 -18.4 8.38 44.6 48.5 -16.6 8.35 44.4...
  • Page 48 HONEYWELL UNITARY INSTALLATION INSTRUCTIONS-24 VAC/VDC Table 37 20 K NTC Characteristics (Continued) Temp. Temp. Resistance Terminal Temp. Temp. Resistance Terminal [°F] [°C] [KΩ] voltage [V] [°F] [°C] [KΩ] Voltage [V] 109.4 8.98 2.57 174.2 2.24 0.818 111.2 8.61 2.49 2.17 0.792...
  • Page 49 HONEYWELL UNITARY INSTALLATION INSTRUCTIONS-24 VAC/VDC Table 37 20 K NTC Characteristics (Continued) Temp. Temp. Resistance Terminal Temp. Temp. Resistance Terminal [°F] [°C] [KΩ] voltage [V] [°F] [°C] [KΩ] Voltage [V] 240.8 0.68 0.266 0.31 0.122 242.6 0.66 0.259 294.8 0.119 244.4...
  • Page 50: Nickel Class B Din 43760 Sensors

    HONEYWELL UNITARY INSTALLATION INSTRUCTIONS-24 VAC/VDC Nickel Class B DIN 43760 Sensors T(R) = a´+b´(1+c´R)½ +d´R5+e´R7 dT < 0.12 K (higher order equations on request) The characteristic of the nickel temperature sensor is specified as per DIN 43760. The large Temperature...
  • Page 51: Ni1000 Tk5000 Din B

    HONEYWELL UNITARY INSTALLATION INSTRUCTIONS-24 VAC/VDC NI1000 TK5000 DIN B R-T Characteristics of Ni1000 TK5000 DIN B. Table 39 NI1000 TK5000 Sensor Specification Sensor Type Nominal Resistance Sensitivity : 1000 Ω Ni1000 TK5000 DIN B TC: 5000 ppm/K Table 40 R-T Characteristics (according to supplier‘s specifications and based on DIN 43760, resistance values in Ω)
  • Page 52: Pt100 Characteristics

    HONEYWELL UNITARY INSTALLATION INSTRUCTIONS-24 VAC/VDC PT100 Characteristics Table 41 PT100 Characteristics Temp. [°F] Temp.[°C] Resistance [Ω] -34.44 -28.89 -23.33 -17.78 -12.22 -6.67 -1.11 0.00 4.44 10.00 15.56 21.11 25.00 26.67 32.22 37.78 43.33 48.89 54.44 60.00 65.56 71.11 76.67 82.22 87.78...
  • Page 53: Pt1000 Characteristics

    HONEYWELL UNITARY INSTALLATION INSTRUCTIONS-24 VAC/VDC PT1000 Characteristics Table 42 PT1000 Characteristics Terminal Temp. Temp. Resistance Terminal Temp. Temp. Resistance Voltage [°F] [°C] [KΩ] Voltage [V] [°F] [°C] [KΩ] 0.312 0.367 -56.2 0.314 10.4 0.369 -54.4 0.315 12.2 0.37 -52.6 0.317 0.372...
  • Page 54 HONEYWELL UNITARY INSTALLATION INSTRUCTIONS-24 VAC/VDC Table 42 PT1000 Characteristics (Continued) Terminal Temp. Temp. Resistance Terminal Temp. Temp. Resistance Voltage [°F] [°C] [KΩ] Voltage [V] [°F] [°C] [KΩ] 75.2 1093 0.42 145.4 1244 0.476 1097 0.422 147.2 1248 0.477 78.8 1101 0.423...
  • Page 55 HONEYWELL UNITARY INSTALLATION INSTRUCTIONS-24 VAC/VDC Table 42 PT1000 Characteristics (Continued) Terminal Temp. Temp. Resistance Terminal Temp. Temp. Resistance Voltage [°F] [°C] [KΩ] Voltage [V] [°F] [°C] [KΩ] 143.6 1240 0.474 213.8 1389 0.528 215.6 1393 0.53 1536 0.581 217.4 1396 0.531...
  • Page 56 HONEYWELL UNITARY INSTALLATION INSTRUCTIONS-24 VAC/VDC Table 42 PT1000 Characteristics (Continued) Terminal Temp. Temp. Resistance Terminal Temp. Temp. Resistance Voltage [°F] [°C] [KΩ] Voltage [V] [°F] [°C] [KΩ] 282.2 1532 0.58 350.6 1674 0.63 352.4 1677 0.631 420.8 1817 0.68 354.2 1681 0.632...
  • Page 57 HONEYWELL UNITARY INSTALLATION INSTRUCTIONS-24 VAC/VDC Table 42 PT1000 Characteristics (Continued) Terminal Temp. Temp. Resistance Terminal Temp. Temp. Resistance Voltage [°F] [°C] [KΩ] Voltage [V] [°F] [°C] [KΩ] 1813 0.679 487.4 1952 0.727 489.2 1955 0.728 557.6 2092 0.775 1959 0.729 559.4...
  • Page 58 HONEYWELL UNITARY INSTALLATION INSTRUCTIONS-24 VAC/VDC Table 42 PT1000 Characteristics (Continued) Terminal Temp. Temp. Resistance Terminal Temp. Temp. Resistance Voltage [°F] [°C] [KΩ] Voltage [V] [°F] [°C] [KΩ] 555.8 2088 0.774 624.2 2223 0.82 2226 0.821 690.8 2353 0.863 627.8 2230 0.822...
  • Page 59: Pt3000 Characteristics

    HONEYWELL UNITARY INSTALLATION INSTRUCTIONS-24 VAC/VDC PT3000 Characteristics Table 43 PT3000 Characteristics Terminal Temp. Temp. Resistance Terminal Temp. Temp. Resistance Voltage [°F] [°C] [KΩ] Voltage [V] [°F] [°C] [KΩ] 2.82 1.02 3.74 1.31 2.87 1.03 3.78 1.32 2.91 1.05 3.83 1.33 2.96...
  • Page 60: Abbreviations

    The material in this document is for information purposes only. The content and the product described are subject to change without notice. Honeywell makes no representations or warranties with respect to this document. In no event shall Honeywell be liable for technical or editorial omissions or mistakes in this document, nor shall it be liable for any damages, direct or incidental, arising out of or related to the use of this document.

Table of Contents