Rack-Mounting Guidelines

Lightning and AC Power Fault Interference
As this product is safety certified for indoor connection only, if signal wires exceed recommended cabling
distances, you should consider the effect that a lightning strike in your vicinity might have on the controller.
The electromagnetic pulse (EMP) generated by lightning or other high-energy phenomena can couple enough
energy into unshielded conductors to damage or destroy electronic equipment. If you have previously
experienced such problems, you should consult with RFI/EMI experts to ensure that you have adequate
electrical surge suppression and shielding of signal cables in your controller operating environment.
Rack-Mounting Guidelines
This section describes guidelines on rack-mounting.
Precautions for Rack-Mounting
The following rack-mounting guidelines are provided to ensure your safety:
Warning
• Do not move large racks by yourself. Due to the height and weight of a rack, a minimum of two people
• Ensure that the rack is level and stable before extending a component from the rack.
• Ensure that proper airflow is provided to the components in the rack.
• Do not step or stand on any component or system when servicing other systems or components in a rack.
General Rack-Selection Guidelines
The Cisco Catalyst CW9800H1 Wireless Controller and Cisco Catalyst CW9800H2 Wireless Controller can
be mounted in most two-post or four-post, 19-in. equipment racks that comply with the Electronics Industries
Association (EIA) standard for equipment racks (EIA-310-D 19-in.). The rack must have at least two posts
with mounting flanges to mount the chassis.
Cisco Catalyst CW9800H1 and CW9800H2 Wireless Controllers Hardware Installation Guide
40
To prevent bodily injury when mounting or servicing this unit in a rack, you must take special
precautions to ensure that the system remains stable.
The following guidelines are provided to ensure your safety:
• This unit should be mounted at the bottom of the rack if it is the only unit in the rack.
• When mounting this unit in a partially filled rack, load the rack from the bottom to the top with
the heaviest component at the bottom of the rack.
• If the rack is provided with stabilizing devices, install the stabilizers before mounting or servicing
the unit in the rack.
Statement 1006
are required to accomplish this task.
Preparing Your Site for Installation