Page 2
The use of this documentation does not grant you a licence or any other right to use any name, logo or label referred to or depicted herein. This documentation is subject to the copyright of Honeywell. The content must not be copied, published, modified, distributed, transmitted, sold or changed without the express prior written permission of Honeywell.
6.4.2 Board Assembly MA-BST-C ..........................27 MA-2000 NETWORK WIRING EXAMPLE NODE-TO-NODE CONNECTION ..............28 MA-2000 Network Wiring Example Single CAN-BUS amplifier card installed on HLSPS25 EN 54-4 PSU ..................................28 MA-2000 Network Wiring Example Multiple CAN-BUS amplifier card installed on HLSPS25 EN 54-4 PSU ..................................29 COMMUNICATION LINES WITH DETECTORS / MODULES ......................
Page 4
MA-2000-0x Flat Cables Set (SKU 5000.00.005)......................... 44 11.4 MA-2000-0x Power supply, pre-mounted (SKU 5000.00.008) .................. 45 11.5 MA-2000-01 Main board + LCD (SKU: 5000.00.013) MA-2000-02 Main board + LCD (SKU: 5000.00.014) MA-2000-03 Main board + LCD (SKU: 5000.00.015) ....................... 46 M-167.1-MA2000-EN / 06.2022...
Peripheral devices (sensors, etc.) which are not perfectly compatible with the control unit may cause damage to the control unit or cause the system to malfunction at any time. It is therefore essential to only use material which is guaranteed by Honeywell and is compatible with its control units.
Test Condition Indication of the test condition 10.2 Indication of zones in the test state 10.3 • The power supply section of the MA-2000 control unit is in conformity with the following EN54 EN 54-4 requirements. Function EN 54-4 reference...
MA-2000 TRANSPORT DAMAGE INSPECTION Please check all of the packaging and components for damage before commencing the assembly and installation work. Do not assemble or install visibly damaged modules and components! Danger – Electrical shock! Remove all power from the FACP before carrying out any installation work!
2 Optional outputs with contacts free from voltage / supervised Output (EOL 4 7 KΩ or Diode) Mechanics The control unit mechanics is suitable for wall installations. For cabinet sizes refer to the below drawing “MA-2000 dimensions” • Protection grade: IP 30 •...
MA-2000 ASSEMBLY AND INSTALLATION INFORMATION The function of the FACP depends on the country-specific version of the operating system software used for the panel and the customer data programming. • Installation and commissioning must only be carried out by a qualified electrician! •...
Page 12
MA-2000 The control unit must be installed to the wall so as to allow a clear view of the display and easy access by the operator. For example, it allows an optimal view of the display at 1,5 m height.
4.2 MA-2000 Flush Mount MA-2000 panel can be flush mounted into a wall recess using a mounting kit MA-2BE: Step 1: create a recess in a wall into which the MAX panel is to be semi flush mounted. The Recess Depth Z1/Z2 must be such that there is clearance to allow door to work.
MA-2000 4.3 Labels for the control panel The control panel of the MA-2000 is equipped with pull-out labels that provide information about the functional status of the LED. A set of labels in different languages for self-printing is available in chapter 10 of this documentation.
MA-2000 SPECIFICATIONS • Ambient temperature: - 5 ° C … +40 °C • Storage temperature: - 10°C … +50°C • Relative humidity: 10 % … 95 % (without condensation) 5.1 Earthing The earthling system must be performed in conformity with CEI and ISPELS rules or rules valid in the country where the panel is installed.
MA-2000 5.4.2 Batteries Installation 5.4.3 Power supply and battery operation The main microprocessor of the control unit periodically checks the state of the main AC power supply source, batteries and the recharging circuit. The control unit will automatically switch on the stand-by battery source when AC mains fails.
MA-2000 5.4.4 Mains and Batteries connection IN 230 V AC IN 230V AC FUSE 230 V AC / 3,15 A The connection to the 230 V AC power supply mains must be performed through three-conductor cable (phase- neutral- earth). The identification of the earth conductor coming from the mains must be performed on the CN1 terminal block (refer to basic board topography) and must be fixed at the heart bar by means of cable –tightening strip so that...
MA-2000 SYSTEM COMPONENTS AW80US0 AW80PP1 AW80FR0 MA-2000 is equipped with: • PSU board AW80PP1 to connect the main. • Front board AW80FR0 that include LCD display 7" / 17,78 cm and the slot “Buttery Buffer RTC”. • Main connection board AW80US0 that includes connectors to front board and batteries.
MA-2000 6.1 MA-2000 CPU Board Board Setup Jumper housed on AW80Usx. Removing the JDSPE jumper causes the control panel JDSPE to ignore a ground fault on the control panel circuits, loop lines, and isolated CanBus lines. Removing the JDSPEA jumper causes the control unit to ignore an RS485-1 ground...
MA-2000 6.2.1 Terminal Board AW80US0 CNAL DC Power Supply Positive Earth It comes from power supply module – board AW70PP1 Negative Batteries Positive Battery 1 Negative Battery 1 Protection with two MFR700 series resettable fuses Positive Battery 2 Negative Battery 2...
MA-2000 6.3 Relay outputs FUNCTION CHARACTERISTICS Sounder 1 contact controlled by 24 Vcc / 1 A resistive USR2 Max 1 A resistive 30 V DC, NO / NC or supervised output 1 A Fused, selectable through Jumper JUSR2 (refer to basic board topography)
MA-2000 6.3.2 General Fault relay The General Fault relay is usually in energized state. It is de-energized in Fault condition. This output is available in free voltage. Contact range: max 30 V AC / DC, 1 A, Non-inductive loads 19 20 Setting of the general fault output with N.O.
Contact range: max 30 V AC / DC, 2 A, Non-inductive loads Selection of type of contact (Normally open, normally closed or supervised outputs) refer to Chapter 4.4.2. To program the activation of these outputs refer to MA-2000 Commissioning Manual. USR1...
MA-2000 6.3.5 Sounder connection - controlled output Sounder output connections (refer to basic board topography) 1 A resettable fuse Polarized devices balanced with diode (electronic sirens, etc.) Connect the diode only on last sounder of the line. 1N4004 Polarity displayed are in...
MA-2000 6.4 OPTIONAL CARD 6.4.1 MA-BST-C (CAN-BUS amplifier card) This card can be installed in a remote HLSPS25 (power supply) in the CAN-BUS network to double the distance from node to node. Up to 8 MA-BST-C cards can be installed in the CAN-BUS network.
CONNECTION max. 500 m max. 500 m max. 500 m max. 500 m 7.1 MA-2000 Network Wiring Example Single CAN-BUS amplifier card installed on HLSPS25 EN 54-4 PSU max. 500 m max. 500 m max. 500 m M-167.1-MA2000-EN / 06.2022...
MA-2000 7.2 MA-2000 Network Wiring Example Multiple CAN-BUS amplifier card installed on HLSPS25 EN 54-4 PSU max. 500 m max. 500 m max. 500 m max. 500 m max. 500 m max. 500 m On the CAN-BUS network, it’s possible to install max. 8 of MA-BST-C cards...
Input Modules The addressable inputs modules allow the MA-2000 system to monitor contacts, manual alarm call points, 4 wires conventional detectors, and several other devices with alarm contact outputs.
MA-2000 8.1 Screen Termination Good quality fire industry cable must be used incorporating drain wires or screens. The drain wires or screens must be earthed within the enclosure. Cable screen or drain wire and earthing points. Ensure the drain wires or screens are adequately grounded inside the enclosure - earthing points are provided for this purpose on enclosure to cover all the cable entry points.
MA-2000 8.2 Test procedure for detection lines Before powering the control unit lines, check the following values: DIGITAL MULTI METER IS REQUIRED. Line resistance Positive Side B Negative Side A The direct current resistance of the negative wire of the loop SHALL NOT exceed 20 Ohm.
MA-2000 8.3 System Test and Commissioning The Control unit installation must be performed after having carefully read the instructions contained in the installation manual and the programming manual. Once mechanical installation of the control unit has been completed, perform the following operations: Check the correct detection line wiring through a multi-meter (refer to chapter Test Procedure for the analogue system lines in this manual).
Use the arrow keys to select the item “LED” (lamp test function), press the enter key to perform the test, check that all light indications are on for some seconds. 1. Disconnect the 230 V AC mains supply from the MA-2000 control unit and check the following conditions: •...
MA-2000 10 LABELS IN DIFFERENT LANGUAGES In this chapter labels in different languages are shown for the control panel of the MA-2000, which can be printed 1:1. • Print the labels in original size, pay attention to the printer settings.
MA-2000 11 SPARE PARTS Description Part No. User board 5000.00.003 Flat Cables 5000.00.005 Power Supply 5000.00.007 Main board + LCD, Version 01 5000.00.010 Main board + LCD, Version 02 5000.00.011 Main board + LCD, Version 03 5000.00.012 Front door 5000.00.017 Warning! These instructions must be studied carefully and understood before the replacement of spare parts.
MA-2000 The following information applies to all spare parts listed in this documentation: 11.1 Preparation 1. Disconnect the control panel completely from the mains voltage! 2. Switch off the fuse (main power). 3. Remove the 2 screws and open the panel door.
MA-2000 11.2 MA-2000-0x User board (SKU 5000.00.003) Preparation Be sure to follow the instructions 1 – 8 under "Preparation" in chapter 11.1! 1. Unplug all flat cable shown in chapter 11.3. 2. Remove the 4 screws and remove the board .
MA-2000 11.3 MA-2000-0x Flat Cables Set (SKU 5000.00.005) Preparation Be sure to follow the instructions 1 – 8 under "Preparation" in chapter 11.1! Unplug all flat cable + from the board . If necessary, the battery probe can be replaced at the same time.
MA-2000 11.4 MA-2000-0x Power supply, pre-mounted (SKU 5000.00.008) Preparation Be sure to follow the instructions 1 – 8 under "Preparation" in chapter 11.1! 1. Unplug all flat cable see chapter 11.3. 2. Unplug Earth cable from the housing. 3. Unscrew the spacers and remove the metal bracket from .
MA-2000 11.5 MA-2000-01 Main board + LCD (SKU: 5000.00.013) MA-2000-02 Main board + LCD (SKU: 5000.00.014) MA-2000-03 Main board + LCD (SKU: 5000.00.015) This spare part set includes Main board + LCD pre-mounted and firmware installed. Preparation Be sure to follow the instructions 1 – 8 under "Preparation" in chapter 11.1! Unplug both 50 poles flat cable ...
Page 47
MA-2000 Unscrews the 5 screws . Remove the main board + LCD lifting up using both hands. Reinstallation Install the new main board + LCD on front door. Follow the instructions in this chapter in reverse order, then follow the preparation instructions in chapter 11.1 in reverse order to step 8.