Configuring the Server Switch Module
Click Cisco InfiniBand Switch Module for IBM BladeCenter to obtain the operating system
Step 5
TopspinOS v2.6.0.
The software is an ISO image.
Burn the ISO image onto a CD.
Step 6
The ISO image contains the latest switch operating system software, release notes and other
documentation.
Configuring the Server Switch Module
To configure the Cisco InfiniBand Server Switch Module, follow these steps:
Open the BladeCenter Chassis Manager log-in screen by launching a Web browser and entering the IP
Step 1
address of the BladeCenter chassis in the address bar.
Log in.
Step 2
The BladeCenter Chassis Manager interface appears.
Expand I/O Module Tasks in the left-hand navigation tree.
Step 3
Select Management under I/O Module Tasks in the left pane.
Step 4
An I/O Module Management heading appears in the display.
Click the link of the physical slot that holds the Server Switch Module that you want to configure.
Step 5
A heading appears, where X is the number of the slot.
Step 6
Enter an IP address for the Server Switch Module in the IP address field of the New Static IP
Configuration section.
Note
Enter a subnet mask or the Server Switch Module in the Subnet mask field of the New Static IP
Step 7
Configuration section.
Note
Enter a gateway IP address for the Server Switch Module in the Gateway address field of the New Static
Step 8
IP Configuration section, and then click Save.
Note
Cisco 4x InfiniBand Switch Module for IBM BladeCenter User Guide
2-2
The IP address of the Server Switch Module must fall in the same subnet as the modules in the
other slots.
The subnet mask of the Server Switch Module must match the subnet mask of the modules in the
other slots.
The gateway address of the Server Switch Module must match the gateway address of the
modules in the other slots.
Chapter 2
Installing and Configuring the Server Switch