Cisco ASR 1002 Router Description
The DC power input connector euro-style terminal block will accept three wires: one positive polarity,
one negative polarity, and one earth ground wire. There is provisions on the front panel to wire tie and
strain relief the DC input wiring. The connection order shall be negative (–), positive (+), GND. The DC
power supply is secured into the system chassis with two captive screws mounted on the faceplate.
Figure 6-6
Figure 6-6
1
Chassis ESD socket
2
DC power supply slot 0 label
3
DC power supply switch Standby/On (I)
(standby symbol is a broken circle with a
vertical line through the top of it)
4
DC power supply LEDs
5
Fan
Cisco ASR 1000 Series Aggregation Services Routers Hardware Installation and Initial Configuration Guide
6-8
shows the DC Power Supply for the Cisco ASR1002 Router.
DC Power Supply for the Cisco ASR 1002 Router
1
2
3
4
OUTPUT INPUT
FAN
FAIL
OK
OK
0
This unit might have more than
one power supply connection.
All connections must be removed
to de-energize the unit.
-48V/-60V
16A
10
9
8
Chapter 6
Cisco ASR 1002 Router Overview and Installation
5
6
6
DC power supply captive installation screw
7
DC power supply slot 1 label
8
Earth ground lead
9
Positive lead
10 Negative lead
OUTPUT INPUT
FAN
FAIL
OK
OK
This unit might have more than
one power supply connection.
All connections must be removed
to de-energize the unit.
1
-48V/-60V
16A
7
OL-13208-03