hit counter script

AEG HKB75540NB User Manual page 8

Hide thumbs Also See for HKB75540NB:
Table of Contents

Advertisement

8
www.aeg.com
The rating plate is on the bottom of the
hob.
Model .......................................
PNC .........................................
Serial number ...........................
3.2 Important safety
requirements
This hob must be installed in accordance
with the Gas Safety (Installation and
Use) Regulations (Current Edition) and
the IEE Wiring Regulations (Current
Edition).
For appliances installed in the Republic
of Ireland please refer to NSAI- Domestic
Gas Installation I.S. 813 Current Editions
and the ETCI Rules for Electrical
Installations.
Provision for ventilation
Detailed recommendations are contained
in the following British Standards Codes
Of Practice: B.S. 6172/B.S. 5440, Par. 2
and B.S. 6891 Current Editions.
The hob should not be installed in a bed
sitting room with a volume of less than
20 m³. If it is installed in a room of
volume less than 5 m³ an air vent of
effective area of 100 cm² is required. If it
is installed in a room of volume between
5 m³ and 10 m³ an air vent of effective
area of 50 cm² is required, while if the
volume exceeds 11 m³ no air vent is
required.
However, if the room has a door which
opens directly to the outside no air vent
is required even if the volume is between
5 m³ and 11 m³.
If there are other fuel burning appliances
in the same room, B.S. 5440 Part 2
Current Edition, should be consulted to
determine the requisite air vent
requirements.
For appliances installed in the Republic
of Ireland please refer to the NSAI-
Domestic Gas Installation I.S. 813
Current Editions Table Four.
Location
The hob may be located in a kitchen, a
kitchen/diner or bed sitting room (with a
volume greater than 20 m³), but not in a
bathroom or shower room.
The minimum distance combustible
material can be fitted above the hob in
line with the edges of the hob is 400 mm.
If it is fitted below 400 mm a space of 50
mm must be allowed from the edges of
the hob.
For appliances installed in the Republic
of Ireland please refer to NSAI- Domestic
Gas Installation I.S 813 Current Edition
Section 7- Permitted Locations of
Appliance.
3.3 Gas Connection
WARNING!
Any gas installation must be
carried out by a GAS SAFE
REGISTER installer.
Please refer to the technical
instructions on how to adjust
the hob to the gas
specifications on Malta.
This appliance is certified for
Malta.
Make sure that, once the hob is installed,
it is easily accessible for the engineer in
the event of a breakdown.
The manufacturer will not accept liability,
should the above instructions or any of
the other safety instructions incorporated
in this instruction booklet be ignored.
On the end of the shaft, which includes
the R 1/2" threaded elbow, adjustment is
fixed so that the washer is fitted between
the components as shown in the
diagram. Screw the parts together
without using excessive force.
A
B C
A. End of shaft with nut
B. Washer supplied with the appliance

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hkb75nb540

Table of Contents