Updating or Expanding an Existing Installation

Adding or replacing modules in an existing installation requires the following
steps:
Step
1.
The installer logs on to MAXPRO Cloud and
switches to Installer Mode.
This will prevent trouble events going to the
central monitoring station during maintenance
work.
2.
The customer grants the installer access to the
system.
3.
The installer shuts down the control panel using
the SHUTDOWN button.
This makes sure that the system can save all
necessary data and statuses in the flash
memory. It disables the inputs and outputs, but
does not remove power (from the AC power
supply or the batteries).
4.
The installer adds, removes, or replaces the
required modules.
5.
The installer restarts the control panel by
pressing the SHUTDOWN button.
6.
The installer registers and configures the new
peripheral devices in MAXPRO Cloud.
7.
The installer tests and commissions the system.
UL
When making changes to an existing system, there must be
someone present on site for testing when powering up the system
again or downloading configurations. Never change any
configuration settings or upload firmware unless someone is there to
test.
800-23044 Rev.  A draft_11
Installation and Setup Guide
For details, see...
MAXPRO Cloud
online help
MAXPRO Intrusion
User Guide (doc. no.
800-23041).
Shutting Down the
Panel Securely on
page 122.
For swapping
devices, see
Swapping Devices
on page 24.
Configuration in
MAXPRO Cloud on
page 124.
Testing and
Commissioning on
page 142.
23

Advertisement

Table of Contents
loading

This manual is also suitable for:

Maxpro mpip3000u seriesMaxpro mpip2100uMaxpro mpip3000u

Table of Contents