Honeywell MAXPRO Intrusion MPIP2000U/3000U Series
Feature
Access
Programming
Schedules
Holidays (per year)
Controller rules
Bus Network
On-board IB2 data bus lines
On-board V-Plex sensor bus lines
Power Supply
Max. constant current
Battery charging capacity
Communication Paths
IP/Ethernet
Radio communication (4G/LTE)
Central Station Signalling Protocols
Contact ID
SIA
AlarmNet via AlarmNet services
2.2.2

Inputs and Output

Provides 10 on-board hardwire zones.
l
Supports up to 16 two-wire smoke detectors on zones 9 and 10 (32 in
l
total).
Four-wire smoke detector reset through use of on-board relay.
l
Low-voltage trigger outputs.
l
Outputs can be programmed to activate in response to system events
l
(alarm condition), or at a specific time of day, or manually.
Provides up to three emergency keys on the keypads (configurable per
l
area).
Battery sensing hardware that monitors two batteries independently and
l
can sense when either battery voltage is too low. Prevents deep discharge
from occurring.
1
With the MPI medium-sized cabinet (MPIBXM35), you can use a battery capacity of up to
18  Ah. If you need more battery capacity, you need to install a second tamper-protected
cabinet with the second battery.
800-23044 Rev.  A draft_11
1
Installation and Setup Guide
MPIP2100U MPIP3000U
10,000
10,000
50
100
40
40
50
100
1
2
1
2
3.0 A
3.0 A
36 Ah
36 Ah
1 on board
1 on board
Optional
Optional
15