®
Gas Washer/Dryer
PRODUCT MODEL NUMBER
LTG6234D
Gas supply:
Dryer is equipped for use with
NATURAL gas. Dryer can be converted to L.P. gas.
When rigid pipe is used it should be 1/2 inch IPS.
When acceptable to the gas supplier and local
codes, 3/8-inch approved tubing may be used for
lengths under 20 feet. For lengths over 20 feet,
larger tubing should be used. This washer/dryer is
equipped with its own permanent, flexible gas
connector, design-certified by CSA International,
for connecting the appliance to the gas supply line.
An individual manual shutoff valve must be
installed within 6 feet of the dryer in accordance
with the National Fuel Gas Code ANSI
Z223.1/NFPA 54.
Electrical: A
120-volt, 60-Hz., AC-only, 15- or
20-amp, fused electrical supply is required. A
time-delay fuse or circuit breaker is recommended.
It is also recommended that a separate circuit
serving only this appliance be provided.
Exhaust venting: Exhaust your dryer to the
outside. Four-inch diameter vent is required. Rigid
or flexible metal exhaust vent must be used. Do
not use plastic or metal foil vent. Exhaust outlet
hood must be at least 12 inches from the ground
or any object that may be in the path of the
exhaust. The dryer can be converted to exhaust
out right or left side.
EXHAUST VENTING
Plan installation to use the fewest number of elbows
and turns.
Maximum length of the exhaust system depends
upon the type of vent used, number of elbows and
the type of exhaust hood. The maximum length for
both rigid and flexible vent is shown in the chart.
4"
(10.2 cm)
(6.4 cm)
Angled hood style
Vent Length Chart
No. of
Type of Vent
Box or
90° turns
Louvered
or elbows
hoods
0
Rigid metal
37 ft (11.3 m)
Flexible metal
25 ft (7.6 m)
1
Rigid metal
32 ft (9.7 m)
Flexible metal
21 ft (6.4 m)
2
Rigid metal
24 ft (7.3 m)
Flexible metal
15 ft (4.6 m)
NOTE: Side and bottom exhaust adds a 90 turn inside the
xi
washer/dryer. To determine maximum exhaust length, add one
°
90 turn to the chart.
Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.
OVERALL DIMENSIONS
* Most installations require a
minimum 5 " (14 cm) clearance
behind the dryer for the exhaust
vent with elbow.
RECESSED AREA AND CLOSET INSTALLATION
Additional clearances might be required for wall, door and floor moldings.
Rear clearance may be 0" when house exhaust system is lined up directly with dryer exhaust.
B
(2.5 cm)
2
A
1
4"
(10.2 cm)
DRAIN SYSTEM
4"
(10.2 cm)
A. Louvered hood style
1. Louvered hood style
B. Box hood style
2. Box hood style
Angled
hoods
35 ft (10.7 m)
20 ft (6.1 m)
27 ft (8.2 m)
16 ft (4.9 m)
19 ft (5.8 m)
10 ft (3.0 m)
°
71 "
(181.9 cm)
*32"
(81.3 cm)
A
B
1"
27"
1"
1"
32"
(68.6cm)
(2.5cm)
(2.5 cm)
(81.3 cm)
A. Recessed area
B. Side view - closet or confined area
C. Closet door with vents
Standpipe drain system - wall or floor
The standpipe drain requires a minimum diameter standpipe of 2" (5 cm). The minimum carry-away
capacity can be no less than 17 gal. (64 L) per minute. A 2" (5 cm) diameter to 1" (2.5 cm) diameter
standpipe adapter kit is available.
The top of the standpipe must be at least 39" (99 cm) high and no higher than 96" (2.4 m) from the
bottom of the washer.
Laundry tub drain system
The laundry tub needs a minimum 20 gal. (76 L) capacity. The top of the laundry tub must be at least
34" (86.4 cm) above the floor and no higher than 96" (2.4 m) from the bottom of the washer.
Floor drain system
The floor drain system requires a siphon break that may be purchased separately.
The siphon break must be a minimum of 28" (71 cm) from the bottom of the washer. Additional hoses
might be needed.
Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.
23 "
(60.3 cm)
32 "
(81.9 cm)
27"
(68.6 cm)
C
6"
3"
(15.2 cm)
(7.6 cm)
48 in.
2
(310 cm
2
)
24 in.
2
3"
(155 cm
2
)
(7.6 cm)
5 "
(14 cm)
Ref. 8572777 Rev. A
12-12-05