Product Overview
1
2
3
4
5
Digital I/O Connector
The Digital I/O connector has 4 GPIO connections plus 1 Return connection. The Digital I/O supports Both
Dry and Wet contacts up to 60Volts.
• Dry contact is isolated from a voltage source (or "No Volt"), with an embedded relay function (NPN
• Wet contact is a contact with external power (+3.3V to +60V, max 150mA of current allowed at high
Figure 7
Note
Digital I/O is only supported on IOS-XE version 16.12.1 and above.
Note
The default state of the Digital I/O is input, the open-collector is open (off).
Figure 7: Digital I/O connector
The pinouts for the Digital I/O are described in
Table 2: Digital I/O Pinouts
Pin #
1
2
3
4
transistor), usually used to indicate an event. For example: open/close, alarm.
voltage) applied, usually used to energize something. For example: solenoid, light.
shows the connector.
Name
DIO1
DIO2
DIO3
DIO4
4 GPIO + 1 Return (Digital I/O)
SFP Connector
Pluggable Module
mSATA SSD Slot
Digital I/O LEDs
Table 2
.
Direction
I/O
I/O
I/O
I/O
Digital I/O Connector
Description
Digital IO 1
Digital IO 2
Digital IO 3
Digital IO 4