hit counter script
Siemens SIMATIC IPC127E Operating Instructions Manual

Siemens SIMATIC IPC127E Operating Instructions Manual

Firmware/bios description
Hide thumbs Also See for SIMATIC IPC127E:

Advertisement

Firmware/BIOS description SIMATIC
IPC127E
SIMATIC
Industrial PC
Firmware/BIOS description
SIMATIC IPC127E
Operating Instructions
01/2019
A5E45911216-AA
Firmware/BIOS descrip-
_______________________
Important information
Using the firmware selection
_______________________
_______________________
menu
_______________________
_______________________
Configure firmware
_______________________
_______________________
Update firmware
_______________________
_______________________
Booting from USB stick
Enable Trusted Platform
_______________________
_______________________
Module (TPM)
Automatic switching on of
____________
the device
1
2
3
4
5
6

Advertisement

Table of Contents
loading

Summary of Contents for Siemens SIMATIC IPC127E

  • Page 1 _______________________ _______________________ SIMATIC Configure firmware _______________________ _______________________ Update firmware Industrial PC Firmware/BIOS description _______________________ _______________________ Booting from USB stick SIMATIC IPC127E Enable Trusted Platform _______________________ _______________________ Module (TPM) Operating Instructions Automatic switching on of ____________ the device 01/2019 A5E45911216-AA...
  • Page 2 Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
  • Page 3: Important Information

    The firmware (BIOS) is located in a FLASH block on the motherboard. The firmware selection menu can be opened after the device has been started. You can then configure the firmware settings of your device. Firmware/BIOS description SIMATIC IPC127E Operating Instructions, 01/2019, A5E45911216-AA...
  • Page 4 Siemens' products and solutions undergo continuous development to make them more secure. Siemens strongly recommends that product updates are applied as soon as they are available and that the latest product versions are used. Use of product versions that are no longer supported, and failure to apply the latest updates may increase customers' exposure to cyber threats.
  • Page 5 Important information Disclaimer for third-party software updates This product includes third-party software. Siemens AG only provides a warranty for updates/patches of the third-party software, if these have been distributed as part of a Siemens software update service contract or officially released by Siemens AG. Otherwise, updates/patches are undertaken at your own risk.
  • Page 6: Table Of Contents

    Level: "Exit" tab ........................24 Update firmware ............................25 Booting from USB stick ..........................26 Enable Trusted Platform Module (TPM) ....................27 Automatic switching on of the device ....................... 28 Index ................................ 29 Firmware/BIOS description SIMATIC IPC127E Operating Instructions, 01/2019, A5E45911216-AA...
  • Page 7: Using The Firmware Selection Menu

    The "Chose an Option" window opens. 4. Select the "Troubleshoot" option. 5. Select "UEFI / Firmware Settings". 6. Click "Restart". Result The "Main Page" with the options of the firmware selection menu (Page 8) is open. Firmware/BIOS description SIMATIC IPC127E Operating Instructions, 01/2019, A5E45911216-AA...
  • Page 8: Firmware Selection Menu Options

    Administer Secure Boot Configure device startup in "Secure Boot Modus". Setup Utility Start firmware configuration menu. BIOS Update Perform BIOS update. You can find more detailed information under "Update firmware (Page 25)". Firmware/BIOS description SIMATIC IPC127E Operating Instructions, 01/2019, A5E45911216-AA...
  • Page 9: Configure Firmware

    "Miscellaneous Configuration" (Page 15) Level: "Security" tab (Page 16) Advanced CPU Control (Page 18) Level: "Power" tab (Page 20) Level: "Boot" tab (Page 22) "EFI" (Page 23) Level: "Exit" tab (Page 24) Firmware/BIOS description SIMATIC IPC127E Operating Instructions, 01/2019, A5E45911216-AA...
  • Page 10: Keyboard Inputs In Setup Utility

    Navigate to a submenu or a firmware setting. Confirm your selection with the <Return> button. <Esc> A submenu or tab or the Setup Utility is exited. If the Setup Utility is closed after the confirmation prompt, changes to the firmware settings are discarded. Firmware/BIOS description SIMATIC IPC127E Operating Instructions, 01/2019, A5E45911216-AA...
  • Page 11: Main" Tab

    L2 cache size total. Total Memory Total memory size. BXT SOC SIC Version MRC Version Microcode Microcode version. PMC FW PUNIT FW TXE FW Version of the Graphics Output Protocol (GOP) driver. Firmware/BIOS description SIMATIC IPC127E Operating Instructions, 01/2019, A5E45911216-AA...
  • Page 12 Key functions for setting the numeric time and date values Button Function <Return> Switch between the setting options within a firmware setting, e.g. from hour to minute. [+] [-] Increase or decrease desired value. [0] - [9] Enter desired value. Firmware/BIOS description SIMATIC IPC127E Operating Instructions, 01/2019, A5E45911216-AA...
  • Page 13: Advanced" Tab

    3, X3 P1) Enabled The onboard Ethernet interface "X3 P1" is enabled. Onboard Ethernet 20:87:56:70:48:73 The Onboard Ethernet 3 address is defined with this value. 3 Address: *The Ethernet addresses are merely an example. Firmware/BIOS description SIMATIC IPC127E Operating Instructions, 01/2019, A5E45911216-AA...
  • Page 14: Sata Configuration

    The USB Configuration works in xHCI mode. USB devices are recognized during booting and used in the operating system. USB Per-Port Control Disabled The USB ports (0-3) are disabled. Enabled The USB ports (0-3) are enabled. Firmware/BIOS description SIMATIC IPC127E Operating Instructions, 01/2019, A5E45911216-AA...
  • Page 15: Miscellaneous Configuration

    Select: "Setup Utility (Page 9)" > "Advanced" > "Miscellaneous Configuration". Firmware setting Value Setting in Meaning delivery state IPC127E High Precision Timer Disabled The High Precision Event Timer is disabled. Enabled The High Precision Event Timer is enabled. Firmware/BIOS description SIMATIC IPC127E Operating Instructions, 01/2019, A5E45911216-AA...
  • Page 16: Security" Tab

    (only if a "Supervi- sor Password" was set up) Here you enter the previously defined "Supervisor Password" Enter New Pass- • once again. word Again: (only if a "Supervi- sor Password" was set up) Firmware/BIOS description SIMATIC IPC127E Operating Instructions, 01/2019, A5E45911216-AA...
  • Page 17 After correct entry of the user password, it can be changed by entering a new one. If no password is entered and only the <Re- turn> key is pressed, the configured user password is deleted. Firmware/BIOS description SIMATIC IPC127E Operating Instructions, 01/2019, A5E45911216-AA...
  • Page 18: Power" Tab

    Example: The settings C7, C6, C1 are available. Firmware/BIOS description SIMATIC IPC127E Operating Instructions, 01/2019, A5E45911216-AA...
  • Page 19 To use the Turbo mode effectively, the performance modes of the processor "PStates (IST)" and energy saving modes of the pro- cessor "C States" must be enabled. Disabled Turbo mode is disabled. Firmware/BIOS description SIMATIC IPC127E Operating Instructions, 01/2019, A5E45911216-AA...
  • Page 20: Level: "Power" Tab

    By OS With "By OS Utility" you specify when the OS can switch on the • Utility device in the S5 operating state. (only if "Auto Wake on S5" = "By OS Utility") Firmware/BIOS description SIMATIC IPC127E Operating Instructions, 01/2019, A5E45911216-AA...
  • Page 21 Enabled The LAN controller of the onboard Ethernet interface "X3 P1" can switch on the device. Requirement: The firmware setting "Wake on PME" must be set to "Enabled". Firmware/BIOS description SIMATIC IPC127E Operating Instructions, 01/2019, A5E45911216-AA...
  • Page 22: Boot" Tab

    Newly detected boot media are placed automatically in the boot order, e.g. dependent on the device path for UEFI boot media. Last Newly detected boot media are placed at the bottom of the boot order. Firmware/BIOS description SIMATIC IPC127E Operating Instructions, 01/2019, A5E45911216-AA...
  • Page 23: Efi

    ● If "Add Boot Options" = "First" or "Last", the following can be changed: – Sequence of the boot media: <F6>, <F5> or <+>, <-> keys – List of valid boot media: <Return> button Firmware/BIOS description SIMATIC IPC127E Operating Instructions, 01/2019, A5E45911216-AA...
  • Page 24: Exit" Tab

    All changes to the firmware settings are discarded. Save setup settings to file The current firmware settings are written to a file. Load setup settings from file Firmware settings are loaded from a file. Firmware/BIOS description SIMATIC IPC127E Operating Instructions, 01/2019, A5E45911216-AA...
  • Page 25: Update Firmware

    You can find information on this under "Level: "Exit" tab (Page 24)". Procedure 1. Open the "SIEMENS Industry Online Support (https://support.industry.siemens.com/cs/ww/en/view/75842768)" page. 2. Navigate to your device in the area "Online Support; Drivers and BIOS Updates for download".
  • Page 26: Booting From Usb Stick

    USB stick. 1. Connect the USB stick to the device. 2. Open the firmware selection menu (Page 7). 3. Select "Boot-Manager." 4. Select the USB medium in the "Boot-Manager" and confirm the entry. Firmware/BIOS description SIMATIC IPC127E Operating Instructions, 01/2019, A5E45911216-AA...
  • Page 27: Enable Trusted Platform Module (Tpm)

    3. Ensure that the "Available" value is assigned to firmware setting "TPM Availability". 4. Save the changes you made before closing the Setup Utility. You can find information on this under "AUTOHOTSPOT". Firmware/BIOS description SIMATIC IPC127E Operating Instructions, 01/2019, A5E45911216-AA...
  • Page 28: Automatic Switching On Of The Device

    During system planning, check whether this automatic startup of your machine or system poses a safety risk and then change the device behavior appropriately. See also Level: "Exit" tab (Page 24) Firmware/BIOS description SIMATIC IPC127E Operating Instructions, 01/2019, A5E45911216-AA...
  • Page 29: Index

    Boot order, 22 Firmware selection menu Boot procedure open manually, 7 Configuring, 13 Opening, 7 BXT SOC, 11 Firmware selection menu By Sleep Time, 20 Options, 8 Firmware version, 11, (Article number) Firmware/BIOS description SIMATIC IPC127E Operating Instructions, 01/2019, A5E45911216-AA...
  • Page 30 Onboard Ethernet 3 (LAN 3, X3 P1), 13 Onboard Ethernet 3 Address, 13 UEFI Network Stack, 22 USB Boot, 23 Password Management, 17 USB Configuration, 14 Password Management Interface, 17 USB Per-Port Control, 14 Firmware/BIOS description SIMATIC IPC127E Operating Instructions, 01/2019, A5E45911216-AA...
  • Page 31 Wake on LAN 2 (X2 P1), 21 Wake on LAN 3 (X3 P1), 21 Wake on PME, 20 Wake on RTC from S5, 20 Wake on S5 Time, 20 xHCI Mode, 14 Firmware/BIOS description SIMATIC IPC127E Operating Instructions, 01/2019, A5E45911216-AA...
  • Page 32 Index Firmware/BIOS description SIMATIC IPC127E Operating Instructions, 01/2019, A5E45911216-AA...

Table of Contents