Page 1
SIMATIC IPC1047E Preface Overview SIMATIC Safety Instructions Installing and connecting the device Industrial PC SIMATIC IPC1047E Commissioning the device Operating the device Operating Instructions Expanding and assigning parameters to the device Device maintenance and repair Technical specifications Dimension drawings Standards and approvals...
Page 2
Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
A solid background in electrical installation, personal computers, Microsoft operating systems and network technology is required to understand this manual. Validity of the Operating Instructions These operating instructions are valid for all supplied versions of the SIMATIC IPC1047E. Scope of this documentation The documentation for the SIMATIC IPC1047E includes: •...
Page 4
Preface History Currently released versions of these operating instructions: Version Comments 08/2020 First edition 03/2021 Redesign on the device, security information, hardware section added SIMATIC IPC1047E Operating Instructions, 03/2021, A5E50259546-AA...
Connecting the power supply ..................... 38 3.3.2.1 Information about the power supply .................. 38 3.3.2.2 Connecting a single power supply ..................39 3.3.2.3 Connecting a redundant power supply ................39 3.3.3 Connecting I/O devices ...................... 40 SIMATIC IPC1047E Operating Instructions, 03/2021, A5E50259546-AA...
Page 6
Removing and installing 3.5" drives from/in tray ..............74 6.5.3.4 Removing and installing 2.5" drives from/in tray ..............74 6.5.4 Replacing a defective hard disk drive in the RAID system ............. 77 6.5.5 Install M.2 NVMe SSD ......................78 SIMATIC IPC1047E Operating Instructions, 03/2021, A5E50259546-AA...
Page 7
Service and support ......................115 Troubleshooting ......................116 A.2.1 Problems with device functions ..................116 A.2.2 Problems with the RAID system and device startup ............118 A.2.3 Problems when using expansion cards ................119 SIMATIC IPC1047E Operating Instructions, 03/2021, A5E50259546-AA...
Page 8
Table of contents Markings and symbols ........................121 Overview ......................... 121 Safety ..........................121 Operator controls ......................121 Certificates, approvals and markings ................122 Interfaces ........................123 Abbreviations ............................ 125 Glossary ............................. 131 Index ..............................139 SIMATIC IPC1047E Operating Instructions, 03/2021, A5E50259546-AA...
Changes compared with these SIMATIC IPC Documentation operating instructions (http://www.siemens.com/simatic -ipc-doku-portal) Firmware/BIOs descrip- Information on: • Supplied data storage medium tion • Important firmware settings • Firmware settings in the factory state • Boot modes SIMATIC IPC1047E Operating Instructions, 03/2021, A5E50259546-AA...
(http://w3.siemens.com/mcms/au tomation/en/industrial- communica- tions/Pages/Default.aspx) 1.1.2 Overview The SIMATIC IPC1047E is a high-performance rack PC with industrial functionality: • Highly compact • Extremely rugged • Extensive product continuity Note Depending on the configuration ordered, the features and illustrations described in this manual may differ from the features of your device.
• Very fast M.2 SSDs • Hardware RAID – Auto-Rebuild for change of hard disk – Reduced load on the main processor during the rebuild – Fast HDDs/SSDs for high speed when reading and writing data SIMATIC IPC1047E Operating Instructions, 03/2021, A5E50259546-AA...
② Reset button ③ On/off button ④ Captive locking screw of the enclosure cover ⑤ Slots for removable drives in drive cage type A ⑥ Slot covers for drives in drive cage type B SIMATIC IPC1047E Operating Instructions, 03/2021, A5E50259546-AA...
On/Off switch ⑥ Expansion card slots Rear view with redundant AC power supply ① Power connection socket ④ Handle ② Acknowledgment button with status LED ⑤ Interfaces ③ Power supply module ⑥ Expansion card slots SIMATIC IPC1047E Operating Instructions, 03/2021, A5E50259546-AA...
Maximum cable length -= 3 m; depending on the attenuation of the cable and the maximum data rate of the connection. Use the original connection technology of the I/O devices to be connected without adapters and with- out extensions. SIMATIC IPC1047E Operating Instructions, 03/2021, A5E50259546-AA...
PC in operation Access to hard disk No access GREEN Access FAN FAIL Fan status No error RED flashing Possible causes: • CPU heat sink fan fault • Front fan faulty • Power supply fan fault SIMATIC IPC1047E Operating Instructions, 03/2021, A5E50259546-AA...
The following figure shows an example with power supply module ① in operation and power supply module ② out of service. SIMATIC IPC1047E Operating Instructions, 03/2021, A5E50259546-AA...
• Power supply not connected • No drive installed • Device is switched on and a drive is installed Activity Status of the Flashes • Drive is active drive • Drive is not active SIMATIC IPC1047E Operating Instructions, 03/2021, A5E50259546-AA...
Overview 1.3 Accessories and spare parts Accessories and spare parts Accessories from Siemens are available for your device. These are not included in the scope of delivery. Obtaining accessories from the SIEMENS Industry Mall You can find additional information in the online ordering system Industry Mall (https://mall.industry.siemens.com).
• For control cabinet installation: Use a central, easily accessible AC circuit breaker close to the device, if possible. SIMATIC IPC1047E Operating Instructions, 03/2021, A5E50259546-AA...
Page 22
The device is tested and certified on the basis of the technical standards. In rare cases, functional restrictions can occur during plant operation. Validate the correct functioning of the plant to avoid functional restrictions. SIMATIC IPC1047E Operating Instructions, 03/2021, A5E50259546-AA...
Siemens’ products and solutions undergo continuous development to make them more secure. Siemens strongly recommends that product updates are applied as soon as they are available and that the latest product versions are used. Use of product versions that are no longer supported, and failure to apply latest updates may increase customer’s exposure to...
Page 24
2.2 Security information Disclaimer for third-party software updates This product includes third-party software. Siemens AG only provides a warranty for updates/patches of the third-party software, if these have been distributed as part of a Siemens software update service contract or officially released by Siemens AG. Otherwise, updates/patches are undertaken at your own risk.
Page 25
• Disable the response of the Windows operating system to plugging in a USB device. • Keep the BIOS firmware up to date. You can obtain more detailed information about the BIOS setup from the manufacturer in the manual on the motherboard (Page 108). SIMATIC IPC1047E Operating Instructions, 03/2021, A5E50259546-AA...
Page 26
Recommended security settings for IPCs (https://support.industry.siemens.com/cs/ww/en/view/109475014) Siemens observes the data protection guidelines, especially the requirements regarding data minimization (privacy by design). This means the following for this SIMATIC product: The product does not process / save any personal information, but only technical functional data (e.g.
Touching these areas or components can cause death or serious physical injury. • Always disconnect the cabinet from the mains before opening it. • Ensure that the power to the control cabinet cannot be turned on accidentally. SIMATIC IPC1047E Operating Instructions, 03/2021, A5E50259546-AA...
Page 28
Fire hazard due to overheating of the device Expansion cards generate additional heat. The device can overheat or cause a fire. • Observe the safety and installation instructions for the expansion cards. • Observe the max. permissible power consumption values. SIMATIC IPC1047E Operating Instructions, 03/2021, A5E50259546-AA...
Page 29
• UL approval of the device only applies when the UL-approved components are used according to their "Conditions of Acceptability". • We are not liable for functional limitations caused by the use of third-party devices or components. SIMATIC IPC1047E Operating Instructions, 03/2021, A5E50259546-AA...
• You can install the device without an additional fire protection enclosure. It meets the requirements for fire protection enclosures in accordance with IEC/EN/UL 61010-2-201. • Ensure that the installation opening for the device is splash-proof in areas which may be subject to splash water. SIMATIC IPC1047E Operating Instructions, 03/2021, A5E50259546-AA...
Page 31
A damaged device has unpredictable properties and states. Death or serious injury could occur. • Avoid installing and commissioning a damaged device. • Label the damaged device and keep it locked away. Send off the device for immediate repair. SIMATIC IPC1047E Operating Instructions, 03/2021, A5E50259546-AA...
Page 32
• Bring the device to room temperature before starting it up. • Do not expose the device to direct heat radiation from a heating device. • If condensation develops, wait approximately 12 hours or until the device is completely dry before switching it on. SIMATIC IPC1047E Operating Instructions, 03/2021, A5E50259546-AA...
5. Please keep the documentation in a safe place. It is required for initial commissioning and is part of the device. 6. Make a note of the identification data of the device (Page 34). SIMATIC IPC1047E Operating Instructions, 03/2021, A5E50259546-AA...
• Article number (1P) of the device • Microsoft Windows "Product Key" from the "Certificate of Authenticity" (COA label). You will need the Product Key if you reinstall the operating system. The following figure shows an example. SIMATIC IPC1047E Operating Instructions, 03/2021, A5E50259546-AA...
Touching these areas or components can cause death or serious physical injury. • Always disconnect the cabinet from the mains before opening it. • Ensure that the power to the control cabinet cannot be turned on accidentally. SIMATIC IPC1047E Operating Instructions, 03/2021, A5E50259546-AA...
• Mounting on telescopic rails The device can be installed horizontally in control cabinets and 19" rack systems. When telescopic rails are used for mounting, the device can be withdrawn fully from the cabinet or rack. SIMATIC IPC1047E Operating Instructions, 03/2021, A5E50259546-AA...
This device may only be connected to a grounded groundedSchuko socket outlet. Ensure that the power cords used are rated for the maximum current input and ambient temperature of the device and meet the requirements of the following standards: • ANSI/UL 817 • CSA C22.2 No. 21 SIMATIC IPC1047E Operating Instructions, 03/2021, A5E50259546-AA...
• For control cabinet installation: Use a central, easily accessible AC circuit breaker close to the device, if possible. SIMATIC IPC1047E Operating Instructions, 03/2021, A5E50259546-AA...
• You have observed the Information about the power supply (Page 38). • The connecting cables, connectors, sockets and connection materials used meet the requirements according to section "Country-specific information on supply voltage (Page 37)". SIMATIC IPC1047E Operating Instructions, 03/2021, A5E50259546-AA...
1. Connect the I/O devices to the respective interfaces. Information on the position of the interfaces is available in "Interfaces at rear of the device (Page 16)". 2. Secure the cables with strain relief, if necessary. SIMATIC IPC1047E Operating Instructions, 03/2021, A5E50259546-AA...
• An operating system is installed. The device can be supplied without an operating system. You can find additional information on installation of the operating system in the section "Installing the software (Page 93)". SIMATIC IPC1047E Operating Instructions, 03/2021, A5E50259546-AA...
The product key is located on the "Certificate of Authenticity" in the "Product Key" line, see section "Identification data of the device (Page 34)". Result The interface of the operating system is displayed every time you turn on the device and after the startup routine. SIMATIC IPC1047E Operating Instructions, 03/2021, A5E50259546-AA...
For non-Windows operating systems: • Briefly press the on/off button. The operating system is shut down. The "POWER" LED goes out. The device is switched off but not fully disconnected from the line voltage. SIMATIC IPC1047E Operating Instructions, 03/2021, A5E50259546-AA...
Page 44
Perform a hardware reset only in the case of an emergency. 1. Press the on/off switch for more than 4 seconds. 2. Alternatively, press the reset button. Information on the position of the buttons is available in the section "Front panel (Page 14)". SIMATIC IPC1047E Operating Instructions, 03/2021, A5E50259546-AA...
• 2.5" drives: Maximum 8 (with maximum overall height of 15 mm) • 3.5" drives: Maximum 4 Hard disks can be connected via SATA or corresponding drives via an additional Raid controller. SIMATIC IPC1047E Operating Instructions, 03/2021, A5E50259546-AA...
• Disable keyboard operation during the BIOS self test (POST) in the BIOS setup. You can obtain more detailed information about the BIOS setup from the manufacturer in the manual on the motherboard (Page 108). SIMATIC IPC1047E Operating Instructions, 03/2021, A5E50259546-AA...
The data backup takes place on SATA SSDs or HDDs. As a result, the system is able to continue operation in the event of a defective hard disk or port connection problems, thereby achieving high availability. An optionally available hot-spare drive can further increase the availability of the system. SIMATIC IPC1047E Operating Instructions, 03/2021, A5E50259546-AA...
Page 48
5.2 Drive configurations ① Connection for the SATA data cable ② Connection for Zero Maintenance Module (ZMM) The installed RAID controller for the "Adaptec RAID 3151" module is displayed as follows in the BIOS: SIMATIC IPC1047E Operating Instructions, 03/2021, A5E50259546-AA...
This software offers additional functions, such as signaling the status of the RAID system. Additional information is available in the sections "RAID systems (Page 46)" and "Installing and configuring the hardware RAID adapter card (Page 60)". SIMATIC IPC1047E Operating Instructions, 03/2021, A5E50259546-AA...
• Power management with remote switch-on and switch-off of system • System access at BIOS level • Integration of virtual media, e.g. installation medium • Event display with logging • KVM console (KVM-Over-IP for Video Redirection) See also IPMI Setup (Page 102) SIMATIC IPC1047E Operating Instructions, 03/2021, A5E50259546-AA...
The warranty does not cover a reset of the hardware in the event of a loss of a password. Please store the password carefully and make sure it is protected against unauthorized access. SIMATIC IPC1047E Operating Instructions, 03/2021, A5E50259546-AA...
• The device is fully disconnected from the line voltage, see section "Switching off the device (Page 43)". • All connecting cables are unplugged • The front door is open; see section "Opening the front door (Page 45)". • Tx10 screwdriver SIMATIC IPC1047E Operating Instructions, 03/2021, A5E50259546-AA...
Page 54
4 slotted holes to the end of the slotted holes. 4. Remove the cover upwards vertically and evenly without tilting it. To close the device, proceed in the reverse order. SIMATIC IPC1047E Operating Instructions, 03/2021, A5E50259546-AA...
Internal construction of the device ① Power supply, single or redundant ② Slots for memory modules ③ Air baffle plate ④ Drive cage ⑤ ⑥ Processor heat sink ⑦ M.2 NVMe SSD ⑧ Motherboard ⑨ Expansion card slots SIMATIC IPC1047E Operating Instructions, 03/2021, A5E50259546-AA...
• If the NVIDIA Quadro RTX5000 graphics card is installed, e.g. ex works, no additional expansion cards may be installed (see section "Configuration variants (Page 57)", Maximum configuration). SIMATIC IPC1047E Operating Instructions, 03/2021, A5E50259546-AA...
In the factory settings, the NVIDIA Quadro RTX5000 graphics card is already installed with a power loss of 260 W. Please note the following: • You may then not install any additional expansion cards. • You can only combine one HW RAID controller with it. SIMATIC IPC1047E Operating Instructions, 03/2021, A5E50259546-AA...
There is a risk of injury at the rotating parts of the fan, e.g. through cutting. • Wait until the fan blades come to a standstill. • Only then should you remove the graphics card. SIMATIC IPC1047E Operating Instructions, 03/2021, A5E50259546-AA...
Page 59
⑥ and place it carefully on the mount- ing base. The modules face down. 5. Loosen the screws ⑤ on the graphics card ④. 6. Remove the support adapter ⑥ forwards. SIMATIC IPC1047E Operating Instructions, 03/2021, A5E50259546-AA...
– SATA data cable ① – Capacitor block of the ZMM ② (delivery stage 2) • An adapter cable for connection of the hard disk drive ① to the RAID module Observe the numbering of the connections ②. SIMATIC IPC1047E Operating Instructions, 03/2021, A5E50259546-AA...
Page 61
• "Drives Write Cache = Disabled", which means the write cache of the hard disk is switched off. • "Alarm Control = Disabled", which means the acoustic alarm in case of a fault is switched off SIMATIC IPC1047E Operating Instructions, 03/2021, A5E50259546-AA...
– Combination and exact equipping of the memory modules – Instructions and conditions for use • The device is open; see section "Open the device. (Page 53)". • Observe the "Repair information (Page 79)", in particular for electrostatic sensitive devices (ESD). SIMATIC IPC1047E Operating Instructions, 03/2021, A5E50259546-AA...
Page 63
5. Close the device. Display of a changed memory configuration A new memory configuration is detected automatically. The allocation of the "base memory and extended memory" is automatically displayed when you switch on the device. SIMATIC IPC1047E Operating Instructions, 03/2021, A5E50259546-AA...
• Permissible operating temperature range: 0 ... 50 °C Mounting options (view from above) ① Drive in drive bay for internal, robust installation ② Drive type "SATA" is possible. With maximum overall height of 15 mm SIMATIC IPC1047E Operating Instructions, 03/2021, A5E50259546-AA...
• If there is no RAID system: The device is fully disconnected from the line voltage, see section "Switching off the device (Page 43)". • The device you wish to replace is inactive. • When replacing an HD: T10 screwdriver • When replacing an SSD: T8 screwdriver SIMATIC IPC1047E Operating Instructions, 03/2021, A5E50259546-AA...
Page 66
Ensure that the removable tray fits tightly in the drive cage. 10. Close the tray bracket. 11. Lock the removable tray with the key. Note The removable tray must always be locked to ensure reliable operation of the devices with removable trays. SIMATIC IPC1047E Operating Instructions, 03/2021, A5E50259546-AA...
① and push the drive mounting bar forward from the device in the direction of the arrow. 2. Remove the blanking plate. 3. Push the 5.25" adapter for the removable racks from the front into the drive cage. SIMATIC IPC1047E Operating Instructions, 03/2021, A5E50259546-AA...
• The device is open; see section "Open the device. (Page 53)". Procedure 1. Press the locks ① of the cover ② together inside the device and keep them pressed. 2. Push the locks to the front in the direction of the arrow. SIMATIC IPC1047E Operating Instructions, 03/2021, A5E50259546-AA...
Page 69
7. Insert the cover ② into the front of the device. 8. At the backplane, connect the data cables with the corresponding interfaces on the motherboard or the hardware RAID controller. 9. Connect the power supply. 10. Close the device. SIMATIC IPC1047E Operating Instructions, 03/2021, A5E50259546-AA...
③. 3. Remove the unlatched backplane board ④ by turning it upwards from the brackets and removing it from the drive cage. See also Installing a backplane for removable tray (Page 68) SIMATIC IPC1047E Operating Instructions, 03/2021, A5E50259546-AA...
The figure below shows the rear view of the drive cage with open device. The bottom three trays in the drive cage are equipped as follows: Additional mounting location: An additional hard disk drive can be installed between the top mounting location and the enclosure wall. SIMATIC IPC1047E Operating Instructions, 03/2021, A5E50259546-AA...
3. Place the tray on the mounting base. Installation Proceed in the reverse order for the installation. Ensure that the tray latches in the bottom of the drive cage. SIMATIC IPC1047E Operating Instructions, 03/2021, A5E50259546-AA...
Removing and installing 2.5" drives from/in tray Requirement • The tray has been removed, see section "Removing and installing a tray from/in the drive cage (Page 73)". • 1 drive • 1 soft mounting base SIMATIC IPC1047E Operating Instructions, 03/2021, A5E50259546-AA...
Page 75
Ensure that each hole of the tray is positioned exactly over the threads of the drive. 4. Screw on the drive from behind. Do not tighten the screws too much. Do not exceed the maximum tightening torque of 0.7 Nm. SIMATIC IPC1047E Operating Instructions, 03/2021, A5E50259546-AA...
Page 76
Expanding and assigning parameters to the device 6.5 Drives Installation in vertical format Installation in horizontal format SIMATIC IPC1047E Operating Instructions, 03/2021, A5E50259546-AA...
3. Replace the defective hard disk with a hard disk of the same type and capacity. See also Drives in drive cage type A (Page 65) Drives in drive cage type B (Page 71) SIMATIC IPC1047E Operating Instructions, 03/2021, A5E50259546-AA...
• The device is open; see section "Open the device. (Page 53)". Procedure 1. Proceed as described by the manufacturer on the Internet: SUPERMICRO X11DPi-N User manual (https://www.supermicro.com/manuals/motherboard/C620/MNL-1773.pdf), section 2.7 "Connectors", under "PCIe M.2 Slot". SIMATIC IPC1047E Operating Instructions, 03/2021, A5E50259546-AA...
• UL approval of the device only applies when the UL-approved components are used according to their "Conditions of Acceptability". • We are not liable for functional limitations caused by the use of third-party devices or components. SIMATIC IPC1047E Operating Instructions, 03/2021, A5E50259546-AA...
You may only use filters of the same type. Information about the original spare parts for SIMATIC PCs is available in the Internet at SIMATIC IPC after-sales information system (http://www.siemens.com/asis). Filter pads are available as a pack of 10 under the article number A5E37019277. SIMATIC IPC1047E Operating Instructions, 03/2021, A5E50259546-AA...
• The device is fully disconnected from the line voltage, see section "Switching off the device (Page 43)". • The device is open; see section "Open the device. (Page 53)". • 1 fan, see information in section "Accessories and spare parts (Page 20)" SIMATIC IPC1047E Operating Instructions, 03/2021, A5E50259546-AA...
Page 82
1. Detach the plug of the connecting cable of the fan from the mother- board. 2. Detach the protective grille from the device fan. 3. Lift the device fan in the marked keyhole and remove it towards the front. SIMATIC IPC1047E Operating Instructions, 03/2021, A5E50259546-AA...
"Accessories and spare parts (Page 20)". Procedure 1. Detach the fan cable from the motherboard. 2. Press the upper and lower lock ① on the fan support and remove the fan support from the drive cage. SIMATIC IPC1047E Operating Instructions, 03/2021, A5E50259546-AA...
Page 84
7. Finally, snap the new fan completely into place in the locking latches ②. 8. Mount the fan support on the drive cage (see above). 9. Connect the fan cable to the motherboard. See also Maintenance intervals (Page 80) SIMATIC IPC1047E Operating Instructions, 03/2021, A5E50259546-AA...
The configuration data of the device may be deleted after battery replacement, depending on the BIOS setting. With BIOS setting "Profile: User", the configuration data of the device is retained; only the date and time must be set again. SIMATIC IPC1047E Operating Instructions, 03/2021, A5E50259546-AA...
Page 86
• Close the device as specified in section "Open the device. (Page 53)". • Set the BIOS setup. The configuration data of the device may be deleted after a battery replacement depending on the BIOS setup setting. SIMATIC IPC1047E Operating Instructions, 03/2021, A5E50259546-AA...
6. Slide the new power supply module into the frame all the way to the rear until it clicks into place. 7. Reconnect the power plug ②. Alternatively, restart the device. Both LEDs ① and ④ light in green again. SIMATIC IPC1047E Operating Instructions, 03/2021, A5E50259546-AA...
Information about original spare parts for SIMATIC IPCs is available on the Internet at: – Contacts (http://www.siemens.com/automation/partner) – SIMATIC IPC after-sales information system (http://www.siemens.com/asis) • Torx screwdriver T30, at least 120 mm in length • Observe the "Repair information (Page 79)", in particular for electrostatic sensitive devices "ESD directive".
Page 89
8. Remove the processor from the plastic base. Do not touch the processor and its connections in the process (see "ESD directive"). 9. Prepare the new processor by coating it with sufficient fresh thermo-lubricant. SIMATIC IPC1047E Operating Instructions, 03/2021, A5E50259546-AA...
Page 90
If the installed processor is operated with a higher clock frequency than permitted, it can be destroyed or cause loss of data. Operate the processor only at a clock frequency that is equal to or less than the permitted clock frequency. SIMATIC IPC1047E Operating Instructions, 03/2021, A5E50259546-AA...
– Memory modules (optional), see section "Removing memory modules (Page 62)" – M.2 NVMe SSD (optional), see section "Install M.2 NVMe SSD (Page 78)" 2. Note the assignment of all cables to the motherboard. 3. Then disconnect all cables from the motherboard. SIMATIC IPC1047E Operating Instructions, 03/2021, A5E50259546-AA...
Page 92
7. Tighten all ten mounting screws again. If necessary, adjust the position of the motherboard while the mounting screws are half tightened. 8. Reconnect the cables at the correct positions on the motherboard. SIMATIC IPC1047E Operating Instructions, 03/2021, A5E50259546-AA...
• Windows 10, pre-installed • Windows server, pre-installed You can find additional information on the pre-installed operating system on the Internet under: • Windows 10 or Windows Server on the supplied USB stick (https://support.industry.siemens.com/cs/ww/en/view/109749498) SIMATIC IPC1047E Operating Instructions, 03/2021, A5E50259546-AA...
The Restore function restores the volume partitions, the operating system with installed device drivers, and the SIEMENS software products. Before performing the Restore function, observe the information in section "Back-up authorization or license key (Page 94)". Setting Boot mode...
Page 95
Option: "Restore existing system partition only" Use this option if you are want to restore only the C: (System) and the boot functionality. The partition D: (Data) and all data stored there is retained. SIMATIC IPC1047E Operating Instructions, 03/2021, A5E50259546-AA...
7.4.5 Installing Windows (Recovery) The recovery function only installs the operating system on your device. In contrast to the restore function, no device drivers and no SIEMENS software products are installed by the recovery function. Note Specific information on using the Windows operating systems is available on the Internet: •...
Page 97
You can set up partitions during the installation process and integrate storage controllers that are unknown to the operating system. To do so, select "Custom (advanced)" when prompted for the installation type in the "Install Windows" installation program. SIMATIC IPC1047E Operating Instructions, 03/2021, A5E50259546-AA...
Page 98
Please read the information under "Information for systems with RAID or AHCI controller" at the end of this section. Drive options Display of additional functions that you can use to set up the data storage media, (advanced) see the following figure. SIMATIC IPC1047E Operating Instructions, 03/2021, A5E50259546-AA...
Page 99
Information on how the data medium is partitioned in its factory state is available in the tables below. 2. Select the partition on which you want to install the operating system. 3. Click "Next". Installation is started. The Windows operating system is installed on the data medium. SIMATIC IPC1047E Operating Instructions, 03/2021, A5E50259546-AA...
4. Select the respective driver on the USB stick. 7.4.6 Installing Hardware RAID controller software Note Observe the "General information on commissioning (Page 41)" in section "Commissioning the device". Additional information is available in section "Installing drivers and software (Page 96)". SIMATIC IPC1047E Operating Instructions, 03/2021, A5E50259546-AA...
Note Documentation You can find the BIOS description from the manufacturer at Supermicro (https://www.supermicro.com/en/products/motherboard/X11DPi-N) SIMATIC IPC1047E Operating Instructions, 03/2021, A5E50259546-AA...
• Do not dispose the device or its replacement and expansion components in household waste and not at public waste disposal points. • For environmentally compatible recycling and disposal of the device and its components, contact a certified disposal company for electronic waste or your Siemens contact (product return (https://support.industry.siemens.com/cs/ww/en/view/109479891)). Observe the following: •...
IPC plus the power requirements of the other devices supplied via this circuit. The tripping characteristic of the higher-level fuse must hereby take into consideration the starting currents of the IPC and those of the other devices. SIMATIC IPC1047E Operating Instructions, 03/2021, A5E50259546-AA...
Page 104
Also observe the installation options and temperature specifications in section "Overview (Page 64)". Storage/transport –20 °C … +60 °C Gradient ≤ 20°K/h, no condensation Relative humidity Tested in accordance with IEC 60068-2-78, IEC 60068-2-30 SIMATIC IPC1047E Operating Instructions, 03/2021, A5E50259546-AA...
Page 105
In accordance with ISO 9001 Motherboard You can obtain more detailed information from the manufacturer, see section "Motherboard (Page 108)". Drives Hard disks • 2.5", internal • 3.5", internal (optional) Solid State Drive • 2.5" SATA, internal SIMATIC IPC1047E Operating Instructions, 03/2021, A5E50259546-AA...
Page 106
5V / 2 × 900 mA / high current Ethernet • 2 × Ethernet interface (RJ45) • 1 × dedicated IPMI interface (RJ45), Remote Boot, 10/100/1000 Mbps, electrically isolated * Electrical isolation within the safety extra-low voltage circuit (SELV) SIMATIC IPC1047E Operating Instructions, 03/2021, A5E50259546-AA...
+5 V 25 A +/-5% +3.3 V 25 A +/-5% +5 V aux 3.5 A +/-5% The total current consumption of the +5 V and + 3.3 V voltage must not exceed 40 A. SIMATIC IPC1047E Operating Instructions, 03/2021, A5E50259546-AA...
Devices with sinusoidal output voltage in the normal and buffered mode are identified with the classification "VFI-SS-.." or "VI-SS-..". Motherboard You can find more detailed information from the manufacturer at " Supermicro (https://www.supermicro.com/en/products/motherboard/X11DPi-N)". Specifically, the manual for motherboard: X11DPi-N User manual (https://www.supermicro.com/manuals/motherboard/C620/MNL- 1773.pdf) SIMATIC IPC1047E Operating Instructions, 03/2021, A5E50259546-AA...
The material with which this person comes into contact is of particular significance. The figure shows the maximum electrostatic voltages with which a person is charged, depending on humidity and material. These values conform to the specifications of IEC 61000-4-2. SIMATIC IPC1047E Operating Instructions, 03/2021, A5E50259546-AA...
Page 110
This way, the discharge energy does not reach and damage the sensitive components. – Discharge your body electrostatically before you take a measurement at a module. Do so by touching grounded metallic parts. Always use grounded measuring instruments. SIMATIC IPC1047E Operating Instructions, 03/2021, A5E50259546-AA...
PCIe Example PCIe: Graphics card NVIDIA TESLA 106.68 mm / 4.2" 111.15 mm / 4.38" 110 mm 312 mm / 12.28" 265 mm Single Slot Dual Slot: The card requires two free expansion slots SIMATIC IPC1047E Operating Instructions, 03/2021, A5E50259546-AA...
SIMATIC IPC1047 certificates (https://support.industry.siemens.com/cs/ww/en/ps/25596/cert). ISO 9001 certificate The Siemens quality management system for our entire product creation process (development, production and sales) meets the requirements of ISO 9001. This has been certified by DQS (the German society for the certification of quality management systems).
Page 114
가정 외의 지역에서 사용하는 것을 목적으로 합니다. WEEE Directive The device is low-emission, recyclable and meets the requirements of the WEEE Directive 2012/19/EU on the disposal of waste electrical and electronic equipment. Siemens AG is registered with Stiftung EAR, WEEE-Reg. No. DE 23691322. SIMATIC IPC1047E...
Technical support Service and support Technical support for the products covered in the manual is available in the Internet at: • Technical support (https://support.industry.siemens.com/cs/ww/en/) • Support Request (https://support.industry.siemens.com/cs/ww/en/ps) • After Sales Information System SIMATIC IPC/PG (https://support.industry.siemens.com/cs/ww/en/view/109782922) • Service (https://support.industry.siemens.com/cs/ww/en/sc) • Contact persons and office locations (https://www.automation.siemens.com/aspa_app?lang=en)
BIOS Setup. 2. Set the time and date in the setup menu. Although the BIOS setting is The backup battery is dead. Replace the backup battery. correct, the time and date are still wrong. SIMATIC IPC1047E Operating Instructions, 03/2021, A5E50259546-AA...
Page 117
One module is not switched on • Switch on both modules spite redundant • Both modules are connected so • Connect modules to separate AC circuits power supply in case of power fail- the same AC circuit SIMATIC IPC1047E Operating Instructions, 03/2021, A5E50259546-AA...
Change address in the link to the Adaptec Storage ware cannot be started Manager software to "localhost". Requirement: The certificate is stored in the "Trusted Root Certi- fication Authorities" certificate store and is not expired. SIMATIC IPC1047E Operating Instructions, 03/2021, A5E50259546-AA...
PC. If the error no longer occurs, the third- • Signal frequencies or signal party expansion card was the cause of the fault. Replace this levels are not adhered to expansion card with a Siemens card or contact the card sup- • Different connector pin as- plier. signments If the PC still crashes, contact your technical support team.
Disconnect the power plug before opening Only with drive cage type A with removable drives Operator controls Symbol Meaning Symbol Meaning On/off switch , without electrical On/off switch, without electrical isola- isolation tion Only with single power supply SIMATIC IPC1047E Operating Instructions, 03/2021, A5E50259546-AA...
Marking of Federal Communications Commission for the USA EFUP (Environment Friendly Use Peri- Approved for Korea od) marking for China Test mark of the Underwriters Labora- Disposal information, observe the tories local regulations. Approval for India SIMATIC IPC1047E Operating Instructions, 03/2021, A5E50259546-AA...
Monitor output (VGA) Line Out LAN interface, not approved for con- Microphone input necting WAN or telephone Serial interface Universal audio jack USB port Headphone output USB 2.0 high-speed port USB 3.0 super-speed port SIMATIC IPC1047E Operating Instructions, 03/2021, A5E50259546-AA...
Dynamic Random Access Memory Direct Current DC current Data Carrier Detect Data carrier signal detection DDRAM Double Data Random Access Memory Memory chip with high-speed interface DHCP Dynamic Host Configuration Protocol Protocol for configuring IP networks SIMATIC IPC1047E Operating Instructions, 03/2021, A5E50259546-AA...
Page 126
Hibernate Once - Resume Many Hyper-Threading HTML Hyper Text Markup Language Script language for creating Internet pages. HTTP Hypertext Transfer Protocol Protocol for data transfer on the Internet Hardware Hardware Input/Output Data input/output on computers Intel Application Accelerator SIMATIC IPC1047E Operating Instructions, 03/2021, A5E50259546-AA...
Page 127
Object Linking and Embedding Coordination of various Microsoft documents, e.g. spread- sheet in text editor. OLE for Process Control Standardized interface for industrial processes PATA Parallel ATA Personal computer Peripheral Component Interconnect High-speed expansion bus SIMATIC IPC1047E Operating Instructions, 03/2021, A5E50259546-AA...
Page 128
Serial number of the device Software Total Cost of Ownership Thin-Film-Transistor Type of LCD flat-screen Tele Type Asynchronous data transfer Transmit Data Data transfer signal Trusted Execution Technology Hardware implementation Watchdog Time Watchdog monitoring time SIMATIC IPC1047E Operating Instructions, 03/2021, A5E50259546-AA...
Page 129
Wireless LAN LWireless local area network World Wide Web Extended Disable Capability Hardware implementation Extended Graphics Array Graphic standard, maximum resolution 1024x768 pixels. Zero Maintenance Cache Protection Module Maintenance-free cache unit for saving cache contents SIMATIC IPC1047E Operating Instructions, 03/2021, A5E50259546-AA...
Communauté Européene. The CE symbol confirms the conformity of the product with all applicable EC directives such as the EMC Directive. Chipset Located on the motherboard, connects the processor with the RAM, the graphics controller, the PCI bus, and the external interfaces. SIMATIC IPC1047E Operating Instructions, 03/2021, A5E50259546-AA...
Page 132
RAM modules with and without ECC. EMC directive EU directive for electromagnetic compatibility. Compliance is confirmed by the CE symbol and the EC certificate of conformity. SIMATIC IPC1047E Operating Instructions, 03/2021, A5E50259546-AA...
Page 133
"Hibernate once - resume many" is a method for fast booting from a single Hibernate file that only needs to be created once. HORM ensures restoration of a uniform, saved system state when booting. SIMATIC IPC1047E Operating Instructions, 03/2021, A5E50259546-AA...
Page 134
The devices connected to a LAN are called nodes. The purpose of networks is the mutual use of files, printers or other resources. SIMATIC IPC1047E Operating Instructions, 03/2021, A5E50259546-AA...
Page 135
Legacy USB support Support of USB devices, e.g. mouse, keyboard, on the USB ports without driver. License key The license key represents the electronic license stamp of a license. Siemens provides the license keys for protected software. Low-voltage directive EC Product Safety Directive relating to the safety of products which are operated on low voltage (50 V AC to 1000 V AC, 70 V DC to 1500 V DC) and not specified in other directives.
Page 136
Two power supplies are available in redundant operation: The second power supply ensures the power supply of the device in the event of a failure of the first. Reset Hardware reset: Reset/restart of the PC using a button/switch. SIMATIC IPC1047E Operating Instructions, 03/2021, A5E50259546-AA...
Page 137
This design makes SSDs more rugged, provides shorter access times, low energy consumption and rapid data transfer. Track-At-Once In track-at-once recording, a CD can be written to in bits in several sessions if the CD was not closed. SIMATIC IPC1047E Operating Instructions, 03/2021, A5E50259546-AA...
Page 138
Zero Maintenance Cache Protection Module is a functional unit of the SAS Raid controller that stores data in the cache of the controller in the case of a voltage failure. This functional unit is maintenance-free. SIMATIC IPC1047E Operating Instructions, 03/2021, A5E50259546-AA...
Page 142
Operating system, 96, 96 USB connection sockets on the rear of the device with SMS-W480 motherboard, 16 USB port, 12 VGA interface, 12 Weight, 103 Windows Microsoft Windows Product Key, 34 X-HDD system, (Multi-disk system) SIMATIC IPC1047E Operating Instructions, 03/2021, A5E50259546-AA...