hit counter script

Technical Specifications; General Technical Specifications - Siemens SIMATIC IPC127E Operating Instructions Manual

Hide thumbs Also See for SIMATIC IPC127E:
Table of Contents

Advertisement

Technical specifications

6.1

General technical specifications

General technical specifications
Article number
Weight without mounting brackets
Supply voltage
Transient voltage interruption
Current consumption
Noise emission
Degree of protection
Protection class
Degree of pollution
Quality assurance
Note
Note the following when you operate the device according to IEC/EN/UL 61010-2-201:
• The device may only be connected to a 24 V DC power supply that meets the
requirements of safe extra-low-voltage (SELV/PELV) according to
IEC/EN/UL 61010-2-201.
• In areas subject to UL / CSA 61010-2-201, the device must be supplied with NEC Class 2
according to UL / CSA 61010-2-201 or a limited-energy circuit according to
UL / CSA 61010-1 during operation outside an enclosure.
SIMATIC IPC127E
Operating Instructions, 01/2019, A5E44296915-AA
See order documents
Standard: Approx. 320 g
Extended: Approx. 400 g
24 V DC (19.2 to 28.8 V)
Up to 5 ms buffer time at full load
Max. 10 events per hour; recovery time at least 1 s
max. 1.8 A at 24 V
< 40 dB(A) according to DIN 45635-1
IP 40 in accordance with IEC 60529
Protection class I in accordance with IEC 61140
Device is designed for environments with pollution degree 2
In accordance with ISO 9001
6
53

Advertisement

Table of Contents
loading

Table of Contents