Summary of Contents for Siemens SIMATIC ET 200SP HA
Page 1
Security information Preface Product overview SIMATIC Wiring ET 200SP HA Digital Input Module DI 8x230VAC Parameters HA (6DL1131-6GF00-0PK0) Displays and interrupts Manual Technical specifications Drivers, parameters, diagnostics messages and address space 12/2017 A5E39401560-AB...
Page 2
Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
Table of contents Security information............................5 Preface.................................7 Product overview............................9 Properties of the I/O module DI 8x230VAC HA...............9 Wiring.................................11 Pin assignment of the I/O module DI 8x230VAC HA.............11 Schematic circuit diagram......................13 Parameters..............................15 Parameters of the I/O module DI 8x230VAC HA..............15 Module/channel parameters....................15 Explanation of the module/channel parameters..............15 Displays and interrupts..........................17 Status and error displays of the I/O module DI 8x230VAC HA..........17...
Page 4
Table of contents Digital Input Module DI 8x230VAC HA (6DL1131-6GF00-0PK0) Manual, 12/2017, A5E39401560-AB...
Siemens’ products and solutions undergo continuous development to make them more secure. Siemens strongly recommends that product updates are applied as soon as they are available and that the latest product versions are used. Use of product versions that are no longer supported, and failure to apply the latest updates may increase customer’s exposure to cyber...
Page 6
Security information Digital Input Module DI 8x230VAC HA (6DL1131-6GF00-0PK0) Manual, 12/2017, A5E39401560-AB...
Preface [ID: 87228164363] Validity of the documentation This device manual describes the DI 8x230VAC HA I/O module with the article number 6DL1131-6GF00-0PK0. It complements the system manual of the ET 200SP HA Distributed I/O System. Functions that generally relate to the system are described in this manual. The information in this device manual and the system/function manuals enables you to put the ET 200SP HA into operation.
Page 8
Preface Digital Input Module DI 8x230VAC HA (6DL1131-6GF00-0PK0) Manual, 12/2017, A5E39401560-AB...
Product overview Properties of the I/O module DI 8x230VAC HA [ID: 80193251851] View of the module 8x 23 0V AC DI AG M T A. 0 B. 1 C. 2 D. 3 A. 4 B. 5 C. 6 D. 7 A.
Page 10
Product overview 3.1 Properties of the I/O module DI 8x230VAC HA The I/O module supports the following functions: ● Firmware update ● I&M identification data ● Parameter reassignment in RUN ● Value status QI You can configure the I/O module with HW Config and integrate it into your system. Accessories The following accessories must be ordered separately: ●...
Wiring Pin assignment of the I/O module DI 8x230VAC HA [ID: 80193296267] Terminal blocks You can operate the I/O module with the following terminal blocks: ● 6DL1193-6TP00-0DK0, light ● 6DL1193-6TP00-0BK0, dark The terminal block is not included in the scope of delivery of the I/O module and must be ordered separately.
Page 12
Wiring 4.1 Pin assignment of the I/O module DI 8x230VAC HA General pin assignment Table 4-1 Pin assignment of the DI 8x230VAC HA Terminal assignment Terminal assignment Explanations DI A.0 DI B.1 DI X.n: Input signal, channel n DI C.2 DI D.3 N X.n: Neutral conductor, channel n NC (Not Connected) The terminals are not connected to the DI...
Wiring 4.2 Schematic circuit diagram Schematic circuit diagram [ID: 80193442187] The following figure shows the block diagram of the DI 8x230VAC HA. ET 200SP HA Backplane bus interface Figure 4-1 Block diagram DI 8x230VAC HA Digital Input Module DI 8x230VAC HA (6DL1131-6GF00-0PK0) Manual, 12/2017, A5E39401560-AB...
Page 14
Wiring 4.2 Schematic circuit diagram Digital Input Module DI 8x230VAC HA (6DL1131-6GF00-0PK0) Manual, 12/2017, A5E39401560-AB...
Parameters Parameters of the I/O module DI 8x230VAC HA [ID: 80193473547] Configuring You configure the I/O module with PCS 7 V9.0 or higher. Parameters You define the functioning of the I/O module via parameters. See also Parameter assignment (Page 26) Module/channel parameters [ID: 91078990219] Parameters of the DI 8x230VAC HA...
Page 16
Parameters 5.3 Explanation of the module/channel parameters Potential group A potential group consists of a group of directly adjacent I/O modules within an ET 200SP station HA, which are supplied via a common supply voltage. A potential group begins with a light terminal block, via which the required supply voltage is fed to all I/O modules of the potential group.
Displays and interrupts Status and error displays of the I/O module DI 8x230VAC HA [ID: 80193846795] LED displays The following figure shows the LED displays (status and fault displays) of the I/O module. 8x230VAC DIAG MT 1P1 NC NC 1P2 2P1 NC NC 2P2 MAX.
Displays and interrupts 6.2 Interrupts DIAG LED Table 6-1 Diagnostics display of the DIAG LED DIAG LED Meaning The power supply of the ET 200SP HA is disrupted or switched off. Module is not configured. Flashing Module is configured, a diagnostics message is not pending. Module is configured, at least one diagnostic message is pending.
Page 19
Displays and interrupts 6.2 Interrupts ● Retentive memory in carrier module defective ● Retentive memory in the terminal block defective Maintenance messages The I/O module generates a maintenance message for the following events: ● Retentive memory in carrier module defective ●...
Page 20
Displays and interrupts 6.2 Interrupts Digital Input Module DI 8x230VAC HA (6DL1131-6GF00-0PK0) Manual, 12/2017, A5E39401560-AB...
Technical specifications [ID: 80193873419] Technical specifications of the DI 8x230VAC HA Article number 6DL1131-6GF00-0PK0 General information Product type designation DI 8x230VAC HA HW functional status FS01 Firmware version V1.0 ● FW update possible Usable terminal block TB type K0 Color code for module-specific color identifica‐ CC42 tion plate Product function...
Page 22
Technical specifications Article number 6DL1131-6GF00-0PK0 230 V ● Rated value (AC) ● for signal "0" 0V AC to 40V AC 74 V AC to 264 V AC ● for signal "1" Input current 10.8 mA ● for signal "1", typ. Input delay (for rated value of input voltage) for standard inputs 1.5 ms...
Page 23
Technical specifications Article number 6DL1131-6GF00-0PK0 -40 °C ● horizontal installation, min. ● horizontal installation, max. 70 °C -40 °C ● vertical installation, min. 60 °C ● vertical installation, max. Dimensions Width 22.5 mm Height 115 mm Depth 138 mm Weights Weight, approx.
Page 24
Technical specifications Digital Input Module DI 8x230VAC HA (6DL1131-6GF00-0PK0) Manual, 12/2017, A5E39401560-AB...
Drivers, parameters, diagnostics messages and address space Concept of the driver and diagnostics blocks [ID: 96680279307] Use outside the PCS 7 environment The following information of the appendix relates to the use of the ET 200SP HA outside the PCS 7 environment. If you do not plan to operate outside the PCS 7 environment, you do not need the information in the appendix.
A.2 Parameter assignment This block concept supports all modules from the list of approved modules. When new Siemens or non-Siemens module types are integrated, the meta-knowledge for the driver generator can be extended by additional XML files (object and action lists).
Drivers, parameters, diagnostics messages and address space A.3 Parameter assignment and structure of the module/channel parameters Output parameter STATUS If errors occur when transferring parameters with the "WRREC" instruction, the module continues operation with the previous parameter assignment. The STATUS output parameter contains the corresponding error code.
Page 28
Drivers, parameters, diagnostics messages and address space A.3 Parameter assignment and structure of the module/channel parameters Figure A-1 Structure of data record 128 Digital Input Module DI 8x230VAC HA (6DL1131-6GF00-0PK0) Manual, 12/2017, A5E39401560-AB...
Page 29
Drivers, parameters, diagnostics messages and address space A.3 Parameter assignment and structure of the module/channel parameters Header information and module parameters The following figure shows the structure of the header information and module parameters. Figure A-2 Header information and module parameters of data record 128 Channel parameters The following figure shows the configuration of the channel parameters for channels 0 to 7.
Drivers, parameters, diagnostics messages and address space A.4 Diagnostics messages and maintenance events Figure A-3 Configuration byte x to x+1 for the channels 0 to 7 Diagnostics messages and maintenance events [ID: 91089678859] Diagnostics messages A diagnostic message is generated for each diagnostic event and the DIAG LED on the DI 8x230VAC HA flashes red or the MT LED lights up yellow.
Drivers, parameters, diagnostics messages and address space A.5 Address space Maintenance messages do not have a direct influence on the functions of the module or digital inputs. Table A-2 Maintenance messages, their meaning and possible remedies Maintenance Error code Assignment Meaning / Cause Solution message...
Page 32
Drivers, parameters, diagnostics messages and address space A.5 Address space Digital Input Module DI 8x230VAC HA (6DL1131-6GF00-0PK0) Manual, 12/2017, A5E39401560-AB...