hit counter script
Siemens SCALANCE W788 Operating Instructions Manual

Siemens SCALANCE W788 Operating Instructions Manual

Industrial wireless lan

Advertisement

SIMATIC NET
Industrial Wireless LAN
SCALANCE W788-x / W748-1
Operating Instructions
09/2017
A5E03678333-12
___________________
Introduction
___________________
Security recommendations
___________________
Description of the device
___________________
Mounting
___________________
Connecting up
___________________
Upkeep and maintenance
___________________
Technical specifications
___________________
Dimension drawings
___________________
Certification
1
2
3
4
5
6
7
8
9

Advertisement

Table of Contents
loading

Summary of Contents for Siemens SCALANCE W788

  • Page 1 ___________________ Introduction ___________________ Security recommendations ___________________ SIMATIC NET Description of the device ___________________ Mounting Industrial Wireless LAN SCALANCE W788-x / W748-1 ___________________ Connecting up ___________________ Upkeep and maintenance Operating Instructions ___________________ Technical specifications ___________________ Dimension drawings ___________________ Certification 09/2017 A5E03678333-12...
  • Page 2 Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
  • Page 3: Table Of Contents

    Replacing the PLUG (C-PLUG or KEY-PLUG) ..............46 Upkeep and maintenance ........................49 Device configuration with PRESET-PLUG ................49 Restoring the factory settings ....................52 Firmware update via WBM or CLI not possible ..............54 SCALANCE W788-x / W748-1 Operating Instructions, 09/2017, A5E03678333-12...
  • Page 4 Table of contents Technical specifications ........................57 Technical specifications of the SCALANCE W7x8-1) ............57 Technical specifications of the SCALANCE W7x8-2) ............60 Dimension drawings ..........................63 Certification ............................65 Index ..............................67 SCALANCE W788-x / W748-1 Operating Instructions, 09/2017, A5E03678333-12...
  • Page 5: Introduction

    6GK5788-1GD00-0AA0 6GK5788-1GD00-0AB0 Dual access points SCALANCE W788-2 RJ-45 6GK5788-2FC00-0AA0 6GK5788-2FC00-0AB0 6GK5788-2FC00-0AC0 SCALANCE W788-2 M12 6GK5788-2GD00-0AA0 6GK5788-2GD00-0AB0 SCALANCE W788-2 M12 EEC 6GK5788-2GD00-0TA0 6GK5788-2GD00-0TB0 Ethernet client modules SCALANCE W748-1 RJ-45 6GK5748-1FC00-0AA0 6GK5748-1FC00-0AB0 SCALANCE W748-1 M12 6GK5748-1GD00-0AA0 6GK5748-1GD00-0AB0 If information relates to all the named products, the term SCALANCE W7x8 will be used.
  • Page 6 Siemens’ products and solutions undergo continuous development to make them more secure. Siemens strongly recommends that product updates are applied as soon as they are available and that the latest product versions are used. Use of product versions that are no longer supported, and failure to apply the latest updates may increase customer’s exposure...
  • Page 7: Security Recommendations

    ● Keep the software up to date. Check regularly for security updates of the product. You will find information on this on the Internet pages "Industrial Security (https://www.siemens.com/industrialsecurity)" ● Inform yourself regularly about security advisories and bulletins published by Siemens ProductCERT (https://www.siemens.com/cert/en/cert-security-advisories.htm). ● Only activate protocols that you really require to use the device.
  • Page 8 ● Verify certificates and fingerprints on the server and client to avoid "man in the middle" attacks. ● We recommend that you use certificates with a key length of 2048 bits. ● Change keys and certificates immediately, if there is a suspicion of compromise. SCALANCE W788-x / W748-1 Operating Instructions, 09/2017, A5E03678333-12...
  • Page 9 Port number assigned to the protocol ● Port status – Open The port is always open and cannot be closed. – Open (when configured) The port is open if it has been configured. SCALANCE W788-x / W748-1 Operating Instructions, 09/2017, A5E03678333-12...
  • Page 10 Syslog UDP/514 Open (when configured) Open EtherNet/IP TCP/44818, Open (when configured) Open UDP/2222,4 4818 DHCP UDP/67,68 Open (when configured) Closed RADIUS UDP/1812,1 Open (when configured) Closed TFTP UDP/69 Open (when configured) Closed SCALANCE W788-x / W748-1 Operating Instructions, 09/2017, A5E03678333-12...
  • Page 11: Description Of The Device

    Connector for the digital input/output (not with W788C) ⑦ PLUG compartment (not with W788C) ⑧ Reset button ⑨ Grounding connector (thread M4) on the back of the device Figure 3-1 Device description of the RJ-45 variant SCALANCE W788-x / W748-1 Operating Instructions, 09/2017, A5E03678333-12...
  • Page 12: Operating Instructions, 09/2017, A5E03678333

    ⑥ PLUG compartment (not with W788C) ⑦ Reset button (covered in the figure) ⑧ Grounding connector (thread M4) on the back of the device Figure 3-2 Device description of the M12 variant SCALANCE W788-x / W748-1 Operating Instructions, 09/2017, A5E03678333-12...
  • Page 13: Structure Of The Type Designations

    Description of the device 3.2 Structure of the type designations Structure of the type designations The type designation of a SCALANCE W7x8 is made up of several parts that have the following meaning: SCALANCE W788-x / W748-1 Operating Instructions, 09/2017, A5E03678333-12...
  • Page 14: Components Of The Product

    The mounting set with the holding plate does not ship with the device, see Accessories (Page 15). Please check that the consignment you have received is complete. If the consignment is incomplete, contact your supplier or your local Siemens office. SCALANCE W788-x / W748-1 Operating Instructions, 09/2017, A5E03678333-12...
  • Page 15: Accessories

    1 connector per 6GK1901-0DB30-6AA0 PLUG PRO Plug PRO 4x 2 M12 Plug-in connect- package or with rugged metal housing and FC 8 connectors per 6GK1901-0DB30-6AA8 connector technology, with axial package cable outlet (X coded) SCALANCE W788-x / W748-1 Operating Instructions, 09/2017, A5E03678333-12...
  • Page 16 4.5 mm, two N-Connect female Feedthrough connectors. N-Connect/SMA- Panel feedthrough for wall thicknesses up to a 6GK5798-0PT00-2AA6 Connect fe- maximum of 5.5 mm, two N-Connect/SMA female male/female Panel connectors. Feedthrough SCALANCE W788-x / W748-1 Operating Instructions, 09/2017, A5E03678333-12...
  • Page 17 LP798-2N Lighting protector with N/N female/female connector with 6GK5798-2LP10-2AA6 quarter wave technology Terminating resistor Component Description Article number TI795-1N Electrical connection 6GK5795-1TN00-1AA0 N-Connect, male TI795-1R Electrical connection 6GK5795-1TR10-0AA6 RSMA-Connect, male SCALANCE W788-x / W748-1 Operating Instructions, 09/2017, A5E03678333-12...
  • Page 18: Flexible Connecting Cables And Antennas

    Flexible connecting cable for connecting an antenna to a SCALANCE W700 with N-Connect connectors. Preassembled with two N male connectors: Length Article number 6XV1875-5AH10 6XV1875-5AH20 6XV1875-5AH50 10 m 6XV1875-5AN10 For railway applications, the following connecting cable are available: Length Article number 6XV1875-5SH10 6XV1875-5SH20 6XV1875-5SH50 SCALANCE W788-x / W748-1 Operating Instructions, 09/2017, A5E03678333-12...
  • Page 19: Antennas

    5 GHz, N-Connect female ANT793-8DJ Directional antenna, mast/wall mounting, 6GK5793-8DJ00-0AA0 18 dBi 5 GHz, 2 x N-Connect female ANT793-8DK Directional antenna, mast/wall mounting, 6GK5793-8DK00-0AA0 23 dBi 5 GHz, 2 x N-Connect female SCALANCE W788-x / W748-1 Operating Instructions, 09/2017, A5E03678333-12...
  • Page 20 Omni antenna, 0 dBi 2.400 - 2.485 GHz, 6XV1875-2A 2,4 GHz PE 1/2" N-Connect female. IWLAN RCoax Cable 5 Omni antenna, 0 dBi 5.150 – 5.875 GHz, 6XV1875-2D GHz PE 1/2" N-Connect female. SCALANCE W788-x / W748-1 Operating Instructions, 09/2017, A5E03678333-12...
  • Page 21 The antenna ANT793-8DK may only be used with the flexible connecting cable 6XV1875- 5CN10 (10 m length). Other flexible connecting cables are not permitted. Notice for USA/Canada Only one antenna per device can be used (connected to R1A1, R1A2 or R2A1, R2A2). SCALANCE W788-x / W748-1 Operating Instructions, 09/2017, A5E03678333-12...
  • Page 22: Led Display

    NOT WITH M12 VARIANTS Green Power supply using Power over Ethernet Green There is a connection via the Ethernet interface (Link). Green and yel- Data transfer via the Ethernet interface low flashing alternately SCALANCE W788-x / W748-1 Operating Instructions, 09/2017, A5E03678333-12...
  • Page 23 Afterwards the device is restarted and the device configuration incl. users interval: 2 sec. and certificates stored on the PRESET-PLUG is transferred to the device. on / 0.2 sec. off Flashing yellow "Flashing" enabled using SIMATIC NET Primary Setup Tool (PST). SCALANCE W788-x / W748-1 Operating Instructions, 09/2017, A5E03678333-12...
  • Page 24 If no primary user is detected, data traffic is possible again. The wait time of 30 minutes is necessary due to legal requirements and cannot be shortened even by restarting the device. SCALANCE W788-x / W748-1 Operating Instructions, 09/2017, A5E03678333-12...
  • Page 25: Reset Button

    If you reset, all the changes you have made will be overwritten by factory defaults. NOTICE Inadvertent reset An inadvertent reset can cause disturbances and failures in the configured network with further consequences. SCALANCE W788-x / W748-1 Operating Instructions, 09/2017, A5E03678333-12...
  • Page 26 Description of the device 3.6 Reset button SCALANCE W788-x / W748-1 Operating Instructions, 09/2017, A5E03678333-12...
  • Page 27: Mounting

    General notes on use according to ATEX and IECEx WARNING To comply with EC Directive 2014/34/EU (ATEX 114) or the conditions of IECEx, this enclosure or cabinet must meet the requirements of at least IP54 in compliance with EN 60529. SCALANCE W788-x / W748-1 Operating Instructions, 09/2017, A5E03678333-12...
  • Page 28: Securing The Housing

    - The minimum distance to fluorescent lamps should be 0.5 m. - When installed in a cabinet, we recommend that you do not install relays on the same or on directly neighboring mounting rails. SCALANCE W788-x / W748-1 Operating Instructions, 09/2017, A5E03678333-12...
  • Page 29: Wall Mounting

    Use the holes in the housing to screw the device to the wall or on a horizontal surface. The location of the holes can be seen in the following figure: Figure 4-1 Drilling pattern (dimensions in mm) ① Ground connector (thread M4) SCALANCE W788-x / W748-1 Operating Instructions, 09/2017, A5E03678333-12...
  • Page 30: Installing On The S7-300 Standard Rail

    1. Place the device on the upper edge of the S7-300 standard rail (position A). 2. Screw the device to the rail using the supplied screw (position B). Figure 4-2 Installing on an S7-300 standard rail SCALANCE W788-x / W748-1 Operating Instructions, 09/2017, A5E03678333-12...
  • Page 31: Installing On The S7-1500 Standard Rail

    1. Place the device on the upper edge of the S7-1500 standard rail (position A). 2. Screw the device to the rail using the supplied screw (position B). Figure 4-3 Installing on an S7-1500 standard rail SCALANCE W788-x / W748-1 Operating Instructions, 09/2017, A5E03678333-12...
  • Page 32: Installing On A Din Rail

    ● 1 DIN rail slider ● 1 spring ● 2 screws Mount the bracket on the rear of the device as shown in the figure below: Figure 4-4 Fitting the DIN rail slider SCALANCE W788-x / W748-1 Operating Instructions, 09/2017, A5E03678333-12...
  • Page 33 1. Place the device on the upper edge of the DIN rail (position A). 2. Pull the spring-mounted DIN rail slider (position B) down and press the device against the DIN rail until it locks in place. Figure 4-5 Installing on a DIN rail SCALANCE W788-x / W748-1 Operating Instructions, 09/2017, A5E03678333-12...
  • Page 34 Mounting 4.5 Installing on a DIN rail SCALANCE W788-x / W748-1 Operating Instructions, 09/2017, A5E03678333-12...
  • Page 35: Connecting Up

    Note Close unused sockets Close all unused M12 sockets with protective caps (torque at least 0.4 Nm) to achieve the specified type of protection. SCALANCE W788-x / W748-1 Operating Instructions, 09/2017, A5E03678333-12...
  • Page 36: Lightning Protection, Power Supply And Grounding

    The requirements of EN61000-4-5, surge immunity tests on power supply lines, are met only when a Blitzductor is used with 24 VDC: BVT AVD 24 article number: 918 422 Manufacturer: DEHN+SÖHNE GmbH+Co.KG, Hans Dehn Str. 1, Postfach 1640, D - 92306 Neumarkt, Germany SCALANCE W788-x / W748-1 Operating Instructions, 09/2017, A5E03678333-12...
  • Page 37 • Housing of the SCALANCE W700 and the ground potential of a device connected over Ethernet. • Housing of the SCALANCE W700 and the shield contact of the connected Ethernet cable. Connect both grounds to the same foundation earth or use an equipotential bonding cable. SCALANCE W788-x / W748-1 Operating Instructions, 09/2017, A5E03678333-12...
  • Page 38 This equipment is suitable for use in Class I, Division 2, Groups A, B, C and D or non- hazardous locations only. This equipment is suitable for use in Class I, Zone 2, Group IIC or non-hazardous locations only. SCALANCE W788-x / W748-1 Operating Instructions, 09/2017, A5E03678333-12...
  • Page 39: Power Supply And Ethernet

    Before you pull a plug via which the device is supplied with power using PoE, disable the relevant PoE power supply. Note No power sourcing equipment (PSE) The W7x8 cannot be used as a PoE power supply for other devices. SCALANCE W788-x / W748-1 Operating Instructions, 09/2017, A5E03678333-12...
  • Page 40 Refer to the information in the section Mounting (Page 27). Ethernet connector Depending on the model, the connection of the SCALANCE W7x8 to Ethernet is either via an RJ-45 interface or via an M12 interface. SCALANCE W788-x / W748-1 Operating Instructions, 09/2017, A5E03678333-12...
  • Page 41: Antenna Connectors

    ● Variants with an IWLAN interface (W7x8-1) have 3 antenna sockets on the top of the device. ● Variants with two IWLAN interfaces (W788-2) have 6 antenna sockets, 3 on the top and 3 on the underside of the device. SCALANCE W788-x / W748-1 Operating Instructions, 09/2017, A5E03678333-12...
  • Page 42 SCALANCE W778/W738 and a detached antenna are available from SIMATIC NET. You will find detailed information in the section Flexible connecting cables and antennas (Page 18). SCALANCE W788-x / W748-1 Operating Instructions, 09/2017, A5E03678333-12...
  • Page 43 You will find information on the configuration of the antennas in the following documents: • SCALANCE W7x8 SCALANCE W700 configuration manual, section "Configuring antennas" • SCALANCE W7x8C SCALANCE WLC711 User Guide, section "Configuring wireless AP radio properties" SCALANCE W788-x / W748-1 Operating Instructions, 09/2017, A5E03678333-12...
  • Page 44 Connecting up 5.4 Antenna connectors ① R1A1 ② R1A2 ③ R1A3 ④ R2A1 ⑤ R2A2 ⑥ R2A3 Figure 5-2 Antenna connector IP65 SCALANCE W788-x / W748-1 Operating Instructions, 09/2017, A5E03678333-12...
  • Page 45: Digital Input/Output

    The digital input/output is connected to a 4-pin plug-in terminal block with the following pin assignment: Signal Function DQ (output) Relay 24 VDC / 1 A 1L (output) Relay 24 VDC / 1 A DI (input plus) 24 VDC 1M (input ground) SCALANCE W788-x / W748-1 Operating Instructions, 09/2017, A5E03678333-12...
  • Page 46: Replacing The Plug (C-Plug Or Key-Plug)

    PLUG inserted, the SCALANCE W700 starts up with the configuration data on the PLUG. Position The PLUG slot is on the top of the device housing under a cover, see Device description (Page 11). SCALANCE W788-x / W748-1 Operating Instructions, 09/2017, A5E03678333-12...
  • Page 47 A C-PLUG only stores information about the configuration of a device. In addition to the configuration, a KEY-PLUG also contains a license with which you can enable special functions, for example iFeatures. You will find the article numbers in Accessories (Page 15). SCALANCE W788-x / W748-1 Operating Instructions, 09/2017, A5E03678333-12...
  • Page 48 Connecting up 5.6 Replacing the PLUG (C-PLUG or KEY-PLUG) SCALANCE W788-x / W748-1 Operating Instructions, 09/2017, A5E03678333-12...
  • Page 49: Upkeep And Maintenance

    IP addresses. You assign fixed IP addresses extra following the basic installation. Requirement ● A PLUG is inserted in the device on which you want to configure the PRESET-PLUG functionality. SCALANCE W788-x / W748-1 Operating Instructions, 09/2017, A5E03678333-12...
  • Page 50 If you have created the PRESET-PLUG from a KEY-PLUG, for operation with this configuration, you require an inserted KEY-PLUG. IN this case before recommissioning the device you need to insert the relevant KEY- PLUG. SCALANCE W788-x / W748-1 Operating Instructions, 09/2017, A5E03678333-12...
  • Page 51 3. You change to the PLUG configuration mode with the "plug" command. 4. Enter the command "factoryclean". The PRESET-PLUG is formatted and the preset function is reset. 5. Write the current configuration of the device with the "write" command. SCALANCE W788-x / W748-1 Operating Instructions, 09/2017, A5E03678333-12...
  • Page 52: Restoring The Factory Settings

    Follow the steps below to reset the device parameters to the factory defaults with the Primary Setup Tool. 1. Select the device whose parameters you want to reset. 2. Click on the menu item "Reset" in the "Module" tab. 3. Confirm the prompt with "OK". SCALANCE W788-x / W748-1 Operating Instructions, 09/2017, A5E03678333-12...
  • Page 53 You will find detailed information on resetting the device parameters using the WBM and CLI in the configuration manuals: ● Web Based Management, section "Restart" ● Command Line Interface, section "Reset and Defaults" SCALANCE W788-x / W748-1 Operating Instructions, 09/2017, A5E03678333-12...
  • Page 54: Firmware Update Via Wbm Or Cli Not Possible

    Note Use of CLI and TFTP in Windows 7 If you want to access the CLI or TFTP in Windows 7, make sure that the relevant functions are enabled in Windows 7. SCALANCE W788-x / W748-1 Operating Instructions, 09/2017, A5E03678333-12...
  • Page 55 Please note that the transfer of the firmware can take several minutes. During the transmission, the red error LED (F) flashes. Once the firmware has been transferred completely to the device, the device is restarted automatically. See also Reset button (Page 25) SCALANCE W788-x / W748-1 Operating Instructions, 09/2017, A5E03678333-12...
  • Page 56 Upkeep and maintenance 6.3 Firmware update via WBM or CLI not possible SCALANCE W788-x / W748-1 Operating Instructions, 09/2017, A5E03678333-12...
  • Page 57: Technical Specifications

    Technical specifications Technical specifications of the SCALANCE W7x8-1) The following technical specifications apply to the following devices: ● SCALANCE W788-1 RJ45 ● SCALANCE W788-1 M12 ● SCALANCE W748-1 RJ45 ● SCALANCE W748-1 M12 Note Bridging a power outage is possible only with an input voltage of 24 VDC (-15% to +20%).
  • Page 58 At 24 VDC / max. 15.6 W At 24 VDC / typical 10.7 W Digital input Quantity Design Terminal block, 2 terminals Status "0" 13 to 30 VDC Status "1" -30 to 3 VDC SCALANCE W788-x / W748-1 Operating Instructions, 09/2017, A5E03678333-12...
  • Page 59 The PoE class depends on the hardware version of the device. Devices with a hardware version ≥ 3 have PoE class 3. Devices with a lower hardware version have PoE class 4. SCALANCE W788-x / W748-1 Operating Instructions, 09/2017, A5E03678333-12...
  • Page 60: Technical Specifications Of The Scalance W7X8-2)

    The following technical specifications apply to the following devices: ● SCALANCE W788-2 RJ45 ● SCALANCE W788-2 M12 ● SCALANCE W788-2 M12 EEC Note Bridging a power outage is possible only with an input voltage of 24 VDC (-15% to +20%).
  • Page 61 At 24 VDC / typical 15 W Digital input Quantity Design Terminal block, 2 terminals Status "0" 13 ... 30 VDC Status "1" -30 to 3 VDC Max. input current 8 mA SCALANCE W788-x / W748-1 Operating Instructions, 09/2017, A5E03678333-12...
  • Page 62 With additional holding plate Mast mounting Mounting on a DIN rail Mounting on an S7-300 standard rail Mounting on an S7-1500 standard rail Mean time between failure (MTBF) At 40 °C ambient temperature 41 years SCALANCE W788-x / W748-1 Operating Instructions, 09/2017, A5E03678333-12...
  • Page 63: Dimension Drawings

    Dimension drawings The following dimensions are specified in mm. Dimension drawing of the SCALANCE W7x8-2 RJ45 (degree of protection IP30) Figure 8-1 Front view RJ-45 Figure 8-2 View from above RJ-45 SCALANCE W788-x / W748-1 Operating Instructions, 09/2017, A5E03678333-12...
  • Page 64 Dimension drawings Dimension drawing of the SCALANCE W7x8-2 M12 (degree of protection IP65) Figure 8-3 Front view M12 Figure 8-4 View from above M12 SCALANCE W788-x / W748-1 Operating Instructions, 09/2017, A5E03678333-12...
  • Page 65: Certification

    Certification You will find the approvals of the products in the reference work "Approvals SCALANCE W700 802.11n" on the Internet pages of Siemens Industry Online Support: ● Using the search function: support.automation.siemens.com (http://support.automation.siemens.com/WW/view/en) Enter the entry ID of the relevant manual as the search item.
  • Page 66 Certification SCALANCE W788-x / W748-1 Operating Instructions, 09/2017, A5E03678333-12...
  • Page 67: Index

    Technical specifications, 57, 57, 60, 60 Type designations, 13 Grounding, 36, 37 Installation DIN rail, 32 S7-300 standard rail, 30 Wall mounting, 29 Interfaces, 57, 60 LED display, 22 Lightning protection, 36 SCALANCE W788-x / W748-1 Operating Instructions, 09/2017, A5E03678333-12...
  • Page 68 Index SCALANCE W788-x / W748-1 Operating Instructions, 09/2017, A5E03678333-12...

This manual is also suitable for:

Scalance w748-1

Table of Contents