Simatic net industrial wireless lan to ieee 802.11n web based management (317 pages)
Summary of Contents for Siemens SCALANCE W774-1
Page 1
___________________ Introduction Security recommendations ___________________ SIMATIC NET Description of the device ___________________ Mounting Industrial Wireless LAN SCALANCE W774-1 /W734-1 ___________________ Connection Upkeep and maintenance Operating Instructions ___________________ Technical data ___________________ Dimension drawings ___________________ Approvals 01/2017 C79000-G8976-C325-08...
Page 2
Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
In order to protect plants, systems, machines and networks against cyber threats, it is necessary to implement – and continuously maintain – a holistic, state-of-the-art industrial security concept. Siemens’ products and solutions only form one element of such a concept. SCALANCE W774-1 /W734-1...
Page 6
Siemens’ products and solutions undergo continuous development to make them more secure. Siemens strongly recommends to apply product updates as soon as available and to always use the latest product versions. Use of product versions that are no longer supported, and failure to apply latest updates may increase customer’s exposure to cyber threats.
● Keep the software up to date. Check regularly for security updates of the product. You will find information on this on the Internet pages "Industrial Security (http://www.siemens.com/industrialsecurity)". ● Inform yourself regularly about security advisories and bulletins published by Siemens ProductCERT (http://www.siemens.com/cert/en/cert-security-advisories.htm). ● Only activate protocols that you really require to use the device.
Page 8
● Verify certificates and fingerprints on the server and client to avoid "man in the middle" attacks. ● We recommend that you use certificates with a key length of 2048 bits. ● Change keys and certificates immediately, if there is a suspicion of compromise. SCALANCE W774-1 /W734-1 Operating Instructions, 01/2017, C79000-G8976-C325-08...
Page 9
● If you require non-secure protocols and services, operate the device only within a protected network area. ● Restrict the services and protocols available to the outside to a minimum. SCALANCE W774-1 /W734-1 Operating Instructions, 01/2017, C79000-G8976-C325-08...
Page 10
UDP/49154, 49155 Syslog UDP/514 Open (when configured) Open EtherNet/IP TCP/44818, Open (when configured) Open UDP/2222,4481 DHCP UDP/67,68 Open (when configured) Closed RADIUS UDP/1812,1813 Open (when configured) Closed TFTP UDP/69 Open (when configured) Closed SCALANCE W774-1 /W734-1 Operating Instructions, 01/2017, C79000-G8976-C325-08...
Description of the device 3.2 Structure of the type designation Structure of the type designation The type designation of the device is made up of several parts that have the following meaning: SCALANCE W774-1 /W734-1 Operating Instructions, 01/2017, C79000-G8976-C325-08...
● 1 screw for mounting on an S7-300 standard rail or S7-1500 standard rail ● SIMATIC NET Industrial Wireless LAN CD Please check that the consignment you have received is complete. If the consignment is incomplete, contact your supplier or your local Siemens office. SCALANCE W774-1 /W734-1 Operating Instructions, 01/2017, C79000-G8976-C325-08...
Flexible bus cable, TPE outer jacket for connec- 6XV1 841-2B FLEXIBLE CABLE GP tion to FC RJ-45 PLUG and FC OUTLET RJ-45, flexible wires, 4-wire, shielded, CAT 5 (PROFINET type B) Sold by the meter SCALANCE W774-1 /W734-1 Operating Instructions, 01/2017, C79000-G8976-C325-08...
Page 16
4.5 mm, two N-Connect female con- male/female Panel nectors. Feedthrough N-Connect/SMA- Panel feedthrough for wall thicknesses up to a 6GK5 798-0PT00-2AA6 Connect fe- maximum of 5.5 mm, two N-Connect/SMA female male/female Panel connectors. Feedthrough SCALANCE W774-1 /W734-1 Operating Instructions, 01/2017, C79000-G8976-C325-08...
Page 17
Lighting protector with N/N female/female connector with 6GK5798-2LP00-2AA6 gas discharge technology LP798-2N Lighting protector with N/N female/female connector with 6GK5798-2LP10-2AA6 quarter wave technology Terminating resistor Component Description Article number TI795-1N Electrical connection 6GK5795-1TN00-1AA0 N-Connect, male SCALANCE W774-1 /W734-1 Operating Instructions, 01/2017, C79000-G8976-C325-08...
Flexible connecting cable for connecting an antenna to a SCALANCE W700 with N-Connect connectors. Preassembled with two N male connectors: Length Article number 6XV1875-5AH10 6XV1875-5AH20 6XV1875-5AH50 10 m 6XV1875-5AN10 For railway applications, the following connecting cable are available: Length Article number 6XV1875-5SH10 6XV1875-5SH20 6XV1875-5SH50 SCALANCE W774-1 /W734-1 Operating Instructions, 01/2017, C79000-G8976-C325-08...
Page 21
The antenna ANT793-8DK may only be used with the flexible connecting cable 6XV1875- 5CN10 (10 m length). Other flexible connecting cables are not permitted. Notice for USA/Canada Only one antenna per device can be used (connected to R1A1, R1A2 or R2A1, R2A2). SCALANCE W774-1 /W734-1 Operating Instructions, 01/2017, C79000-G8976-C325-08...
Data transfer via the first Ethernet interface. low flashing alternately Green There is a connection via the second Ethernet interface (Link). Green and yel- Data transfer via the second Ethernet interface. low flashing alternately SCALANCE W774-1 /W734-1 Operating Instructions, 01/2017, C79000-G8976-C325-08...
Page 23
If no primary user is detected, data traffic is possible again. The wait time of 30 minutes is necessary due to legal requirements and cannot be shortened even by restarting the device. SCALANCE W774-1 /W734-1 Operating Instructions, 01/2017, C79000-G8976-C325-08...
Loss of water and dust protection If the cover is not mounted correctly, the device is not water and dust proof. ① The reset button (position ) is on the top of the housing: SCALANCE W774-1 /W734-1 Operating Instructions, 01/2017, C79000-G8976-C325-08...
Page 25
If you reset, all the changes you have made will be overwritten by factory defaults. NOTICE Inadvertent reset An inadvertent reset can cause disturbances and failures in the configured network with further consequences. SCALANCE W774-1 /W734-1 Operating Instructions, 01/2017, C79000-G8976-C325-08...
Page 26
Description of the device 3.6 Reset button SCALANCE W774-1 /W734-1 Operating Instructions, 01/2017, C79000-G8976-C325-08...
General notes on use according to ATEX and IECEx WARNING To comply with EC Directive 2014/34/EU (ATEX 114) or the conditions of IECEx, this enclosure or cabinet must meet the requirements of at least IP54 in compliance with EN 60529. SCALANCE W774-1 /W734-1 Operating Instructions, 01/2017, C79000-G8976-C325-08...
Mounting 4.1 Wall mounting Wall mounting Drilling template The location of the holes for mounting the SCALANCE W774/W734 on a wall is shown in the following figure: SCALANCE W774-1 /W734-1 Operating Instructions, 01/2017, C79000-G8976-C325-08...
Page 29
2. Secure the device to the wall with two screws (M4). The screws are not supplied with the device. The type and length of the screws depend on the type of wall. 3. Mount the connecting cables and the antenna, see section "Connecting up (Page 35)". SCALANCE W774-1 /W734-1 Operating Instructions, 01/2017, C79000-G8976-C325-08...
1. Place the device on the upper edge of the S7-300 standard rail as shown in the figure. 2. Screw the housing to the S7-300 standard rail. The required screw ships with the SCALANCE W774/W734. 3. Mount the connecting cables and the antenna, see section "Connecting up (Page 35)". SCALANCE W774-1 /W734-1 Operating Instructions, 01/2017, C79000-G8976-C325-08...
1. Place the device on the upper edge of the S7-1500 standard rail as shown in the figure. 2. Screw the housing to the S7-1500 standard rail. The required screw ships with the device. 3. Mount the connecting cables and the antenna, see section "Connecting up (Page 35)". SCALANCE W774-1 /W734-1 Operating Instructions, 01/2017, C79000-G8976-C325-08...
1. Place the device on the upper edge of the DIN rail as shown in the figure. 2. Press the device against the DIN rail until the DIN rail slider catch locks in place. 3. Mount the connecting cables and the antenna, see section "Connecting up (Page 35)". SCALANCE W774-1 /W734-1 Operating Instructions, 01/2017, C79000-G8976-C325-08...
Page 33
1. Turn off the power to the device. 2. Disconnect all connected cables. 3. Pull the DIN rail slider down with a screwdriver. 4. Tilt the SCALANCE W774/W734 forward and remove the device from the DIN rail. SCALANCE W774-1 /W734-1 Operating Instructions, 01/2017, C79000-G8976-C325-08...
Page 34
Mounting 4.4 Installing on a DIN rail / removing SCALANCE W774-1 /W734-1 Operating Instructions, 01/2017, C79000-G8976-C325-08...
Note Close unused sockets Close all unused M12 sockets with protective caps (torque at least 0.4 Nm) to achieve the specified type of protection. SCALANCE W774-1 /W734-1 Operating Instructions, 01/2017, C79000-G8976-C325-08...
The requirements of EN61000-4-5, surge immunity tests on power supply lines, are met only when a Blitzductor is used with 24 VDC: BVT AVD 24 type no. 918 422 Manufacturer: DEHN+SÖHNE GmbH+Co.KG, Hans Dehn Str. 1, Postfach 1640, D - 92306 Neumarkt, Germany SCALANCE W774-1 /W734-1 Operating Instructions, 01/2017, C79000-G8976-C325-08...
Page 37
• Housing of the SCALANCE W700 and the ground potential of a device connected over Ethernet. • Housing of the SCALANCE W700 and the shield contact of the connected Ethernet cable. Connect both grounds to the same foundation earth or use an equipotential bonding cable. SCALANCE W774-1 /W734-1 Operating Instructions, 01/2017, C79000-G8976-C325-08...
Page 38
This equipment is suitable for use in Class I, Division 2, Groups A, B, C and D or non- hazardous locations only. This equipment is suitable for use in Class I, Zone 2, Group IIC or non-hazardous locations only. SCALANCE W774-1 /W734-1 Operating Instructions, 01/2017, C79000-G8976-C325-08...
● Power over Ethernet via the RJ-45 Ethernet interface P2 (position ). The other Ethernet interface P1 is not capable of PoE. The four-pin connecting socket has the following pin assignment: Assignment 24 VDC Ground SCALANCE W774-1 /W734-1 Operating Instructions, 01/2017, C79000-G8976-C325-08...
Page 40
● Power over Ethernet via the M12 Ethernet interface P2 (position ). The other Ethernet interface P1 is not capable of PoE. The four-pin M12 socket has the following pin assignment: Signal Assignment 24 VDC 24 VDC Ground Ground SCALANCE W774-1 /W734-1 Operating Instructions, 01/2017, C79000-G8976-C325-08...
Page 41
Ethernet cables with M12 connectors for the SCALANCE W788-x M12 (Gigabit Ethernet, eight-wire) cannot be used for the SCALANCE W774 M12 EEC. Note No power sourcing equipment (PSE) The SCALANCE W774/W734 devices cannot be used as a PoE power supply for other devices. SCALANCE W774-1 /W734-1 Operating Instructions, 01/2017, C79000-G8976-C325-08...
The power can also be supplied via this interface (Power over Ethernet). SCALANCE W774/W734 M12 EEC ① Ethernet interface P1 ② Ethernet interface P2 The power can also be supplied via this interface (Power over Ethernet). SCALANCE W774-1 /W734-1 Operating Instructions, 01/2017, C79000-G8976-C325-08...
Page 43
Connection 5.3 Ethernet The four-pin connecting socket has the following pin assignment: Assignment SCALANCE W774-1 /W734-1 Operating Instructions, 01/2017, C79000-G8976-C325-08...
Within the area of authority of the NEC and CEC, the SCALANCE W770/W730 devices and the antennas connected to them may only be used in a closed building. For this reason, do not lead antennas into the outdoor area if you need to meet UL requirements. SCALANCE W774-1 /W734-1 Operating Instructions, 01/2017, C79000-G8976-C325-08...
Page 45
When installing the SCALANCE W770/W730 in a cabinet, you need to use detached antennas. A suitable flexible connecting cable for a connection between SCALANCE W778/W738 and a detached antenna are available from SIMATIC NET. You will find detailed information in the section AUTOHOTSPOT. SCALANCE W774-1 /W734-1 Operating Instructions, 01/2017, C79000-G8976-C325-08...
PLUG inserted, the SCALANCE W700 starts up with the configuration data on the PLUG. Position The PLUG slot is on the top of the device housing under a cover, see Reset button (Page 24). SCALANCE W774-1 /W734-1 Operating Instructions, 01/2017, C79000-G8976-C325-08...
Page 47
The reset button is directly beside the slot for the PLUG. The reset button cannot be used to remove the PLUG. If you press and hold down the reset button you reset all the settings of the device to the factory defaults. SCALANCE W774-1 /W734-1 Operating Instructions, 01/2017, C79000-G8976-C325-08...
Page 48
A C-PLUG only stores information about the configuration of a device. In addition to the configuration, a KEY-PLUG also contains a license with which you can enable special functions, for example iFeatures. You will find the article numbers in Accessories (Page 15). SCALANCE W774-1 /W734-1 Operating Instructions, 01/2017, C79000-G8976-C325-08...
Connect the paint-free surface of the device to the nearest grounding point using the grounding cable. Grounding when installing on a DIN rail / S7 standard rail The device is grounded via the rear of the device. SCALANCE W774-1 /W734-1 Operating Instructions, 01/2017, C79000-G8976-C325-08...
Once the firmware has been transferred completely to the device, there is an automatic restart on the device. This process can take several minutes. 11.Close the cover (tightening torque 0.8 Nm), to ensure that the device is closed and water and dust proof. SCALANCE W774-1 /W734-1 Operating Instructions, 01/2017, C79000-G8976-C325-08...
You will find detailed information on resetting the device parameters using the WBM and CLI in the configuration manuals: ● Web Based Management, section "Restart" ● Command Line Interface, section "Reset and Defaults" SCALANCE W774-1 /W734-1 Operating Instructions, 01/2017, C79000-G8976-C325-08...
Technical data Technical specifications W774/W734 RJ-45 The following technical specifications apply to the following devices: ● SCALANCE W774-1 RJ-45 ● SCALANCE W734-1 RJ-45 Note You will find detailed information on the transmit power and receiver sensitivity in the document "Performance data 802.11 abgn SCALANCE W770/W730" on the supplied data medium (REF_W770-RadioInterface.pdf).
Page 54
According to IEC 60721 Design, dimensions and weight Degree of protection IP30 Weight 520 g Dimensions (W x H x D) 26 x 156 x 127 mm (height without antenna connector 147 mm) SCALANCE W774-1 /W734-1 Operating Instructions, 01/2017, C79000-G8976-C325-08...
Page 55
61.85 years The PoE class depends on the hardware version of the device. Devices with a hardware version ≥ 3 have PoE class 2. Devices with a lower hardware version have PoE class 3. SCALANCE W774-1 /W734-1 Operating Instructions, 01/2017, C79000-G8976-C325-08...
7.2 Technical specifications W774 M12 Technical specifications W774 M12 The following technical specifications apply to the following devices: ● SCALANCE W774-1 M12 EEC Note You will find detailed information on the transmit power and receiver sensitivity in the document "Performance data 802.11 abgn SCALANCE W770/W730" on the supplied data medium (REF_W770-RadioInterface.pdf).
Page 57
61.85 years The PoE class depends on the hardware version of the device. Devices with a hardware version ≥ 2 have PoE class 2. Devices with a lower hardware version have PoE class 3. SCALANCE W774-1 /W734-1 Operating Instructions, 01/2017, C79000-G8976-C325-08...
Approvals You will find the approvals of the products in the reference work "Approvals SCALANCE W700 802.11n" on the Internet pages of Siemens Industry Online Support: ● Using the search function: support.automation.siemens.com (http://support.automation.siemens.com/WW/view/en) Enter the entry ID of the relevant manual as the search item.