Siemens SCALANCE W786-1PRO Operating Instructions Manual

Siemens SCALANCE W786-1PRO Operating Instructions Manual

Industrial wireless lan outdoor access point
Hide thumbs Also See for SCALANCE W786-1PRO:

Advertisement

Quick Links

SCALANCE W786 outdoor access point
SIMATIC NET
Industrial Wireless LAN
SCALANCE W786 outdoor access
point
Operating Instructions
06/2013
A5E02280428-08
___________________
Information on the Internet
___________________
Safety instructions
___________________
Introduction
___________________
Description
___________________
Mounting
___________________
Connecting up
___________________
Technical specifications
___________________
Certification
1
2
3
4
5
6
7
8

Advertisement

Table of Contents
loading

Summary of Contents for Siemens SCALANCE W786-1PRO

  • Page 1 ___________________ SCALANCE W786 outdoor access point Information on the Internet ___________________ Safety instructions ___________________ Introduction SIMATIC NET ___________________ Description Industrial Wireless LAN ___________________ SCALANCE W786 outdoor access Mounting point ___________________ Connecting up Operating Instructions ___________________ Technical specifications ___________________ Certification 06/2013 A5E02280428-08...
  • Page 2 Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
  • Page 3: Table Of Contents

    Contents Information on the Internet ........................5 Safety instructions ........................... 7 General safety information for the SCALANCE W786 ..............7 Introduction ............................. 9 Information on the Operating Instructions ..................9 Type designations ........................10 Description ............................13 Scope of delivery.......................... 13 LED display ..........................
  • Page 4 Contents Permitted antennas ........................60 Radiation patterns diagrams of SCALANCE W786 internal antennas ........61 Certification ............................65 Approvals for SCALANCE W786 ....................65 National approvals ........................77 SCALANCE W786 outdoor access point Operating Instructions, 06/2013, A5E02280428-08...
  • Page 5: Information On The Internet

    Information on the Internet Bitte beachten Sie die Warnhinweise und zusätzlichen Informationen in der Betriebsanleitung (kompakt) in Ihrer Sprache im Internet: http://support.automation.siemens.com/ww/view/at/10806097 http://support.automation.siemens.com/ww/view/ch/10806097 http://support.automation.siemens.com/ww/view/de/10806097 http://support.automation.siemens.com/ww/view/li/10806097 http://support.automation.siemens.com/ww/view/lu/10806097 Please observe the warnings and additional information in the user manual (compact) in your language in the Internet: http://support.automation.siemens.com/ww/view/au/10806097...
  • Page 6 以下のインターネットアドレスでお客様の言語による取扱説明書(コンパクト版)をご覧 http://support.automation.siemens.com/ww/view/jp/10806097 いただけます。同取扱説明書内に記載された警告事項および補足情報にご注意ください。 인터넷 http://support.automation.siemens.com/ww/view/kr/10806097에서 귀하의 사용 언어로 된 사용자 설명서(컴팩트)의 경고 및 추가 정보를 확인하십시오. ‫ىلإ هبنتلا بجي‬ ‫صخلملا ليغشتلا ليلد يف ةروكذملا ةيفاضإلا تامولعملا و ريذحتلا ثاداشرا‬ ‫يف ةروكذملا ةيفاضإلا تامولعملا و ريذحتلا تنرتنالا ةكبش ىلع دوجوملا و مكتغلب‬...
  • Page 7: Safety Instructions

    Safety instructions General safety information for the SCALANCE W786 WARNING Danger from line voltage After removing the housing cover, there is a risk of touching live parts in the area of the connecting terminals of the power supply adapter. Only authorized personnel is permitted to open the device and carry out any work on the open device (e.g.
  • Page 8 Safety instructions 2.1 General safety information for the SCALANCE W786 SCALANCE W786 outdoor access point Operating Instructions, 06/2013, A5E02280428-08...
  • Page 9: Introduction

    Introduction Information on the Operating Instructions Validity of the Operating Instructions (compact) These operating instructions cover the following products: ● SCALANCE W786-1PRO ● SCALANCE W786-2PRO ● SCALANCE W786-3PRO ● SCALANCE W786-2RR These operating instructions apply to the following software version: ●...
  • Page 10: Type Designations

    Introduction 3.2 Type designations Type designations Abbreviations used The information in the manuals for the SCALANCE W-700 product family often applies to more than one product variant. In such situations, the designations of the products are shortened to avoid having to list all the type designations. The following table shows how the abbreviations relate to the product variants.
  • Page 11 Introduction 3.2 Type designations Product group The designation . . . stands Product name for . . . All SCALANCE W access points W78x W788-1PRO W788-2PRO W788-1RR W788-2RR W786-1PRO W786-2PRO W786-3PRO W786-2RR W784-1 W784-1RR All SCALANCE W devices W -700 W788-1PRO W788-2PRO W788-1RR...
  • Page 12 Introduction 3.2 Type designations SCALANCE W786 outdoor access point Operating Instructions, 06/2013, A5E02280428-08...
  • Page 13: Description

    Description Scope of delivery LED display Information on operating status and data transfer On the front of the housing, several LEDs provide information on the operating status of the SCALANCE W786: Figure 4-1 The LED display of the SCALANCE W786 Note The "PoE"...
  • Page 14 Description 4.2 LED display Color Meaning Green Power supply over a power supply adapter or the 48 V DC energy contacts of devices with a port for FO cable. Green Power over Ethernet or power over the 48 V DC energy contacts of devices with an RJ-45 port.
  • Page 15 Description 4.2 LED display Color Meaning Access Point Mode: Green flashing quickly With 802.11h, the channel is scanned for one minute for primary users before the channel can be used for data traffic. Client Mode: The LED is always off because the 2nd port is not available in client mode.
  • Page 16 Description 4.2 LED display Note If the LED for the WLAN port is not green when the device starts up, although it is activated, the port is not ready for operation (interface not initialized). The main reason for this is usually that during commissioning of the SCALANCE W78x products, a waiting time of up to 15 minutes can occur when the ambient temperature is below zero.
  • Page 17: Reset Button

    Description 4.3 Reset button Reset button WARNING Danger from line voltage Once you have removed the housing cover, there is the danger from line voltage in the area of the connecting terminals on the power supply adapter. Only authorized personnel is permitted to open the device and carry out any work on the open device (e.g.
  • Page 18 Description 4.3 Reset button SCALANCE W786 outdoor access point Operating Instructions, 06/2013, A5E02280428-08...
  • Page 19: Mounting

    Mounting Removing / fitting the housing cover When does the housing cover need to be removed? You can only perform the following activities when the cover is removed. ● You want to screw the SCALANCE W786 to a wall or onto the optional mounting plate. ●...
  • Page 20 Mounting 5.1 Removing / fitting the housing cover Figure 5-1 Removing the cover A Sealing cap B Cover screw C Housing cover Follow the steps below to remove the housing cover: 1. Remove the sealing caps from the housing cover (position A in the figure above) 2.
  • Page 21: Connecting Up Cables

    Mounting 5.2 Connecting up cables Connecting up cables Connecting up cables prior to mounting Before you screw a SCALANCE W786 to a wall or to the optional mounting plate, the cables for the power supply, for Ethernet, and, when necessary, for the external antennas must be connected up first.
  • Page 22 Mounting 5.2 Connecting up cables Connecting up FO cables Fiber-optic cables have a minimum bending radius. The cable must not be bent tighter than this bending radius during installation or operation, otherwise the FO cable will be irreperably damaged. Figure 5-3 Connecting up an FO cable For the FO cable, use the second opening from the left in the seal.
  • Page 23 Mounting 5.2 Connecting up cables Grounding terminal WARNING To operate the SCALANCE W786 safely, the chassis ground connector must have a suitable cable connected. Do not use the SCALANCE W786 without a ground cable connected. The chassis ground connector is located on the rear of the device (M4 thread). Connect the ground cable before you mount the SCALANCE W786 on a wall or on the optional mounting plate.
  • Page 24: Mounting Without An Adapter (Wall Mounting Only)

    Mounting 5.3 Mounting without an adapter (wall mounting only) Mounting without an adapter (wall mounting only) Drilling template Note Installation location The following should be noted with regard to the installation location: • Devices with an internal antenna must be aligned according to the characteristics of the internal antenna (refer to the technical specifications of the antenna -->...
  • Page 25 Mounting 5.3 Mounting without an adapter (wall mounting only) Procedure Figure 5-6 SCALANCE W786 wall mounting Follow the steps below to screw a SCALANCE W786 to a wall: 1. Lead the cables into the housing of the SCALANCE W786 (position A in the figure above).
  • Page 26: Mounting With Mounting Plate

    Mounting 5.4 Mounting with mounting plate Mounting with mounting plate 5.4.1 Fitting the mounting plate to a wall Drilling template Note Installation location The following should be noted with regard to the installation location: • Devices with an internal antenna must be aligned according to the characteristics of the internal antenna (refer to the technical specifications of the antenna -->...
  • Page 27 Mounting 5.4 Mounting with mounting plate Procedure Secure the mounting plate to the wall with four screws. The screws are not supplied with the device. The type and length of the screws depend on the type of wall. Type of screw: ●...
  • Page 28: Screwing The Cover Plate For The Cable Feedthrough To The Mounting Plate

    Mounting 5.4 Mounting with mounting plate 5.4.2 Screwing the cover plate for the cable feedthrough to the mounting plate Protection of the cable feedthrough against strong water jets The cabling of a SCALANCE W786 is led out of the rear of the device. The housing seal is effective only when it is not subjected to water jets.
  • Page 29: Fitting The Mounting Plate To An S7-300 Standard Rail

    Mounting 5.4 Mounting with mounting plate To screw the cover plate for the cable feedthrough to the mounting plate, follow the steps below: 1. Fit the cover plate on the mounting plate from below until the two lugs (position A in the figure above) engage the lower edge of the mounting plate.
  • Page 30: Fitting The Mounting Plate To A Din Rail

    Mounting 5.4 Mounting with mounting plate 5.4.4 Fitting the mounting plate to a DIN rail NOTICE No DIN rail mounting when used on ships If the SCALANCE W786 is used on ships, the DIN rail mounting is not adequate to hold the device in place.
  • Page 31: Fitting The Mounting Plate To A Mast

    Mounting 5.4 Mounting with mounting plate 5.4.5 Fitting the mounting plate to a mast Procedure Figure 5-12 Mounting plate with fittings for mast mounting Follow the steps below to fit the mounting plate to a mast: 1. Feed the fastening straps through the openings in the mounting plate (position A in the figure above).
  • Page 32: Fitting/Removing The Scalance W786 To/From A Mounting Plate

    Mounting 5.4 Mounting with mounting plate 5.4.6 Fitting/removing the SCALANCE W786 to/from a mounting plate Procedure for mounting the device Figure 5-13 Fitting the SCALANCE W786 to a mounting plate Follow the steps below to fit a SCALANCE W786 to a mounting plate: 1.
  • Page 33 Mounting 5.4 Mounting with mounting plate 3. Push in the SCALANCE W786 until it engages in the notches at the lower edge of the mounting plate (position C in the figure above). Figure 5-14 Screwing a SCALANCE W786 to a mounting plate 4.
  • Page 34 Mounting 5.4 Mounting with mounting plate SCALANCE W786 outdoor access point Operating Instructions, 06/2013, A5E02280428-08...
  • Page 35: Connecting Up

    Connecting up Lightning protection, power supply, and grounding Notes on lightning protection WARNING Danger due to lightning strikes Antennas installed outdoors must be within the area covered by a lightning protection system. Make sure that all conducting systems entering from outdoors can be protected by a lightning protection potential equalization system.
  • Page 36 Connecting up 6.1 Lightning protection, power supply, and grounding Note 48 V lightning protector When using the 48 V DC lightning protector, the power supply must be fused with 1 A. Safety extra low voltage WARNING Danger to life from overvoltage, fire hazard The equipment is designed for operation with Safety Extra Low Voltage, SELV by a Limited Power Source, LPS.
  • Page 37 Connecting up 6.1 Lightning protection, power supply, and grounding Power supply without power grid To operate the device without a connection to the power grid, you can use a solar panel. The company Solis Energy (www.solisenergy.com) offers suitable solutions. The size of the panel required depends on the daily hours of sunlight.
  • Page 38 Connecting up 6.1 Lightning protection, power supply, and grounding Notes on operating the device in a hazardous area WARNING EXPLOSION HAZARD DO NOT CONNECT OR DISCONNECT EQUIPMENT WHEN A FLAMMABLE OR COMBUSTIBLE ATMOSPHERE IS PRESENT. WARNING EXPLOSION HAZARD SUBSTITUTION OF COMPONENTS MAY IMPAIR SUITABILITY FOR CLASS I, DIVISION 2 OR ZONE 2.
  • Page 39 Connecting up 6.1 Lightning protection, power supply, and grounding Special notes for the SCALANCE W786-xPRO/RR Warning Notices cULus haz.loc. This equipment is suitable for use in Class I, Division 2, Groups A, B, C, D; Class I, Zone 2, Group IIC or non-hazardous locations. WARNING - Cat.
  • Page 40: Suitable Cables For The Scalance W786

    Connecting up 6.2 Suitable cables for the SCALANCE W786 Suitable cables for the SCALANCE W786 Cable specification The following table lists the requirements for a cable depending on the use case. Application Specification Direct 48 V DC supply Round cable cross-section with •...
  • Page 41 Connecting up 6.2 Suitable cables for the SCALANCE W786 WARNING If temperatures in excess of 70° occur on the cable or at the housing socket, or the temperature at the branching points of the cables exceeds 80°, special measures need to be taken.
  • Page 42: Connecting The Cables

    Connecting up 6.3 Connecting the cables Connecting the cables Procedure WARNING Danger from line voltage If the housing is not perfectly sealed, there is a danger to life due to the line voltage if the SCALANCE W786 is subjected to spray water or dampness. Make sure that you keep to the following safety rules.
  • Page 43 Connecting up 6.3 Connecting the cables Figure 6-1 Connecting a cable and fitting the strain relief clamps Follow the steps below to connect cables to the SCALANCE W786: 1. Connect the cables to the appropriate contacts. (Position A in the figure above) You have the following options: –...
  • Page 44 Connecting up 6.3 Connecting the cables 4. Seal all openings not required for cables with sealing plugs (position D in the figure above). 5. Fit these sealing plugs in a strain relief clamp. The lower surrounding notch must be enclosed by the toothing of the strain relief clamp (as shown in the figure below). Press the strain relief clamp into the housing until the sealing plug is located completely in the opening of the housing seal.
  • Page 45: Connectors For The Power Supply Of The Scalance W786

    Connecting up 6.4 Connectors for the power supply of the SCALANCE W786 Figure 6-3 View from above with an FO cable inserted in the strain relief clamp Connectors for the power supply of the SCALANCE W786 Possible power supplies The following power supplies are suitable for the SCALANCE W786: ●...
  • Page 46 Connecting up 6.4 Connectors for the power supply of the SCALANCE W786 Procedure for connecting the supplied connector for 48 VDC Figure 6-4 Position of the opening in the housing for the power supply with the housing cover removed Perform the following steps to connect a 48 VDC cable to a SCALANCE W786: 1.
  • Page 47: Connecting A Power Supply Adapter

    Connecting up 6.5 Connecting a power supply adapter Connecting a power supply adapter Input voltage options The optional power supply adapter is available in two versions: ● Power supply adapter for 12 - 24 V DC direct voltage ● Power supply adapter for 100 - 240 V AC alternating voltage Note Applies only to SCALANCE W786-3xx If a SCALANCE W786-3xx is operated with diversity for three antenna pairs, the power...
  • Page 48 Connecting up 6.5 Connecting a power supply adapter NOTICE Exceeding the EMC limit values • SCALANCE W786 with RJ-45 interface with DC power supply adapter or without power supply adapter When using a SCALANCE W786 with RJ-45 connector without a power supply adapter or with a DC power adapter, no additional measures are necessary for use in a residential environment.
  • Page 49 Connecting up 6.5 Connecting a power supply adapter Figure 6-6 Using a power supply adapter in a SCALANCE W786 Follow the steps below to fit and connect a power supply adapter: 1. Fit the power supply adapter in the SCALANCE W786 as shown in the figure above. The connector on the rear of the power supply adapter must engage fully in the socket of the housing.
  • Page 50 Connecting up 6.5 Connecting a power supply adapter The following applies to the PS791-2AC (AC 100 – 240 V) only: WARNING Danger from line voltage The strain relief clamp may damage the insulation under unfavorable circumstances. You run the risk of encountering danger from line voltage through the strain relief clamp. For a line with 100 to 240 VAC use an insulated strain relief clamp only;...
  • Page 51: Connection For Industrial Ethernet

    Connecting up 6.6 Connection for Industrial Ethernet Connection for Industrial Ethernet Device variants With a SCALANCE W786, you have the choice of two Ethernet ports: ● RJ-45 jack ● ST duplex socket for multimode FO cables 1310 nm and a maximum cable length of 3000 Procedure for connecting an Ethernet cable Figure 6-7 Position of the Ethernet port with the housing cover removed...
  • Page 52: Connectors For External Antennas

    For each WLAN port, there are two R-SMA sockets on a SCALANCE W786 to connect external antennas. The figure above shows how the R-SMA sockets are assigned to the WLAN ports. With a SCALANCE W786-1PRO, only the socket pair labeled "1" exists; with a SCALANCE W786-2PRO the sockets labeled "1" and "2" exist.
  • Page 53: Inserting / Removing The C-Plug

    Connecting up 6.8 Inserting / removing the C-PLUG Inserting / removing the C-PLUG WARNING Danger from line voltage Once you have removed the housing cover, there is the danger from line voltage in the area of the connecting terminals on the power supply adapter. Only authorized personnel is permitted to open the device and carry out any work on the open device (e.g.
  • Page 54 Connecting up 6.8 Inserting / removing the C-PLUG Removing the C-PLUG Follow the steps below to remove a C-PLUG from the device: 1. Turn off the power to the device. 2. Remove the housing cover, see section "Removing/fitting the housing cover". 3.
  • Page 55: Technical Specifications

    SCALANCE W786 technical specifications Product versions ● SCALANCE W786-1PRO with one wireless interface and in the variants with two internal antennas or two external antenna connectors and with RJ-45 or FO connector ● SCALANCE W786-2PRO with two wireless interfaces and in the variants with four internal antennas or four external antenna connectors and with RJ-45 or FO connector ●...
  • Page 56 Technical specifications 7.1 SCALANCE W786 technical specifications Interfaces Power • 48 VDC power supply (minimum permitted voltage 36 VDC, maximum permitted voltage 57 VDC) via supplied connector • RJ-45 jack Power over Ethernet 48 VDC (minimum permitted voltage 36 VDC, maximum permitted voltage 57 VDC) •...
  • Page 57 Technical specifications 7.1 SCALANCE W786 technical specifications Permitted ambient conditions Operating temperature -40°C to +70°C Operation with 100 V to 240 V power supply -40°C to +60°C You should also note the temperature ranges specified in the approvals. Transportation/storage temperature -40°C to +85°C Degree of protection Tested to IP65...
  • Page 58 Technical specifications 7.1 SCALANCE W786 technical specifications Table 7- 3 Transmit power in IEEE 802.11a/h mode (5 GHz) Data rate [Mbps] [dBm] 13.5 Receiver sensitivity Table 7- 4 Receiver sensitivity in IEEE 802.11b mode (2.4 GHz) Data rate [Mbps] [dBm] Table 7- 5 Receiver sensitivity in IEEE 802.11g mode (2.4 GHz) Data rate [Mbps]...
  • Page 59: Dimension Drawing Scalance W786

    Technical specifications 7.2 Dimension drawing SCALANCE W786 Table 7- 6 Receiver sensitivity in IEEE 802.11a/h mode (5 GHz) Data rate [Mbps] [dBm] Dimension drawing SCALANCE W786 Front view and view from above of the SCALANCE W786 SCALANCE W786 outdoor access point Operating Instructions, 06/2013, A5E02280428-08...
  • Page 60: Permitted Antennas

    Technical specifications 7.3 Permitted antennas Permitted antennas Accessories for SCALANCE W-700 Note When you select an antenna, keep in mind the national approvals for your SCALANCE W7xx. Characteristics Type Frequency / Antenna gain / Impedance / Ω Order No. Omni ANT795-6MN 6GK5795- 6MN00-0AA6...
  • Page 61: Radiation Patterns Diagrams Of Scalance W786 Internal Antennas

    Technical specifications 7.4 Radiation patterns diagrams of SCALANCE W786 internal antennas Radiation patterns diagrams of SCALANCE W786 internal antennas Horizontal radiation pattern 2500 MHz SCALANCE W786 outdoor access point Operating Instructions, 06/2013, A5E02280428-08...
  • Page 62 Technical specifications 7.4 Radiation patterns diagrams of SCALANCE W786 internal antennas Vertical radiation pattern 2500 MHz Horizontal radiation pattern 5800 MHz SCALANCE W786 outdoor access point Operating Instructions, 06/2013, A5E02280428-08...
  • Page 63 Technical specifications 7.4 Radiation patterns diagrams of SCALANCE W786 internal antennas Vertical radiation pattern 5800 MHz SCALANCE W786 outdoor access point Operating Instructions, 06/2013, A5E02280428-08...
  • Page 64 Technical specifications 7.4 Radiation patterns diagrams of SCALANCE W786 internal antennas SCALANCE W786 outdoor access point Operating Instructions, 06/2013, A5E02280428-08...
  • Page 65: Certification

    SIMATIC NET SCALANCE W786-2PRO SIMATIC NET SCALANCE W786-3PRO SIMATIC NET SCALANCE W786-2RR in the version put into circulation by Siemens AG meet the regulations of the following European directives: ● 99/5/EC Directive of the European Parliament and of the Council on radio equipment and telecommunications terminal equipment and the mutual recognition of their conformity.
  • Page 66 Devices connected to the system must meet the relevant safety regulations. The EC Declaration of Conformity is available for the responsible authorities according to the above-mentioned EC Directive at the following address: Siemens Aktiengesellschaft Industry Sector Postfach 4848 D-90026 Nürnberg This declaration certifies compliance with the directives named above, but does not guarantee any specific properties.
  • Page 67 Certification 8.1 Approvals for SCALANCE W786 ATEX, FM and cULus approvals The products SCALANCE W786-1PRO SCALANCE W786-2PRO SCALANCE W786-3PRO SCALANCE W786-2RR have the following approvals ● EN 60079-15 : 2005 EN 60079-0 : 2006 II 3 G Ex nA II T4 KEMA 07 ATEX 0145 X Ta: -40 °C to +60 ℃...
  • Page 68 Certification 8.1 Approvals for SCALANCE W786 SCALANCE W786-1PRO SCALANCE W786-2PRO SCALANCE W786-3PRO SCALANCE W786-2RR meet the stipulations of the following directives or standards: ● Directive 72/245/EC, last changed by directive 2006/28/EC Type approval number e1*72/245*2006/28*5311*00 E1: Number of approval 025311...
  • Page 69 Certification 8.1 Approvals for SCALANCE W786 Certification ID The following table shows the product names and the corresponding certification ID: Type Number and type of Number of Number of R-SMA Certification ID Ethernet ports internal antennas sockets for external Order no. antennas Order no.
  • Page 70 Certification 8.1 Approvals for SCALANCE W786 SCALANCE W786 outdoor access point Operating Instructions, 06/2013, A5E02280428-08...
  • Page 71 ___________________________________________________________________________ Notice Changes or modifications made to this equipment not expressly approved by SIEMENS may void the FCC authorization to operate this equipment. ___________________________________________________________________________ This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules.
  • Page 72 Certification 8.1 Approvals for SCALANCE W786 To comply with FCC part 15 rules in the United States, the system must be professionally installed to ensure compliance with the Part 15 certification. It is the responsibility of the operator and professional installer to ensure that only certified systems are deployed in the United States.
  • Page 73 Certification 8.1 Approvals for SCALANCE W786 NCC Warning Statement (Taiwan) Article 12 Without permission, any company, firm or user shall not alter the frequency, increase the power, or change the characteristics and functions of the original design of the certified lower power frequency electric machinery. Article 14 The application of low power frequency electric machineries shall not affect the navigation safety nor interfere a legal communication, if an interference is...
  • Page 74 Certification 8.1 Approvals for SCALANCE W786 Certification ID Certification number EAP-W2-RJ-E2 RCPSIEA08-0713-A2 EAP-W2-RJ-I2 RCPSIEA08-0713-A3 EAP-W2-MM-E2 RCPSIEA08-0713-A7 EAP-W2-MM-I2 RCPSIEA08-0713-A8 EAP-W3-RJ-E3 RCPSIEA08-0713-A4 EAP-W3-MM-E3 RCPSIEA08-0713-A9 Notes on approval in Argentina Certification ID Certification number EAP-W1-RJ-E1 CNC:C-6884 EAP-W1-RJ-I1 CNC:C-6881 EAP-W1-MM-E1 CNC:C-6876 EAP-W1-MM-I1 CNC:C-6875 EAP-W2-RJ-E2 CNC:C-6882 EAP-W2-RJ-I2 CNC:C-6879...
  • Page 75 Certification 8.1 Approvals for SCALANCE W786 Notes on approval in Brazil SCALANCE W786 outdoor access point Operating Instructions, 06/2013, A5E02280428-08...
  • Page 76 Certification 8.1 Approvals for SCALANCE W786 Note The specified approvals apply only when the corresponding mark is printed on the product. SCALANCE W786 outdoor access point Operating Instructions, 06/2013, A5E02280428-08...
  • Page 77: National Approvals

    The diamond symbol (♦) identifies all countries for which there was no approval at the time these operating instructions were written. The current status of the approvals can be found on the Internet at the following address: Http://www.siemens.com/funkzulassungen Column Meaning...
  • Page 78 Certification 8.2 National approvals Country Mode (EIRP) Egypt 11b 11g 2412 100 mW Indoor + outdoor 11g Turbo 2472 5180 200 mW Indoor only 5240 5745 200 mW Indoor + outdoor 5825 5260 200 mW Indoor only DFS+TPC 5320 Angola 11b 11g 2412 100 mW Indoor + outdoor...
  • Page 79 Certification 8.2 National approvals Country Mode (EIRP) Australia 11b 11g 2412 100 mW Indoor + outdoor 11g Turbo 2472 5180 200 mW Indoor only 5320 5745 1000 mW Indoor + outdoor 5825 11a Turbo 5210 50 mW Indoor only 5250 200 mW Indoor only 5290 5760...
  • Page 80 Certification 8.2 National approvals Country Mode (EIRP) Chile 2412 100 mW Indoor only 2472 5180 100 mW Indoor only DFS+TPC 5320 5745 100 mW Indoor only 5825 11h Turbo 5210 100 mW Indoor only DFS+TPC 5250 100 mW Indoor only 5290 5760 100 mW Indoor only...
  • Page 81 Certification 8.2 National approvals Country Mode (EIRP) Belgium 11b 11g 2412 100 mW Indoor + outdoor Bulgaria 11g Turbo Denmark 2472 Germany 5180 200 mW Indoor only Estonia Finland 5240 France 5180 200 mW Indoor only Greece DFS+TPC Great Britain 5320 Ireland Iceland...
  • Page 82 Certification 8.2 National approvals Country Mode (EIRP) India 11b 11g 2412 100 mW Indoor + outdoor 2472 5180 200 mW Indoor only 5320 5745 200 mW Indoor only 5825 Japan 2412 100 mW Indoor + outdoor 2484 2412 100 mW Indoor + outdoor 2472 4920 200 mW Indoor + outdoor...
  • Page 83 Certification 8.2 National approvals Country Mode (EIRP) Colombia 11b 11g 2412 200 mW Indoor + outdoor 2417 1000 mW Indoor + outdoor 2457 2462 200 mW Indoor + outdoor 5180 200 mW Indoor only 5240 5745 1000 mW Indoor + outdoor 5825 11a Turbo 5760...
  • Page 84 Certification 8.2 National approvals Country Mode (EIRP) Macedonia 11b 11g 2412 100 mW Indoor + outdoor 11g Turbo 2472 5180 200 mW Indoor only 5240 5180 200 mW Indoor only DFS+TPC 5320 5500 1000 mW Indoor + outdoor 5580 5660 1000 mW Indoor + outdoor 5700 Mexico...
  • Page 85 Certification 8.2 National approvals Country Mode (EIRP) Peru 11b 11g 2412 200 mW Indoor + outdoor 11g Turbo 2417 1000 mW Indoor + outdoor 2457 2462 200 mW Indoor + outdoor 5180 200 mW Indoor only 5240 5745 1000 mW Indoor + outdoor 5825 Russia 11b 11g...
  • Page 86 Certification 8.2 National approvals Country Mode (EIRP) Singapore 11b 11g 2412 100 mW Indoor + outdoor 2472 5180 200 mW Indoor + outdoor 5240 5745 1000 mW Indoor + outdoor 5825 5260 200 mW Indoor + outdoor DFS+TPC 5320 11h Turbo 5210 100 mW Indoor + outdoor 5250...
  • Page 87 Certification 8.2 National approvals Country Mode (EIRP) Taiwan 11b 11g 1 2412 200 mW Indoor + outdoor 11g Turbo 2417 1000 mW Indoor + outdoor 2457 11 2462 200 mW Indoor + outdoor 5280 50 mW Indoor only 5320 5745 1000 mW Indoor + outdoor 5825 5500...
  • Page 88 Certification 8.2 National approvals Country Mode (EIRP) United Arab 11b 11g 2412 100 mW Indoor + outdoor Emirates 11g Turbo 2472 5180 200 mW Indoor only 5240 5180 200 mW Indoor only DFS+TPC 5320 5500 1000 mW Indoor only 5580 5660 1000 mW Indoor only 5700...
  • Page 89 Certification 8.2 National approvals Country Mode (EIRP) Vietnam 11b 11g 2412 100 mW Indoor + outdoor 11g Turbo 2472 5180 200 mW Indoor only 5240 5260 200 mW Indoor + outdoor DFS+TPC 5320 The following notice applies only to the SCALANCE W786-2HPW: Note Before commissioning the SCALANCE W786-2HPW, check that the Hipath Wireless Controller required for operation is also approved in the country of use.
  • Page 90 Certification 8.2 National approvals SCALANCE W786 outdoor access point Operating Instructions, 06/2013, A5E02280428-08...

This manual is also suitable for:

Scalance w786-2proScalance w786-3proScalance w786-2rr

Table of Contents