Prerequisites for Configuring SONET

Prerequisites for Configuring SONET
You must select the MediaType controller to configure and enter the controller configuration mode.
You must configure the controller as a SONET port.

Configuring MediaType Controller

To configure MediaType Controller, use the following commands:
enable
configure terminal
controller MediaType 0/5/0
mode sonet
end

Configuring SONET Ports

To configure SONET ports, use the following commands:
enable
configure terminal
controller MediaType 0/5/0
mode sonet
controller sonet 0/5/0
rate OC12
end
The above example shows how to configure SONET ports in OC-12 mode.

Managing and Monitoring SONET Line

This section describes how to manage and monitor SONET.

Configuring Line and Section Overhead

To configure line and section overhead, use the following commands:
enable
configure terminal
controller MediaType 0/5/0
mode sonet
controller sonet 0/5/0
overhead s1s0 2
overhead j0 tx length 1-byte
end
To restore the system to its default condition, use the no form of the command.
Note
1-Port OC-192 or 8-Port Low Rate CEM Interface Module Configuration Guide, Cisco IOS XE Everest 16.7.x
(Cisco ASR 900 Series)