Long-Reach EoVDSL Performance Characteristics
On No. 24 AWG Polyethylene Insulated Cable (PIC) twisted-pair wiring, the following performance is typical with
Long-Reach EoVDSL:
Distance (km)
0.50
1.00
1.50
2.00
2.50
3.20
4.00
4.60
5.00
EoVDSL Performance
Distance
0.9 km (2953 ft)
1.0 km (3280 ft)
1.3 km (4265 ft)
1.7 km (5577 ft)
2.0 km (6562 ft)
2.5 km (8202 ft)
Distance (ft)
1600
3300
4900
6600
8200
10500
13100
15100
16400
Downstream/Upstream (Mbps)
20
15
10
5
2.5
1.2
Downstream (Master
to Slave) (Mbps)
40
25
20
15
10
5
2.1
1.2
0.48
Chapter 3
Communication Ports
Upstream (Slave
to Master) (Mbps)
20
5
0.54
0.54
0.54
0.54
0.54
0.54
0.18
23