Introduction
Installing Device
Communication Ports
Technical Specifications
Dimension Drawings
Certification
1
2
3
4
5
6

Advertisement

Table of Contents
loading

Summary of Contents for Siemens RUGGEDCOM RS1600

  • Page 1 Preface Introduction Installing Device RUGGEDCOM RS1600 Communication Ports Technical Specifications Dimension Drawings Installation Guide Certification 6/2014 RC1013-EN-02...
  • Page 2: Security Information

    Warranty Siemens warrants this product for a period of five (5) years from the date of purchase, conditional upon the return to factory for maintenance during the warranty term. This product contains no user-serviceable parts. Attempted service by unauthorized personnel shall render all warranties null and void.
  • Page 3: Table Of Contents

    RUGGEDCOM RS1600 Installation Guide Table of Contents Table of Contents Preface ........................ Alerts ..............................v Related Documents ..........................v Accessing Documentation ........................v Training .............................. vi Customer Support ..........................vi Chapter 1 Introduction ......................1.1 Feature Highlights ........................1 1.2 Ports, Controls and Indicator LEDs ....................2 Chapter 2 Installing Device ....................
  • Page 4 RUGGEDCOM RS1600 Table of Contents Installation Guide 4.4 Fiber Optic Ethernet Port Specifications ..................18 4.4.1 10Base-FL/100Base-SX Ethernet Optical Specifications ............. 18 4.4.2 Fast Ethernet (100 Mbps) Optical Specifications ..............18 4.5 Operating Environment ....................... 19 4.6 Mechanical Specifications ......................19 Chapter 5 Dimension Drawings ..................
  • Page 5: Preface

    Installation Guide Preface Preface This guide describes the RUGGEDCOM RS1600. It describes the major features of the device, installation, commissioning and important technical specifications. It is intended for use by network technical support personnel who are responsible for the installation, commissioning and maintenance of the device.
  • Page 6: Training

    Siemens sales representative. Customer Support Customer support is available 24 hours, 7 days a week for all Siemens customers. For technical support or general information, please contact Siemens Customer Support through any of the following methods: • Online Visit http://www.siemens.com/automation/support-request...
  • Page 7: Introduction

    Installation Guide Introduction Introduction The RUGGEDCOM RS1600 provides substation hardened, fully managed, Ethernet switches specifically designed to operate reliably in electrically and environmentally harsh environments. The RS1600’s Zero-Packet-Loss™ technology provides a high level of immunity to electromagnetic interference (EMI) and heavy electrical surges typical of environments found in electric utility substations, industrial plant floors or in curb side traffic control cabinets.
  • Page 8: Ports, Controls And Indicator Leds

    Chapter 1 RUGGEDCOM RS1600 Introduction Installation Guide ▪ Exceeds NEMA TS-2 (traffic control equipment) • -40 to 85 °C (-40 to 185 °F) operating temperature (no fans) • Failsafe Output Relay: For critical failure or error alarming • Conformal coated printed circuit boards (optional) Cyber Security Features •...
  • Page 9 RUGGEDCOM RS1600 Chapter 1 Installation Guide Introduction PORT15 PORT16 RESET PORT12 PORT13 PORT14 POR T1 POR T2 POR T3 POR T4 POR T5 POR T6 POR T7 POR T8 POR T9 PORT10 PORT11 RUGGEDCOM RS1600 THISDEVICECOMPLIESWITH PART15OF FAILSAFE THEFCCRULES. OPERATION ISSUBJECTTO...
  • Page 10 RUGGEDCOM RS1600 Chapter 1 Installation Guide Introduction Ports, Controls and Indicator LEDs...
  • Page 11: Installing Device

    This product contains no user-serviceable parts. Attempted service by unauthorized personnel shall render all warranties null and void. Changes or modifications not expressly approved by Siemens Canada Ltd. could invalidate specifications, test results, and agency approvals, and void the user's authority to operate the equipment.
  • Page 12: Mounting The Device To A Rack

    Chapter 2 RUGGEDCOM RS1600 Installing Device Installation Guide The following sections describe the various methods of mounting the device: • Section 2.1.1, “Mounting the Device to a Rack” • Section 2.1.2, “Mounting the Device on a DIN Rail” • Section 2.1.3, “Mounting the Device to a Panel”...
  • Page 13: Mounting The Device On A Din Rail

    RUGGEDCOM RS1600 Chapter 2 Installation Guide Installing Device Section 2.1.2 Mounting the Device on a DIN Rail For DIN rail installations, the RS1600 can be equipped with panel/DIN rail adapters pre-installed on each side of the chassis. The adapters allow the device to be slid onto a standard 35 mm (1.4 in) DIN rail.
  • Page 14: Connecting Power

    Chapter 2 RUGGEDCOM RS1600 Installing Device Installation Guide Figure 4: Panel Mounting 1. Screw 2. Panel/DIN Rail Adapter Install the supplied screws to secure the adapters to the panel. Section 2.2 Connecting Power The RS1600 supports single or dual redundant high AC, high DC and/or low DC power supplies. The use of two power modules is recommended to provide redundancy and load balancing.
  • Page 15: Connecting Ac Power

    RUGGEDCOM RS1600 Chapter 2 Installation Guide Installing Device • Equipment must be installed according to applicable local wiring codes and standards. The following sections describe how to connect power to the device: • Section 2.2.1, “Connecting AC Power” • Section 2.2.2, “Connecting DC Power”...
  • Page 16: Connecting Dc Power

    Chapter 2 RUGGEDCOM RS1600 Installing Device Installation Guide Connect the ground terminal on the power source to the chassis ground terminal on the device. Section 2.2.2 Connecting DC Power To connect a high or low DC power supply to the device, do the following: CAUTION! Electrical hazard –...
  • Page 17 RUGGEDCOM RS1600 Chapter 2 Installation Guide Installing Device THISDEVICECOMPLIESWITH PART15OF FAILSAFE THEFCCRULES. OPERATION ISSUBJECTTO THEFOLLOWINGTWOCONDITIONS: (1) THIS RS232PORT DEVICEMAYNOTCAUSEHARMFUL INTERFERENCE, AND (2) THISDEVICEMUST ACCEPTANYINTERFERENCERECEIVED, INCLUDINGINTERFERENCETHATMAYCAUSE UNDESIRED OPERATION. POWERSUPPLY1 POWERSUPPLY2 Figure 7: Single AC Power Supply THISDEVICECOMPLIESWITH PART15OF FAILSAFE THEFCCRULES. OPERATION ISSUBJECTTO...
  • Page 18: Connecting The Failsafe Alarm Relay

    Chapter 2 RUGGEDCOM RS1600 Installing Device Installation Guide THISDEVICECOMPLIESWITH PART15OF FAILSAFE THEFCCRULES. OPERATION ISSUBJECTTO THEFOLLOWINGTWOCONDITIONS: (1) THIS RS232PORT DEVICEMAYNOTCAUSEHARMFUL INTERFERENCE, AND (2) THISDEVICEMUST ACCEPTANYINTERFERENCERECEIVED, INCLUDINGINTERFERENCETHATMAYCAUSE UNDESIRED OPERATION. POWERSUPPLY1 POWERSUPPLY2 Figure 10: Dual DC Power Supply THISDEVICECOMPLIESWITH PART15OF FAILSAFE THEFCCRULES. OPERATION ISSUBJECTTO...
  • Page 19: Connecting To The Device

    RUGGEDCOM RS1600 Chapter 2 Installation Guide Installing Device Figure 12: Failsafe Alarm Relay Wiring 1. Normally Closed Terminal 2. Common Terminal 3. Normally Open Terminal Section 2.4 Connecting to the Device The following describes the various methods for accessing the ROS console and Web interfaces on the device.
  • Page 20: Cabling Recommendations

    Section 2.5 Cabling Recommendations Siemens does not recommend the use of copper cabling of any length for critical, real-time substation automation applications. All copper Ethernet ports on RUGGEDCOM products include transient suppression circuitry to protect against damage from electrical transients and conform with IEC 61850-3 and IEEE 1613 Class 1 standards.
  • Page 21: Communication Ports

    RUGGEDCOM RS1600 Chapter 3 Installation Guide Communication Ports Communication Ports The RS1600 can be equipped with various types of communication ports to enhance its abilities and performance. To determine which ports are equipped on the device, refer to the factory data file available through ROS.
  • Page 22: Fiber Optic Ethernet Ports

    Chapter 3 RUGGEDCOM RS1600 Communication Ports Installation Guide The following is the pin-out for the RJ45 male connector: Name Description Receive Data+ Receive Data- Transmit Data+ Reserved (Do Not Connect) Figure 15: RJ45 Ethernet Port Pin Configuration Reserved (Do Not Connect)
  • Page 23: Technical Specifications

    RUGGEDCOM RS1600 Chapter 4 Installation Guide Technical Specifications Technical Specifications The following sections provide important technical specifications related to the device and available modules: • Section 4.1, “Power Supply Specifications” • Section 4.2, “Failsafe Relay Specifications” • Section 4.4, “Fiber Optic Ethernet Port Specifications”...
  • Page 24: Copper Ethernet Port Specifications

    Chapter 4 RUGGEDCOM RS1600 Technical Specifications Installation Guide Section 4.3 Copper Ethernet Port Specifications The following details the specifications for copper Ethernet ports that can be ordered with the RS1600. Speed Connector Duplex Cable Type Wiring Standard Maximum Distance Isolation...
  • Page 25: Operating Environment

    RUGGEDCOM RS1600 Chapter 4 Installation Guide Technical Specifications Section 4.5 Operating Environment Parameter Range Comments Ambient Operating Temperature -40 to 85 °C Measured from a 30 cm (12 in) radius surrounding the center of the (-40 to 185 °F) enclosure.
  • Page 26 RUGGEDCOM RS1600 Chapter 4 Installation Guide Technical Specifications Mechanical Specifications...
  • Page 27: Dimension Drawings

    RUGGEDCOM RS1600 Chapter 5 Installation Guide Dimension Drawings Dimension Drawings NOTE All dimensions are in millimeters, unless otherwise stated. 438.2 Figure 18: Overall Dimensions...
  • Page 28 Chapter 5 RUGGEDCOM RS1600 Dimension Drawings Installation Guide 464.6 479.4 Figure 19: Rack Mount Dimensions...
  • Page 29 RUGGEDCOM RS1600 Chapter 5 Installation Guide Dimension Drawings 486.4 476.3 Figure 20: Panel and DIN Rail Mount Dimensions...
  • Page 30 RUGGEDCOM RS1600 Chapter 5 Installation Guide Dimension Drawings...
  • Page 31: Certification

    RUGGEDCOM RS1600 Chapter 6 Installation Guide Certification Certification The RS1600 device has been thoroughly tested to guarantee its conformance with recognized standards and has received approval from recognized regulatory agencies. • Section 6.1, “Agency Approvals” • Section 6.2, “FCC Compliance”...
  • Page 32: Emi And Environmental Type Tests

    Chapter 6 RUGGEDCOM RS1600 Certification Installation Guide Section 6.4 EMI and Environmental Type Tests The RS1600 has passed the following EMI and environmental tests. IEC 61850-3 Type Tests Test Description Test Levels Severity Levels IEC 61000-4-2 Enclosure +/- 8 kV...
  • Page 33: Environmental Type Tests

    RUGGEDCOM RS1600 Chapter 6 Installation Guide Certification Test Description Test Levels Severity Levels IEC 60255-5 Dielectric Strength Signal ports 2 kVAC (Fail-Safe Relay output) DC Power ports 1.5 kVDC AC Power ports 2 kVDC HV Impulse Signal ports 5 kV (Fail-Safe Relay Output)
  • Page 34 Chapter 6 RUGGEDCOM RS1600 Certification Installation Guide Test Description Test Levels Severity Levels IEC 60068-2-30 Humidity (Damp Test Db 95% (non-condensing), Heat, Cyclic) 55 °C (131 °F), 6 cycles IEC 60255-21-1 Vibration 2 g @ 10-150 Hz Class 2 IEC 60255-21-2...