Cisco TelePresence ISDN Link
Contents
Introduction
xStatus SystemUnit Hardware MainBoard CPLDFirmware
Shows the version of installed CPLD firmware.
Value space of the result returned:
<String>
Example:
xStatus SystemUnit Hardware MainBoard CPLDFirmware
*s SystemUnit Hardware MainBoard CPLDFirmware: "s01770-6"
** end
xStatus SystemUnit Hardware MainBoard Temperature
Shows the temperature (in degrees Celsius) of the system's main board.
Value space of the result returned:
<String>
Example:
xStatus SystemUnit Hardware MainBoard Temperature
*s SystemUnit Hardware MainBoard Temperature: "33.5"
** end
xStatus SystemUnit State Status
Shows the system state, i.e. whether there are any errors or warnings issued.
Initializing: The system is initializing and not yet ready for use.
OK: The system is ready for use.
OKWithWarning: The system can be used for making calls, but there are warnings issued that might
influence its behavior.
Error: The system is in an erroneous state and cannot be used for making calls.
Value space of the result returned:
<Initializing/OK/OKWithWarning/Error>
Example:
xStatus SystemUnit State Status
*s SystemUnit State Status: Error
** end
D14953.01
ISDN Link API Reference Guide IL1.0 June 2012.
© 2012 Cisco Systems, Inc. All rights reserved.
About the API
xConfiguration
xStatus SystemUnit State StatusCode
xStatus SystemUnit State StatusText
xStatus SystemUnit State H320Number
65
xCommand
Shows the type of error or warning that is issued for the system (if any).
OK: The system is ready for use.
EthLinkDown: There is no Ethernet connection, and thus the ISDN Link cannot be used.
BRIWarning: A warning is issud for the BRI interface.
BRIError: There is an error on the BRI interface.
PRIError: There is an error on the PRI interface.
ExtNetError: There is an error on the external network interface (NET).
Initializing: The system is initializing and not yet ready for use.
Value space of the result returned:
<OK/EthLinkDown/BRIWarning/BRIError/PRIError/ExtNetError/Initializing>
Example:
xStatus SystemUnit State StatusCode
*s SystemUnit State StatusCode: BRIError
** end
Textual description of the system state, e.g. type of alarm if in an erroneous state.
Value space of the result returned:
<String>
Example:
xstatus SystemUnit State StatusText
*s SystemUnit State StatusText: "BRI1: [L1 Alarm] BRI2: [L1 Alarm] BRI3: [L1
Alarm] BRI4: [L1 Alarm]"
** end
Shows the number that can be used to dial in on the ISDN BRI/PRI interface in order to reach this
ISDN Link and subsequently the endpoint associated with the ISDN Link. This requires that numbers
have been assigned to the BRI or PRI interfaces respectively.
Not applicable when using the external network (NET) interface.
Value space of the result returned:
<String>
Example:
xStatus SystemUnit State H320Number
*s SystemUnit State H320Number: "5678"
** end