Installing the Router

Attaching a Chassis Ground Connection

Procedure
Step 1
Use the wire stripper to strip one end of the AWG #6 wire approximately 0.75 inches (19.05 mm).
Step 2
Insert the AWG #6 wire into the open end of the grounding lug.
Figure 31: Attaching a Grounding Lug to the Chassis Ground Connector
1
2
Step 3
Use the crimping tool to carefully crimp the wire receptacle around the wire. This step is required to ensure
a proper mechanical connection.
Step 4
Locate the chassis ground connector on the side of your chassis.
Step 5
Insert the two screws through the holes in the grounding lug.
The following figures show how to attach a grounding lug to the chassis ground connector.
Chassis ground lead wire
Grounding lug
Cisco ASR 1001-HX Router and Cisco ASR 1002-HX Router Hardware Installation Guide
Attaching a Chassis Ground Connection
3
Ground screws
4
Chassis ground connector holes
65