Mains connection and line-side power components
3.8 Line reactors
3.8.6
Technical data
3.8.6.1
Blocksize line reactors
Table 3- 17
Technical data of Blocksize line reactors PM240-2
Order No. 6SL3203-
Frame size
Matching Power
Modules
1)
Inductance
Unit rating of the Power
Module
Rated current
Power loss 50/60 Hz
Line/load connection
1L1, 1L2,1L3
2L1, 2L2, 2L3
PE connection
Degree of protection
Weight
x = A: Power Module with integrated line filter, x = U: Power Module without integrated line filter
1)
72
0CE13-2AA0
FSA
Line voltage 1-phase 200 VAC -10% to 240 VAC +10%:
6SL3210-
1PB13-0xL0
1PB13-8xL0
Line voltage 3-phase 380 VAC -10% to 480 VAC +10%:
6SL3210-
1PE11-8xL1
1PE12-3xL1
1PE13-2xL1
mH
2,5
kW
0,55 ... 1,1
A
4,0
W
23 / 25,3
Max. connectable
cross-section:
2.5 mm
2
Tightening torque:
0.6 ... 0.8 Nm
Type: M4 bolts
Tightening torque: 3
Nm
IP20
kg
1,1
0CE21-0AA0
0CE21-8AA0
FSA
FSB
6SL3210-
6SL3210-
1PB15-5xL0
1PB21-4xL0
1PB17-4xL0
1PB21-8xL0
1PB21-0xL0
6SL3211-
6SL3211-
1PB21-8xL0
1PB21-0xL0
6SL3210-
6SL3210-
1PE14-3xL1
1PE21-1xL0
1PE16-1xL1
1PE21-4xL0
1PE18-0xL1
1PE21-8xL0
6SL3211-
6SL3211-
1PE18-0xL1
1PE21-8xL0
1,0
0,5
1,5 ... 4,0
4,0 ... 7,5
11,3
22,3
36 / 39,6
53 / 58,3
Max. connectable
Max. connectable
cross-section:
cross-section: 6
2.5 mm
mm
2
Tightening torque:
Tightening torque:
0.6 ... 0.8 Nm
1.5 ... 1.8 Nm
Type: M4 bolts
Type: M5 bolts
Tightening torque: 3
Tightening torque: 5
Nm
Nm
IP20
IP20
2,1
2,95
Manual, (GH6), 04/2014, 6SL3097-4AL00-0BP4
0CE23-8AA0
FSC
6SL3210-
1PC22-2xL0
1PC22-8xL0
6SL3211-
1PC22-2xL0
6SL3210-
1PE22-7xL0
1PE23-3xL0
6SL3211-
1PE23-3xL0
0,3
11 ... 15
47,0
88 / 96,8
Max. connectable
cross-section: 16
mm
2
2
Tightening torque:
2.0 ... 4.0 Nm
Type: M5 bolts
Tightening torque: 5
Nm
IP20
2,95
AC Drive