No.
Parameter
000 MON/TEL DIAL 1 = Monitor
001 ALARM
STATUS
002 STOP COMM.
JRNL
003 CONTINUOUS
POLL
004 NUMERIC ID
SET
005 Not Used
006
ID DISPLAY
007
Not Used
008 MONITOR
009 DC LOOP
010 TX LEVEL
011 RX LEVEL
012 DTMF LEVEL
013 G3 RX EQL
014 G3 TX EQL
Function Parameter Table
Selections
2 = TEL/DIAL
1 = OFF
2 = Timer (6 sec.)
3 = Constant
1 = Off
2 = On
1 = Off
2 = Stn (Tx only)
1 = Off (will not accept)
2 = On (accepts)
1 = Number (Numeric ID)
2 = Chara (Character ID)
3 = Name (Station Name)
4 = Dial (Dialing Number)
1 = Off
2 = On
1 = Off (Normal)
2 = On (Off Hook)
00 = 0 dBm
~
15 = -15 dBm
1 = -43 dBm
2 = -38 dBm
3 = -33 dBm
4 = -48 dBm
00 = 0 dBm
~
15 = -15 dBm
1 = 0 dB
2 = 4 dB
3 = 8 dB
4 = 12 dB
1 = 0 dB
2 = 4 dB
3 = 8 dB
4 = 12 dB
Selects whether the machine starts to TX
automatically during On-Hook dialing.
Monitor
: Start to TX after pressing START
TEL/DIAL : Start to TX automatically
Selects the No Paper or No Toner alarm status.
OFF
: Alarm is disabled.
Timer
: Alarm will shut off after 6 seconds.
Constant : Alarm will not stop until "STOP" is
pressed or the error is cleared/corrected.
Selects whether the machine prompts to print the
COMM. Journal when the printout condition is set to
INC and STOP is pressed during communication.
Selects whether the Continuous Polling feature is
enabled.
Stn:
Place the document(s) on the ADF then press the
Program Key [P4] to store or add the document(s)
into a polled file. (See Note 4)
Selects whether the machine accepts and allows to
set or change the Numeric ID.
Selects the priority of displaying/Printing the ID,
Name or Dialing Number. (Default : 3 = Name)
1 = Number: Number>Name>Chara>Dial
2 = Chara : Chara>Name>Number>Dial
3 = Name : Name>Chara>Number>Dial
4 = Dial
: Dial>Name>Chara>Number
Selects whether the Monitor is ON/OFF for
monitoring fax signals.
(FOR SERVICE USE ONLY)
Selects a false Off Hook state for back to back
communication test.
Selects the TX signal output level, 0 to -15 dBm in 1
dBm steps. (Refer to Chapter 4.3.)
Selects the receiving sensitivity of -33/-38/-43/-48
dBm.
Selects the DTMF output level, 0 to -15 dBm in 1
dBm steps.
Selects the cable equalizer for G3 reception mode,
0dB, 4dB, 8dB or 12dB.
Selects the cable equalizer for G3 transmission
mode, 0dB, 4dB, 8dB or 12dB.