CHAPTER 6 FIXING SYSTEM
5) Disconnect the connector [3], and re-
move the snap-on assembly; then, de-
tach the internal delivery sensor [4].
4.7.3 Removing the Delivery Jam Sensor
1) Remove the fixing assembly from the
machine.
2) Remove the external delivery roller.
3) Remove the two screws [1], and detach
the sensor support plate [2].
4) Disconnect the connector [3], and de-
tach the delivery jam sensor [4].
6-40 P
COPYRIGHT © 2000 CANON INC.
[3]
F06-407-04
F06-407-05
[4]
F06-407-06
2000 2000 2000 2000
CANON iR5000/iR6000 REV.0 JULY 2000
[4]
[1]
[2]