Determining Primary Current - Canon iR5000 Service Manual

Hide thumbs Also See for iR5000:
Table of Contents

Advertisement

2.2 Determining Primary Current

To measure the dark area potential (VD) for the first time after the power switch is turned
on, the current used during previous measurement is let to flow, and the potential sensor is
used to measure the surface potential of the drum.
The DC controller PCB compares the surface potential of the drum against the target po-
tential; if the measured potential is ±6 V or higher than the target value, the primary current
is corrected, and the potential is measured once again. The potential is measured as many as
eight times, and the primary charging current is corrected as many as eight times.
Fixing assembly temperature195˚C
Potential sensor
Grid bias
Primary charging
COPYRIGHT © 2000 CANON INC.
Target
+6V
-6V
VD
WMUP
WMUPR
VD
VD
Vpc
Potential
control
sequence start
F04--202-01
2000 2000 2000 2000
CANON iR5000/iR6000 REV.0 JULY 2000
CHAPTER 4 IMAGE FORMATION SYSTEM
VD
VD
VD
Previous
potential
Target VD
VD
VD
VD
Vpc Vpc
Vpc
Correction
control
sequence start
200˚C
STBY
4-11 P