Page 2
Application This manual has been issued by Canon Inc. for qualified persons to learn technical theory, installation, maintenance, and repair of products. This manual covers all localities where the products are sold. For this reason, there may be information in this manual that does not apply to your locality.
Page 77
[Bit 3] Use it specify whether or not to transmit bit 33 and thereafter for the DIS signal. If ‘prohibit’ is selected, Super Fine reception from a non-Canon machine can no longer be used. [Bit 5] Use it to disable LT/LGL declaring as a remedy against a communication fault when the LTR/LGL cassette is used.
The 8 MB (as mounted) SDRAM used for the storage of image data is capable of storing about 58 pages of copies made of Canon Fax Standard Chart No. 1 (in sort mode) or about 80 pages in fax reception. The image data is backed up by a vanadium lithium secondary battery (BAT2), so that it remains intact for about 2 hr after the machine is deprived of power.
3) Evaluate all the information you have colleted, and take appropriate action based on comprehensive evaluation. If the other party is a non-Canon machine and no fault is found in the user’s machine, arrange for an investigation of the other party. Advise the user on REF.
CHAPTER 7 TROUBLESHOOTING • Troubleshooting a Communication Fault (Canon machine in use) Try a 3-station communication as indicated in the following diagram: Trouble FAX:A FAX:B FAX:C A: machine of the user Start B: machine of the other party C: test machine within the same block...
CHAPTER 7 TROUBLESHOOTING 4.5.3.11 Password A password used by a Canon facsimile machine may be any of the following: Password for Subaddress Communications: This is an ID number used for a subaddress communication and, as in the case of a subaddress, it consists of 20 or fewer characters (numerals, *, #, space).
Page 315
CRP was received, exceeding the permitted number of trans- missions of the procedure signal Cause: The procedure signal is faulty. Remedy: Record the protocol on a DAT or MD, and have it analyzed by the local Canon office and/or Technical Center. ##111 [TX/RX] Memory error Cause: While printing data stored in the image memory, the effects of noise caused a data error.
Page 317
Cause: The procedure signal is faulty. Remedy: Record the protocol on a DAT or MD, and have it analyzed by the local Canon office and/or Technical Center. ##229 [RX] The recording system became locked for 1 min Cause: Not identified.
Page 320
Cause: The procedure signal has a fault. Remedy: Record the protocol on a DAT or MD, and have it analyzed by the local Canon office and/or Technical Center. ##289 [TX] After transmitting EOM, a signal other than PIN, PIP, MCF, RTP,...
Page 321
1. Start G3 mode, and transmit once again (Prohibit the ECM mode). 2. Decrease the transmission start speed. 3. Record the protocol on a DAT or MD, and have it analyzed by the local Canon office and/or Technical Center. ##754 [TX]...
Page 322
1. Start G3 mode, and transmit once again (Prohibit the ECM mode). 2. Decrease the transmission start speed. 3. Record the protocol on a DAT or MD, and have it analyzed by the local Canon office and/or Technical Center. ##759 [TX]...
Page 325
1. Start G3 mode, and transmit once again (Prohibit the ECM mode). 2. Decrease the transmission start speed. 3. Record the protocol on a DAT or MD, and have it analyzed by the local Canon office and/or Technical Center. ##769 [TX]...
Page 326
1. Start G3 mode, and transmit once again (Prohibit the ECM mode). 2. Decrease the transmission start speed. 3. Record the protocol on a DAT or MD, and have it analyzed by the local Canon office and/or Technical Center. ##774 [TX]...
Page 329
1. Start G3 mode, and transmit once again (Prohibit the ECM mode). 2. Decrease the transmission start speed. 3. Record the protocol on a DAT or MD, and have it analyzed by the local Canon office and/or Technical Center. ##784 [TX]...
Page 330
1. Start G3 mode, and transmit once again (Prohibit the ECM mode). 2. Decrease the transmission start speed. 3. Record the protocol on a DAT or MD, and have it analyzed by the local Canon office and/or Technical Center. ##789 [TX]...
Page 331
Cause: The procedure signal is faulty. Remedy: Record the protocol on a DAT or MD, and have it analyzed by the local Canon office and/or Technical Center. ##792 [RX] In ECM reception, PPS-NULL between partial pages cannot be...