Sign In
Upload
Manuals
Brands
Siemens Manuals
Controller
RVP360
Siemens RVP360 Manuals
Manuals and User Guides for Siemens RVP360. We have
1
Siemens RVP360 manual available for free PDF download: Basic Documentation
Siemens RVP360 Basic Documentation (106 pages)
Heating controller for 2 heating circuits and d.h.w.
Brand:
Siemens
| Category:
Controller
| Size: 1.9 MB
Table of Contents
Table of Contents
3
1 Summary
9
Brief Description and Key Features
9
Type Summary
9
Equipment Combinations
9
Suitable Sensors
9
Suitable Room Units
10
Suitable Actuators
10
Communication
10
Documentation
10
2 Use
11
Types of Plant
11
Types of Houses and Buildings
11
Types of Heating Systems
11
Heating Circuit Functions
11
Functions
12
3 Basics
13
Key Technical Features
13
Plant Types
13
Plant Types with Regard to Heating Circuit
13
Plant Types with Regard to D.h.w
14
Selectable Combinations
14
Setting Levels, Function Blocks, and Plant Types
16
Heating Circuit Operating Modes
16
Heating Modes
17
Manual Control
17
Plant Type and Operating Mode
18
Operating State and Operating Level
18
4 Acquisition of Measured Values
19
Room Temperature (A6, B5 / A6, B52)
19
Types of Sensors
19
Error Handling
19
Room Model
20
Flow Temperature (B1, B12)
20
Types of Sensors
20
Error Handling
20
Boiler Temperature (B2)
20
Outside Temperature (B9)
20
Error Handling
21
Return Temperature (B7)
21
Types of Sensors
21
Storage Tank Temperature (B31, B32)
21
Error Handling
22
Collector Temperature (B6)
23
Type of Sensor
23
Error Handling
23
5 Function Block: End-User Space Heating
24
Operating Lines
24
Setpoints
24
General
24
Frost Protection for the Building
24
Heating Program
25
Holiday Program
25
Heating Curve
25
6 Function Block: End-User D.h.w
26
Operating Lines
26
Setpoints
26
NORMAL D.h.w. Temperature Setpoint
26
REDUCED D.h.w. Temperature Setpoint
26
Actual Value
27
7 Function Block: End-User General
28
Operating Lines
28
Scheduler Program 2
28
Time of Day and Date
28
Faults
29
8 Function Block: Plant Configuration
30
Operating Line
30
General
30
9 Function Block: Space Heating
31
Operating Lines
31
Automatic ECO Function
31
Compensating and Auxiliary Variables
31
Heating Limits
32
Mode of Operation
33
Room Temperature Source
33
Optimization
34
Definition and Purpose
34
Basics
34
Optimization with Room Sensor
34
Optimization Without Room Sensor
34
Process
35
Room Model Temperature
35
Optimized Switching off
36
Quick Setback
36
Optimized Switching on
37
Boost Heating
37
Room Functions
38
Maximum Limitation of Room Temperature
38
Room Influence
39
Heating Curve
40
Purpose
40
Settings
40
Deflection
41
Parallel Displacement of Heating Curve
41
Generation of Setpoint
42
10 Function Block: Pump Heating Circuit
43
Operating Line
43
Protection against Overtemperatures
43
11 Function Block: Actuator Heating Circuit
44
Operating Lines
44
Limitations
44
Flow Temperature Limitations
44
Setpoint Increase
45
Type of Actuator
46
2-Position Control
46
Auxiliary Variables in Interconnected Plants
47
Temperature Boost Mixing Valve
47
Pulse Lock with 3-Position Actuator
47
12 Function Block: Boiler
48
Operating Lines
48
Operating Mode
48
Limitations
49
Maximum Limitation of Boiler Temperature
49
Minimum Limitation of Boiler Temperature
49
Actions During D.h.w. Heating
49
2-Position Control
50
Control with 1-Stage Burner
50
Control with 2-Stage Burner
51
Frost Protection for the Boiler
52
Protective Boiler Startup
52
Protection against Boiler Overtemperatures
53
Operating Mode of Pump M1
54
13 Function Block: Setpoint Return Temperature Limitation
55
Operating Line
55
Description
55
Minimum Limitation of Return Temperature
55
Type of Sensor
55
Mode of Operation
55
Mode of Operation with an Autonomous Unit (Without Bus)
56
Mode of Operation in Interconnected Plants
56
14 Function Block: D.h.w
57
Operating Lines
57
Assignment of D.h.w
57
Program for the Circulating Pump
57
Frost Protection for D.h.w
57
Release of D.h.w. Heating
58
Function
58
Release Programs
58
Heating During Holiday Periods
59
Priority and Flow Temperature Setpoint
59
Settings
59
Priority
60
Absolute Priority
60
Shifting Priority
60
No Priority
61
Flow Temperature Setpoint
61
Maximum Selection
61
Type of D.h.w. Charging
61
Storage Tank Sensor/Thermostat
61
Boost of D.h.w. Charging Temperature
63
Maximum D.h.w. Charging Time
63
Setpoint Legionella Function
64
Forced Charging
64
Protection against Discharging
64
Purpose
64
Mode of Operation
64
Manual D.h.w. Charging
65
15 Function Block: Multifunctional Relay
66
Operating Line
66
Functions
66
No Function
66
Relay Energized in the Event of Fault
67
Relay Energized When There Is Demand for Heat
67
Circulating Pump
67
Collector Pump
68
Type of D.h.w. Charging
69
16 Function Block: Legionella Function
70
Operating Lines
70
Setpoint/Switching On/Off
70
Periodicity of Legionella Function
70
Starting Point
70
Dwelling Time at Legionella Setpoint
70
Operation of Circulating Pump
71
Mode of Operation
71
17 Function Block: Service Functions and General Settings
73
Operating Lines
73
Display Functions
73
Hours Run Counter
73
Software Version
73
Commissioning Aids
74
Simulation of Outside Temperature
74
Relay Test
74
Sensor Test
75
Auxiliary Functions
76
Frost Protection for the Plant
76
Pump Overrun
76
Pump Kick
77
Winter-/Summertime Changeover
77
Locking Signal Gain
77
Inputs for LPB
79
Source of Time of Day
79
Outside Temperature Source
80
Addressing the Devices
80
Bus Power Supply
81
Bus Loading Number
81
18 Function Block: Solar D.h.w
82
Operating Lines
82
General
82
Functions
83
Temperature Differential ON/OFF Solar
83
Minimum Charging Temperature
83
Minimum Running Time
84
Fost Protection Temperature for the Collector
84
Overtemperature Protection for the Collector
85
Storage Tank Recooling
86
Evaporation Temperature of Heat Conducting Medium
87
Maximum Limitation of Charging Temperature
87
Maximum Limitation of Storage Tank Temperature
88
Collector Start Function
88
19 Function Block: Locking Functions
89
Operating Line
89
Locking Settings on the Software Side
89
20 Communication
90
Interplay with Room Units
90
General
90
Interplay with Room Unit QAA50.110/101
90
Interplay with Room Unit QAW70
91
Interplay with SYNERGYR Central Unit OZW30
93
Communication with Other Devices
93
21 Handling
94
Operation
94
General
94
Operating Elements
95
Setting Levels and Access Rights
97
Commissioning
97
Installation Instructions
97
Operating Lines
97
Installation
98
Mounting Location
98
Mounting Choices
98
Electrical Installation
98
22 Engineering
99
Connection Terminals
99
Connection Diagrams
100
Low-Voltage Side
100
Mains Voltage Side
100
23 Mechanical Design
101
Basic Design
101
Dimensions
101
24 Addendum
102
Technical Data
102
Revision History
102
Advertisement
Advertisement
Related Products
Siemens RVP36
Siemens RVP550
Siemens RVP540
Siemens RVP201.0
Siemens RVP211.0
Siemens RVP201
Siemens RVP211
Siemens RVP200
Siemens RVP210
Siemens RVA47.320
Siemens Categories
Industrial Equipment
Controller
Control Unit
Oven
Washer
More Siemens Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL