Sign In
Upload
Manuals
Brands
Panasonic Manuals
Heat Pump
WH-UD09FE8
Panasonic WH-UD09FE8 Heat Pump Split Manuals
Manuals and User Guides for Panasonic WH-UD09FE8 Heat Pump Split. We have
5
Panasonic WH-UD09FE8 Heat Pump Split manuals available for free PDF download: Service Manual, Design Handbook, Operating Instructions Manual
Panasonic WH-UD09FE8 Service Manual (205 pages)
Brand:
Panasonic
| Category:
Air Conditioner
| Size: 8.53 MB
Table of Contents
Outdoor Unit
1
Table of Contents
2
1 Safety Precautions
4
2 Specifications
6
Wh-Adc0916G9E8 Wh-Ux09Fe8
6
Wh-Adc0916G9E8 Wh-Ux12Fe8
9
Wh-Adc0916G9E8 Wh-Ux16Fe8
12
Wh-Adc0916G9E8 Wh-Ud09Fe8
15
Wh-Adc0916G9E8 Wh-Ud12Fe8
18
Wh-Adc0916G9E8 Wh-Ud16Fe8
21
3 Features
24
4 Location of Controls and Components
25
Indoor Unit
25
Weekly Timer Setting
31
Main Components
33
Outdoor Unit
34
5 Dimensions
35
Indoor Unit
35
Outdoor Unit
36
6 Refrigeration and Water Cycle Diagram
37
7 Block Diagram
38
Wh-Adc0916G9E8 Wh-Ux09Fe8 Wh-Adc0916G9E8 Wh-Ux12Fe8 Wh-Adc0916G9E8 Wh-Ux16Fe8
38
Wh-Adc0916G9E8 Wh-Ud09Fe8 Wh-Adc0916G9E8 Wh-Ud12Fe8 Wh-Adc0916G9E8 Wh-Ud16Fe8
39
8 Wiring Connection Diagram
40
Indoor Unit
40
Outdoor Unit
41
9 Electronic Circuit Diagram
44
Indoor Unit
44
Outdoor Unit
45
10 Printed Circuit Board
48
Indoor Unit
48
Outdoor Unit
49
Noise Filter Printed Circuit Board
52
11 Installation Instruction
53
Indoor Unit
53
Piping Installation
54
Refrigerant Piping Installation
54
Outdoor Unit
60
Connecting the Piping
61
Evacuation of the Equipment
62
Connect the Cable to the Outdoor Unit
63
Pipe Insulation
63
12 Operation and Control
64
Basic Function
64
Cooling Operation
66
Thermostat Control
66
Cool Mode Operation
66
Auto Mode Operation
67
Way Valve Control
71
Water Pump
75
Pump down Operation [Service Mode: 01]
77
Flow Switch
77
Indoor Unit Safety
78
Auto Restart Control
78
Indication Panel
78
Indoor Back-Up Heater Control
79
Heater Control for Tank Side
80
Base Pan Heater Control (Optional)
80
Tank Pre-Thermo off Control
81
Sterilization Mode
81
Heating Outdoor Ambient Thermo off Control
82
Quiet Operation
82
Anti Freeze Control
82
External Room Thermostat Control (Optional)
83
Three Ways Valve Control
84
Two Ways Valve Control
85
External OFF/ON Control
85
Holiday Mode
86
Dry Concrete Function
86
13 Protection Control (UX09FE8, UX12FE8 and UX16FE8)
87
Protection Control for All Operations
87
Protection Control for Heating Operation
89
Protection Control for Cooling Operation
91
Heat Exchanger (HEX) Protection Control
91
14 Protection Control (UD09FE8, UD12FE8 and UD16FE8)
92
Protection Control for All Operations
92
Protection Control for Heating Operation
94
Protection Control for Cooling Operation
96
Heat Exchanger (HEX) Protection Control
96
15 Servicing Guide
97
Open and Close Top Front Plate
97
How to Take out Bottom Front Plate
97
Test Run
97
Proper Pump down Procedure
98
Adjust Water Flow Rate with Water Pump
98
Expansion Vessel Pre Pressure Checking
99
How to Unlock Cool Mode
99
Dry Concrete [SERVICE MODE: 03]
99
EEPROM Factory Default Data Setup Procedure
99
16 Maintenance Guide
101
17 Troubleshooting Guide
104
Refrigeration Cycle System
104
Relationship between the Condition of the Air-To-Water Hydromodule + Tank and Air-To-Water Heatpump Outdoor Units and Pressure and Electric Current
105
Breakdown Self Diagnosis Function
106
Error Codes Table
107
Self-Diagnosis Method
109
Troubleshooting
110
18 Disassembly and Assembly Instructions
146
To Remove Top Plate
146
To Remove Pressure Gauge and Control Panel
147
To Remove Bottom Front Plate
147
To Remove RCCB
148
To Remove Transformer and Electronic Controller
148
To Remove Pressure Relief Valve, Flow Switch and Air Purge Valve
149
To Remove Water Pump
149
To Remove Bottle Complete
150
To Remove Anode Bar
150
To Remove Water Filter
151
19 Technical Data
152
Operation Characteristics
152
Heating Capacity Table
183
Cooling Capacity Table
185
20 Exploded View and Replacement Parts List
187
Indoor Unit
187
Outdoor Unit
191
Advertisement
Panasonic WH-UD09FE8 Design Handbook (132 pages)
Brand:
Panasonic
| Category:
Heat Pump
| Size: 29.03 MB
Table of Contents
Table of Contents
6
Introduction
8
Operating Principles of the Air / Water Heat Pump
8
Coefficient of Performance and Performance Factor
9
Economical and Environmentally Friendly
10
Heat Pump System
12
Heat Source
12
Heat Pump
13
Function and Properties
13
Operating Mode
13
Heat Utilisation
14
Heating
14
Water Heating
15
Cooling
16
Systematics and Overview
17
Systematics
17
Hydromodule
17
Outdoor Unit
18
Monobloc Unit
18
Overview
19
Series
20
Bi-Bloc and Monobloc System
21
Products, Functions and Technical Data
22
Bi-Bloc System
22
Product Features
22
Hydromodule
24
Outdoor Unit
27
Dimensional Drawing
28
Technical Data
30
Monobloc System
38
Monobloc Unit
40
Technical Data
42
Accessories
44
Hot Water Tank
44
Extras
53
Closed-Loop Control
54
Design
54
Functions
54
Basic Functions
54
Further Functions
57
Safety Functions
58
Extensions and External Interfaces
58
External Room Thermostat
58
Deactivation of Heating Circuits in Cooling Mode
59
External Control of the Aquarea Heat Pump
59
External Solar Thermal Installation
60
Aquarea Heat Pump Manager
61
Smart Grid" Function Via the Heat Pump Manager
63
Project Design
66
Design Steps
66
Panasonic Aquarea Designer
66
Establishing the Heating Load and Outside Design Temperature
67
Sizing the Hot Water Cylinder
69
Establishing the Heat Emitter Temperatures
71
Operating Mode and Bivalence Point
72
Heat Pump Selection
73
General Criteria
73
What Capacity Is Needed
73
Planning of Installation Room
76
Room Volume for Bi-Bloc System
77
Assembly Conditions and Minimum Distances from Hydromodule
77
Planning Heat Source - Air
79
Bi-Bloc System
79
Capacity Decrease in Long Refrigerant Pipe Runs
80
Assembly Conditions and Minimum Distances Around Outdoor Unit
80
Fastening of the Outdoor Unit
81
Monobloc System
82
Assembly Conditions and Minimum Distances from Monobloc Unit
83
Fastening of the Monobloc Unit
84
Acoustics
85
Sound Pressure Level
85
Sound Power Levels for Estimation of Sound Pressure Level
86
Cooling
89
Cooling with Underfloor Heating
89
Cooling with Fan Convectors
89
Electrical Connection
90
Power Supply
90
Connections to the Inputs and Outputs
93
DNO and Tariffs
94
Hydraulics
94
Hydraulic Integration
94
Hydraulic Decoupling for Standard Pumps and High-Efficiency Pumps
95
Without Differential Pressure Control
95
Hydraulic Decoupling for High-Efficiency Pumps with Differential Pressure Control
95
Inline/Strainer Filter
96
Magnetic Particle Filter
96
System Volume
96
Pumping Height and Pipe Network Resistance
97
Pumping Height
99
Hydraulic Balancing
101
Special Behaviour When Cooling
101
Expansion Vessel
102
Heating Water Quality
103
Use of Buffer Tanks
103
Examples
104
Examples Legend
104
Examples 1 to 10
105
Appendix
115
Panasonic WH-UD09FE8 Operating Instructions Manual (100 pages)
Air-to-Water Hydromodule + Tank
Brand:
Panasonic
| Category:
Heat Pump
| Size: 4.29 MB
Table of Contents
English
2
Operating Instructions
1
Table of Contents
2
Safety Precautions
3
To Adjust Initial Settings
6
How to Use
8
Holiday Mode
10
Weekly Timer Setting
11
Cleaning Instructions
12
Troubleshooting
13
Troubleshooting
14
Information
15
Français
16
Consignes de Sécurité
17
Réglage Initial
20
Consignes D'utilisation
22
Instructions de Nettoyage
26
Dépannage
27
Informations
29
Español
30
Precauciones de Seguridad
31
Ajuste de la Configuración Inicial
34
Forma de Uso
36
Instrucciones de Lavado
40
Localización de Averías
41
Información
43
Deutsch
44
Sicherheitshinweise
45
System-Grundeinstellungen
48
Bedienung
50
Reinigungsanweisungen
54
Störungssuche
55
Informationen
57
Advertisement
Panasonic WH-UD09FE8 Service Manual (65 pages)
Air-to-Water Hydromodule + Tank
Brand:
Panasonic
| Category:
Heat Pump
| Size: 0.8 MB
Table of Contents
Condition (Ambient/Water)
4
Cooling
4
Heating
4
Table of Contents
5
A7W35 A2W35
5
Indoor Unit
6
Cooling
7
Heating: -20
7
Cooling
8
A7W35 A2W35
10
Heating
10
DC Motor
11
Brazed Plate
11
Software Selection)
11
Cooling: 20.1 (1.2)
11
Heating: 25.8 (1.5)
11
Open: 300, Close: 265 and below
11
Magnetic Lead Switch
11
Open: 1150±200, Close: 700 and below
11
Residual Current Circuit Breaker
12
Panasonic WH-UD09FE8 Service Manual (24 pages)
Air-to-Water Heatpump
Brand:
Panasonic
| Category:
Heat Pump
| Size: 1.01 MB
Table of Contents
Safety Precautions
2
Main Components
9
Outdoor Unit
9
Indoor Unit
10
Refrigeration and Water Cycle Diagram
12
How to Adjust Water Flow Rate [SERVICE MODE: 02]
15
Expansion Vessel Pre Pressure Checking
15
How to Unlock Cool Mode
15
Heating Capacity Table
22
Cooling Capacity Table
23
Advertisement
Related Products
Panasonic WH-UD09FE5
PANASONIC WH-UD09CE8
PANASONIC WH-UD09CE5-A
PANASONIC WH-UD09CE8-1
PANASONIC WH-UD09CN8-1
PANASONIC WH-UD09CN8
Panasonic WH-UD09CE5
Panasonic WH-UD09HE5
Panasonic WH-UD09HE5-1
Panasonic WH-UD09HE8
Panasonic Categories
Camcorder
Air Conditioner
TV
Digital Camera
Cordless Telephone
More Panasonic Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL