Sign In
Upload
Manuals
Brands
GE Manuals
Controller
C60
User Manuals: GE C60 Breaker Protection System
Manuals and User Guides for GE C60 Breaker Protection System. We have
7
GE C60 Breaker Protection System manuals available for free PDF download: Instruction Manual, Communications Manual
GE C60 Instruction Manual (682 pages)
Breaker Protection System UR Series
Brand:
GE
| Category:
Protection Device
| Size: 11.59 MB
Table of Contents
Table of Contents
3
1 Getting Started
11
Important Procedures
11
Cautions and Warnings
11
Inspection Procedure
12
Ur Overview
13
Introduction to the Ur
13
Hardware Architecture
13
Software Architecture
14
Enervista Ur Setup Software
15
System Requirements
15
Installation
15
Configuring the C60 for Software Access
16
Using the Quick Connect Feature
19
Connecting to the C60 Relay
24
Setting up Cybersentry and Changing Default Password
25
Ur Hardware
26
Mounting and Wiring
26
Communications
26
Faceplate Display
26
Using the Relay
27
Faceplate Keypad
27
Menu Navigation
27
Menu Hierarchy
27
Relay Activation
28
Relay Passwords
28
Flexlogic Customization
28
Commissioning
29
2 Product Description
31
Introduction
31
Overview
31
Security
32
Iec 870-5-103 Protocol
37
Order Codes
39
Overview
39
Order Codes with Enhanced Ct/Vt Modules
39
Order Codes with Process Bus Modules
42
Replacement Modules
44
Signal Processing
47
Ur Signal Processing
47
Specifications
49
Protection Elements
49
User-Programmable Elements
51
Monitoring
52
Metering
52
Inputs
53
Power Supply
54
Outputs
54
Communication Protocols
56
Inter-Relay Communications
56
Environmental
58
Type Tests
59
Production Tests
59
Approvals
60
Maintenance
60
3 Hardware
61
Description
61
Panel Cutout
61
Rear Terminal Layout
67
Wiring
69
Typical Wiring
69
Dielectric Strength
70
Control Power
70
Ct/Vt Modules
71
Process Bus Modules
73
Contact Inputs and Outputs
73
Transducer Inputs/Outputs
86
Rs232 Faceplate Port
87
Cpu Communication Ports
88
Irig-B
90
Direct Input/Output Communications
91
Description
91
Fiber: Led and Eled Transmitters
93
Fiber-Laser Transmitters
93
Interface
95
Rs422 Interface
98
Rs422 and Fiber Interface
100
And Fiber Interface
100
Ieee C37.94 Interface
101
C37.94Sm Interface
105
4 Human Interfaces
109
Enervista Ur Setup Interface
109
Introduction
109
Creating a Site List
109
Enervista Ur Setup Overview
109
Enervista Ur Setup Main Window
111
Extended Enervista Ur Setup Features
112
Settings Templates
112
Securing and Locking Flexlogic Equations
116
Settings File Traceability
118
Faceplate Interface
121
Faceplate
121
Led Indicators
122
Custom Labeling of Leds
125
Display
130
Keypad
130
Breaker Control
130
Menus
131
Changing Settings
134
5 Settings
135
Overview
137
Settings Menu
137
Flex State Parameters
137
User-Definable Displays
137
Teleprotection
137
Introduction to Elements
140
Introduction to Ac Sources
141
Product Setup
144
Security
154
Display Properties
160
Clear Relay Records
161
Communications
163
Modbus User Map
201
Real Time Clock
201
Fault Reports
206
Oscillography
208
Data Logger
210
Demand
212
User-Programmable Leds
213
User-Programmable Self Tests
216
Control Pushbuttons
218
Direct Inputs and Outputs
227
Installation
236
Remote Resources Configuration
237
System Setup
240
Power System
240
Signal Sources
241
Breakers
244
Disconnect Switches
248
Flexcurves
251
Phasor Measurement Unit
258
Flexlogic
282
Introduction to Flexlogic
282
Flexlogic Rules
291
Flexlogic Evaluation
292
Flexlogic Example
292
Flexlogic Equation Editor
297
Flexlogic Timers
297
Flexelements
298
Non-Volatile Latches
302
Grouped Elements
304
Overview
304
Setting Group
304
Phase Current
305
Neutral Current
314
Ground Current
317
Breaker Failure (Ansi 50Bf)
320
Voltage Elements
329
Supervising Elements
336
Sensitive Directional Power (Ansi 32)
338
Control Elements
341
Overview
341
Trip Bus
341
Setting Groups
343
Selector Switch
345
User-Programmable Pushbuttons
350
Synchrocheck
351
Autoreclose (Ansi 79)
356
Digital Elements
369
Digital Counters
372
Monitoring Elements
374
Inputs and Outputs
390
Contact Inputs
390
Virtual Inputs
392
Contact Outputs
393
Virtual Outputs
396
Remote Devices
396
Remote Inputs
398
Remote Double-Point Status Inputs
399
Remote Outputs
399
Resetting
400
Direct Inputs and Outputs
401
Teleprotection Inputs and Outputs
405
Iec 61850 Goose Analogs
407
Iec 61850 Goose Integers
408
Transducer Inputs and Outputs
410
Test Mode
415
Force Contact Inputs
416
Force Contact Outputs
417
Phasor Measurement Unit Test Values
418
Actual Values Menu
421
Dcma Inputs
422
Rtd Inputs
422
Contact Inputs
424
Virtual Inputs
424
Remote Inputs
424
Remote Double-Point Status Inputs
425
Teleprotection Inputs
425
Contact Outputs
425
Virtual Outputs
426
Autoreclose
426
Remote Devices
426
Digital Counters
427
Selector Switches
427
Flex States
428
Ethernet
428
Real Time Clock Synchronizing
428
Direct Inputs
429
Direct Devices Status
430
Iec 61850 Goose Integers
430
Egd Protocol Status
430
Teleprotection Channel Tests
431
Remaining Connection Status
431
Parallel Redundancy Protocol (Prp)
432
Metering Conventions
433
Sources
436
Synchrocheck
441
Tracking Frequency
441
Flexelements
441
Iec 61580 Goose Analog Values
442
Sensitive Directional Power
442
Phasor Measurement Unit
443
Pmu Aggregator
443
Transducer Inputs/Outputs
444
Records
445
Fault Reports
445
Event Records
445
Oscillography
446
Data Logger
446
Phasor Measurement Unit Records
447
Breaker Maintenance
447
Product Information
448
Model Information
448
Firmware Revisions
448
Advertisement
GE C60 Instruction Manual (680 pages)
Breaker Protection System
Brand:
GE
| Category:
Relays
| Size: 26.31 MB
Table of Contents
Table of Contents
3
1 Introduction
11
Safety Symbols and Definitions
11
General Cautions and Warnings
11
For Further Assistance
12
2 Product Description
15
Description
16
Security
17
Order Codes
21
Order Codes with Enhanced CT/VT Modules
22
Order Codes with Process Bus Modules
25
Replacement Modules
29
Signal Processing
31
UR Signal Processing
31
Specifications
33
Protection Elements
34
User-Programmable Elements
37
Monitoring
39
Metering
40
Inputs
40
Power Supply
42
Outputs
43
Communication Protocols
45
Inter-Relay Communications
46
Cybersentry Security
47
Graphical Front Panel
47
Environmental
48
Type Tests
49
Production Tests
49
Approvals
50
Maintenance
50
3 Installation
51
Unpack and Inspect
51
Panel Cutouts
52
Horizontal Units
52
Vertical Units
56
Rear Terminal Layout
61
Wiring
64
Typical Wiring
64
Dielectric Strength
65
Control Power
65
CT/VT Modules
66
Process Bus Modules
68
Contact Inputs and Outputs
68
Transducer Inputs and Outputs
80
RS232 Port
82
CPU Communication Ports
83
Irig-B
85
Direct Input and Output Communications
86
Description
86
Fiber: LED and ELED Transmitters
88
Fiber Laser Transmitters
88
Interface
89
RS422 Interface
93
RS422 and Fiber Interface
95
And Fiber Interface
96
IEEE C37.94 Interface
96
C37.94SM Interface
99
Activate Relay
102
Install Software
103
Enervista Communication Overview
103
System Requirements
104
Install Software
105
Add Device to Software
106
Set IP Address in UR
107
Configure Serial Connection
112
Configure Ethernet Connection
114
Configure Modem Connection
115
Automatic Discovery of UR Devices
115
Connect to the C60
116
Connect to the C60 in Enervista
116
Use Quick Connect Via Front RS232 Port
117
Use Quick Connect Via Front USB Port
118
Use Quick Connect Via a Rear Ethernet Port
118
Set up Cybersentry and Change Default Password
119
Import Settings
120
Connect to D400 Gateway
121
Oscillography Files
121
Event Records
121
Log Files
121
Setting Files
122
4 Interfaces
123
Enervista Software Interface
123
Introduction
123
Settings Files
123
Event Viewing
124
File Support
125
Enervista Main Window
125
Protection Summary Window
126
Settings Templates
127
Secure and Lock Flexlogic Equations
131
Settings File Traceability
134
Front Panel Interface
137
Front Panel
137
Front Panel Display
139
Front Panel Navigation Keys
159
LED Indicators
160
Front Panel Labelling
165
Menu Navigation
172
Change Settings
174
View Actual Values
179
Breaker Control
180
Change Passwords
181
Invalid Password Entry
182
Logic Diagrams
183
Flexlogic Design Using Engineer
184
Design Logic
186
Send File to and from Device
196
Monitor Logic
197
View Front Panel and Print Labels
198
Generate Connectivity Report
199
Preferences
199
Toolbars
203
5 Settings
209
Settings Menu
209
Overview
212
Introduction to Elements
212
Introduction to AC Sources
214
Product Setup
215
Security
215
Display Properties
234
Graphical Front Panel
236
Clear Relay Records
248
Communications
249
Modbus User Map
316
Real Time Clock
317
Fault Reports
321
Oscillography
323
Data Logger
325
Demand
327
User-Programmable Leds
331
User-Programmable Self Tests
332
Control Pushbuttons
333
User-Programmable Pushbuttons
334
Flex State Parameters
340
User-Definable Displays
341
Direct Inputs and Outputs
343
Teleprotection
349
Remote Resources
350
Remote Resources Configuration
350
System Setup
352
Power System
353
Signal Sources
354
Breakers
357
Disconnect Switch Control
362
Flexcurves
367
Phasor Measurement Unit
374
Flexlogic
394
Flexlogic Operands
394
Flexlogic Rules
407
Flexlogic Evaluation
408
Flexlogic Example
408
Flexlogic Equation Editor
413
Flexlogic Timers
413
Flexelements
413
Non-Volatile Latches
418
Grouped Elements
419
Overview
419
Setting Group 1
419
Phase Current
420
Neutral Current
429
Ground Current
433
Breaker Failure (ANSI 50BF)
436
Voltage Elements
447
Sensitive Directional Power (ANSI 32)
453
Control Elements
456
Overview
456
Trip Bus
457
Setting Groups
458
Selector Switch
460
Trip Output
466
Overfrequency (ANSI 81O)
472
Synchrocheck (ANSI 25)
473
Digital Elements
478
Digital Counters
481
Monitoring Elements
483
Autoreclose (ANSI 79)
501
Inputs/Outputs
515
Contact Inputs
515
Virtual Inputs
517
Contact Outputs
518
Virtual Outputs
521
Resetting
521
Direct Inputs and Outputs
522
Teleprotection Inputs and Outputs
526
Transducer Inputs/Outputs
528
Dcma Inputs
528
RTD Inputs
529
Dcma Outputs
530
Testing
534
Test Mode Function
534
Test Mode Forcing
534
Phasor Measurement Unit Test Values
535
Force Contact Inputs
536
Force Contact Outputs
536
GE C60 Instruction Manual (604 pages)
Breaker Protection System
Brand:
GE
| Category:
Protection Device
| Size: 22.76 MB
Table of Contents
Table of Contents
3
1 Introduction
9
Safety Symbols and Definitions
9
General Cautions and Warnings
9
For Further Assistance
10
2 Product Description
13
Description
13
Overview
13
Security
15
Order Codes
19
Order Codes with Enhanced CT/VT Modules
19
Order Codes with Process Bus Modules
23
Replacement Modules
26
Signal Processing
29
UR Signal Processing
29
Specifications
31
Protection Elements
31
User-Programmable Elements
34
Monitoring
36
Metering
37
Inputs
37
Power Supply
39
Outputs
40
Communication Protocols
42
Inter-Relay Communications
43
Cybersentry Security
44
Environmental
44
Type Tests
45
Production Tests
45
Approvals
46
Maintenance
46
3 Installation
47
Unpack and Inspect
47
Panel Cutouts
48
Horizontal Units
48
Vertical Units
49
Rear Terminal Layout
54
Wiring
56
Typical Wiring
56
Dielectric Strength
57
Control Power
57
CT/VT Modules
58
Process Bus Modules
60
Contact Inputs and Outputs
60
Transducer Inputs and Outputs
71
RS232 Faceplate Port
72
CPU Communication Ports
73
Irig-B
75
Direct Input and Output Communications
76
Description
76
Fiber: LED and ELED Transmitters
79
Fiber Laser Transmitters
79
Interface
80
RS422 Interface
84
RS422 and Fiber Interface
86
And Fiber Interface
87
IEEE C37.94 Interface
87
C37.94SM Interface
90
Activate Relay
93
Install Software
94
Enervista Communication Overview
94
System Requirements
95
Install Software
96
Add Device to Software
97
Set IP Address in UR
97
Configure Serial Connection
103
Configure Ethernet Connection
104
Configure Modem Connection
106
Automatic Discovery of UR Devices
106
Connect to the C60
107
Connect to the C60 in Enervista
107
Use Quick Connect Via the Front Panel RS232 Port
108
Use Quick Connect Via a Rear Ethernet Port
109
Set up Cybersentry and Change Default Password
109
Import Settings
110
4 Interfaces
113
Enervista Software Interface
113
Introduction
113
Settings Files
113
Event Viewing
114
File Support
115
Enervista Main Window
115
Protection Summary Window
116
Settings Templates
117
Secure and Lock Flexlogic Equations
121
Settings File Traceability
124
Front Panel Interface
127
Front Panel Display
127
Front Panel Keypad
128
Menu Navigation
128
Menu Hierarchy
128
Changing Settings
129
Faceplate
131
LED Indicators
132
Custom LED Labeling
136
Breaker Control
140
Change Passwords
141
Invalid Password Entry
143
Logic Diagrams
143
Flexlogic Design and Monitoring Using Engineer
144
Design Logic
146
Send File to and from Device
156
Monitor Logic
157
View Front Panel and Print Labels
158
Generate Connectivity Report
159
Preferences
159
Toolbars
163
5 Settings
169
Settings Menu
169
Overview
172
Introduction to Elements
172
Introduction to AC Sources
173
Product Setup
175
Security
175
Display Properties
193
Clear Relay Records
195
Communications
196
Modbus User Map
262
Real Time Clock
262
Fault Reports
266
Oscillography
268
Data Logger
271
Demand
272
User-Programmable Leds
273
User-Programmable Self Tests
277
Control Pushbuttons
277
User-Programmable Pushbuttons
279
Flex State Parameters
284
User-Definable Displays
285
Direct Inputs and Outputs
287
Teleprotection
293
Installation
294
Remote Resources
294
Remote Resources Configuration
294
System Setup
296
AC Inputs
296
Power System
297
Signal Sources
298
Breakers
301
Disconnect Switches
305
Flexcurves
308
Phasor Measurement Unit
315
Flexlogic
335
Flexlogic Operands
335
Flexlogic Rules
347
Flexlogic Evaluation
348
Flexlogic Example
348
Flexlogic Equation Editor
353
Flexlogic Timers
353
Flexelements
353
Non-Volatile Latches
358
Grouped Elements
359
Overview
359
Setting Group 1
359
Phase Current
359
Neutral Current
369
Ground Current
373
Breaker Failure (ANSI 50BF)
376
Voltage Elements
387
Sensitive Directional Power (ANSI 32)
393
Control Elements
396
Overview
396
Trip Bus
397
Setting Groups
398
Selector Switch
400
Trip Output
406
Overfrequency (ANSI 81O)
412
Synchrocheck (ANSI 25)
413
Digital Elements
418
Digital Counters
421
Monitoring Elements
423
Autoreclose (ANSI 79)
441
Inputs/Outputs
455
Contact Inputs
455
Virtual Inputs
457
Contact Outputs
458
Virtual Outputs
461
Resetting
461
Direct Inputs and Outputs
462
Teleprotection Inputs and Outputs
465
Transducer Inputs/Outputs
467
Dcma Inputs
467
RTD Inputs
468
Dcma Outputs
469
Testing
473
Test Mode Function
473
Test Mode Forcing
473
Phasor Measurement Unit Test Values
474
Force Contact Inputs
475
Force Contact Outputs
475
Advertisement
GE C60 Instruction Manual (498 pages)
Breaker Protection System
Brand:
GE
| Category:
Relays
| Size: 9.81 MB
Table of Contents
Table of Contents
3
1 Introduction
9
Safety Symbols and Definitions
9
General Cautions and Warnings
9
For Further Assistance
10
2 Product Description
11
Overview
11
Security
13
Order Codes
16
Order Codes with Enhanced CT/VT Modules
17
Order Codes with Process Bus Modules
20
Replacement Modules
23
Specifications
24
Protection Elements
24
User-Programmable Elements
27
Monitoring
29
Metering
30
Inputs
31
Power Supply
32
Outputs
33
Communication Protocols
35
Inter-Relay Communications
36
Environmental
37
Type Tests
38
Production Tests
38
Approvals
39
Maintenance
39
3 Installation
41
Unpack and Inspect
41
Panel Cutouts
42
Horizontal Units
42
Vertical Units
43
Rear Terminal Layout
47
Wiring
49
Typical Wiring
49
Dielectric Strength
50
Control Power
50
CT/VT Modules
51
Process Bus Modules
52
Contact Inputs and Outputs
53
Transducer Inputs and Outputs
60
RS232 Faceplate Port
62
CPU Communication Ports
62
Irig-B
64
Direct Input and Output Communications
65
Description
65
Fiber: LED and ELED Transmitters
67
Fiber Laser Transmitters
67
Interface
68
RS422 Interface
72
RS422 and Fiber Interface
74
And Fiber Interface
74
IEEE C37.94 Interface
75
C37.94SM Interface
78
Activate Relay
81
Install Software
82
Enervista Communication Overview
82
System Requirements
83
Install Software
83
Configure the C60 for Software Access
84
Configure Serial Communication
85
Configure Ethernet Communication
86
Automatic Discovery of UR Devices
87
Connect to the C60
87
Connect to the C60 in Enervista
87
Use Quick Connect Via the Front Panel RS232 Port
88
Use Quick Connect Via a Rear Ethernet Port
89
Set up Cybersentry and Change Default Password
94
4 Interfaces
97
Enervista Software Interface
97
Introduction
97
Settings Files
97
Event Viewing
98
File Support
98
Enervista Main Window
98
Settings Templates
99
Secure and Lock Flexlogic Equations
104
Settings File Traceability
106
Front Panel Interface
108
Front Panel Display
108
Front Panel Keypad
108
Menu Navigation
109
Menu Hierarchy
109
Changing Settings
110
Faceplate
111
LED Indicators
113
Custom LED Labeling
116
Breaker Control
122
Change Passwords
123
Invalid Password Entry
124
Logic Diagrams
125
5 Settings
127
Settings Menu
127
SETTINGS 5.1 Settings Menu
127
Introduction to Elements
130
Introduction to AC Sources
131
Product Setup
133
Security
133
Display Properties
151
Clear Relay Records
153
Communications
154
Modbus User Map
207
Real Time Clock
208
Fault Reports
212
Oscillography
214
Data Logger
216
Demand
217
User-Programmable Leds
219
User-Programmable Self Tests
222
Control Pushbuttons
223
User-Programmable Pushbuttons
224
Flex State Parameters
229
User-Definable Displays
230
Direct Inputs and Outputs
232
Teleprotection
239
Installation
240
Remote Resources
240
Remote Resources Configuration
240
AC Inputs
241
System Setup
241
Power System
243
Signal Sources
244
Breakers
246
Disconnect Switches
251
Flexcurves
254
Phasor Measurement Unit
261
Flexlogic
281
Flexlogic Operands
281
Flexlogic Evaluation
293
Flexlogic Example
293
Flexlogic Rules
293
Flexelements
298
Flexlogic Equation Editor
298
Flexlogic Timers
298
Non-Volatile Latches
303
Overview
304
Setting Group 1
304
Grouped Elements
304
Phase Current
305
Neutral Current
313
Ground Current
316
Breaker Failure
319
Voltage Elements
329
Supervising Elements
335
Sensitive Directional Power
337
Control Elements
340
Overview
340
Trip Bus
340
Setting Groups
342
Selector Switch
343
Synchrocheck
350
Digital Elements
354
Digital Counters
357
Monitoring Elements
359
Autoreclose
374
Contact Inputs
388
Inputs/Outputs
388
Contact Outputs
390
Virtual Inputs
390
Virtual Outputs
393
Direct Inputs and Outputs
394
Resetting
394
Teleprotection Inputs and Outputs
398
Transducer Inputs/Outputs
400
Dcma Inputs
400
RTD Inputs
400
Dcma Outputs
402
Testing
405
Test Mode Function
405
Test Mode Forcing
406
Force Contact Inputs
407
Force Contact Outputs
407
Phasor Measurement Unit Test Values
408
GE C60 Communications Manual (532 pages)
Universal Relay Family
Brand:
GE
| Category:
Relays
| Size: 3.79 MB
Table of Contents
Table of Contents
3
1 Introduction
7
Products
7
Features Per Product
7
Communication Ports
20
Safety Symbols and Definitions
20
For Further Assistance
20
Modbus
21
2 Modbus Communication
21
Modbus RTU Protocol
21
Introduction
21
Configuration
21
Physical Layer
21
Data Link Layer
22
Modbus RTU CRC-16 Algorithm
23
Modbus Function Codes
24
Supported Function Codes
24
Read Actual Values or Settings (Function Code 03/04H)
24
Execute Operation (Function Code 05H)
25
Store Single Setting (Function Code 06H)
25
Store Multiple Settings (Function Code 10H)
26
Exception Responses
26
File Transfers
27
Obtaining Relay Files Using Modbus
27
Memory Map
32
Modbus Memory Map
32
6 Iec 60870-5-104
80
Communication
81
Data Formats
204
3 Iec 61850 Communication
239
Overview
239
Introduction
239
Abstract Communication Service Interface (ASCI)
241
Datasets
244
Txgoose
245
Rxgoose
247
Reports
248
Commands
250
Substation Configuration Language (SCL)
250
Configuring the UR Using SCL
256
Merge SCL File
261
Configurable Logical Devices
262
Protocol Implementation Conformance Statement (PICS)
262
Basic Conformance Statement
262
ACSI Conformance Statement
263
ACSI Basic Conformance Statement
263
ACSI Models Conformance Statement
263
ACSI Services Conformance Statement
265
Model Implementation Conformance Statement (MICS)
267
Master (Root) Logical Device
268
Protection (Prot) Logical Device
275
Control (Ctrl) Logical Device
354
System Logical Device
389
Meter Logical Device
410
General (Gen) Logical Device
431
GE Namespace
447
Enumerations
462
SCL Implementation Conformance Statement (SICS)
463
PIXIT Conformance Statement
465
TICS Conformance Statement
470
SCL Logging
472
Overview of Process
472
SCL File Storage on UR
473
Generation of CID Files
473
Schema Version Used by Ur/Enervista
473
CID File Processing Steps
473
SCL Log File Format and Examples
473
Troubleshooting Log File Errors
475
G2 Implementation Model for GOOSE Configuration Via SCL
475
Introduction
475
Configuration Process
476
Configuration Process with IED Setup Tool
478
IED Capability Description (ICD) File
478
Instantiated IED Capability Description (IID) File
482
Configured IED Description (CID) File
482
Sample SCL Files
484
Annex - Optional Intermediate GOOSE Reception Objects
489
E3-2.0 Implementation Model for GOOSE Configuration Via SCL
492
Introduction
492
Workflow
492
ICD Files
493
CID Files
494
IID Files
495
GE C60 Communications Manual (526 pages)
UR Family
Brand:
GE
| Category:
Controller
| Size: 3.78 MB
Table of Contents
Table of Contents
3
1 Introduction
7
Products
7
Features Per Product
7
Communication Ports
20
Safety Symbols and Definitions
20
For Further Assistance
20
Modbus
21
2 Modbus Communication
21
Modbus RTU Protocol
21
Introduction
21
Configuration
21
Physical Layer
21
Data Link Layer
22
Modbus RTU CRC-16 Algorithm
23
Modbus Function Codes
24
Supported Function Codes
24
Read Actual Values or Settings (Function Code 03/04H)
24
Execute Operation (Function Code 05H)
25
Store Single Setting (Function Code 06H)
25
Store Multiple Settings (Function Code 10H)
26
Exception Responses
26
File Transfers
27
Obtaining Relay Files Using Modbus
27
Memory Map
32
Modbus Memory Map
32
6 Iec 60870-5-104
80
Communication
81
Data Formats
203
3 Iec 61850 Communication
239
Overview
239
Introduction
239
Abstract Communication Service Interface (ASCI)
241
Datasets
244
Txgoose
245
Rxgoose
247
Reports
248
Commands
250
Substation Configuration Language (SCL)
250
Configuring the UR Using SCL
256
Merge SCL File
261
Configurable Logical Devices
262
Protocol Implementation Conformance Statement (PICS)
262
Basic Conformance Statement
262
ACSI Conformance Statement
263
ACSI Basic Conformance Statement
263
ACSI Models Conformance Statement
263
ACSI Services Conformance Statement
265
Model Implementation Conformance Statement (MICS)
267
Master (Root) Logical Device
268
Protection (Prot) Logical Device
275
Control (Ctrl) Logical Device
351
System Logical Device
385
Meter Logical Device
406
General (Gen) Logical Device
426
GE Namespace
442
Enumerations
457
SCL Implementation Conformance Statement (SICS)
458
PIXIT Conformance Statement
460
TICS Conformance Statement
465
SCL Logging
467
Overview of Process
467
SCL File Storage on UR
468
Generation of CID Files
468
Schema Version Used by Ur/Enervista
468
CID File Processing Steps
468
SCL Log File Format and Examples
468
Troubleshooting Log File Errors
470
G2 Implementation Model for GOOSE Configuration Via SCL
470
Introduction
470
Configuration Process
471
Configuration Process with IED Setup Tool
473
IED Capability Description (ICD) File
473
Instantiated IED Capability Description (IID) File
477
Configured IED Description (CID) File
477
Sample SCL Files
479
Annex - Optional Intermediate GOOSE Reception Objects
484
E3-2.0 Implementation Model for GOOSE Configuration Via SCL
487
Introduction
487
Workflow
487
ICD Files
488
CID Files
489
IID Files
490
GE C60 Instruction Manual (320 pages)
Multilin Breaker Management Relay UR Series
Brand:
GE
| Category:
Relays
| Size: 4.51 MB
Table of Contents
Table of Contents
5
1 Getting Started
11
Important Procedures
11
Cautions and Warnings
11
Inspection Checklist
11
Ur Overview
12
Introduction to the Ur Relay
12
Ur Hardware Architecture
13
Ur Software Architecture
14
Important Ur Concepts
14
Urpc ® Software
15
Pc Requirements
15
Software Installation
15
Connecting Urpc ® with the C60
16
Ur Hardware
18
Mounting and Wiring
18
Communications
18
Faceplate Display
18
Using the Relay
19
Faceplate Keypad
19
Menu Navigation
19
Menu Hierarchy
19
Relay Activation
20
Battery Tab
20
Relay Passwords
20
Flexlogic™ Customization
20
Commissioning
20
2 Product Description
21
Introduction
21
Overview
21
Ordering
23
Specifications
25
Protection Elements
25
User-Programmable Elements
26
Monitoring
26
Metering
27
Inputs
27
Power Supply
29
Outputs
29
Communications
29
Environmental
29
Type Tests
30
Approvals
30
Maintenance
30
3 Hardware
31
Description
31
Panel Cutout
31
Module Withdrawal/Insertion
34
Rear Terminal Layout
35
Rear Terminal Assignments
35
Wiring
36
Typical Wiring
36
Dielectric Strength Ratings and Testing
37
Control Power
37
Ct/Vt Modules
38
Contact Inputs/Outputs
40
Transducer Inputs/Outputs
46
Rs232 Faceplate Program Port
47
Cpu Communication Ports
47
Irig-B
49
4 Human Interfaces
51
Urpc ® Software Interface
51
Graphical User Interface
51
Creating a Site List
51
Urpc ® Software Overview
51
Urpc Software Main Window
53
Faceplate Interface
54
Faceplate
54
Led Indicators
55
CUSTOM LABELING of Leds
57
Customizing the Led Display
57
Display
58
Keypad
58
Breaker Control
59
Menus
60
Changing Settings
61
5 Settings
61
Overview
65
Settings Main Menu
65
Introduction to Elements
67
Introduction to Ac Sources
68
Product Setup
71
Password Security
71
Display Properties
72
Communications
72
Modbus User Map
79
Real Time Clock
79
Fault Report
79
Oscillography
80
Data Logger
82
Demand
82
User-Programmable Leds
84
Flex State Parameters
85
User-Definable Displays
85
Installation
87
System Setup
88
Ac Inputs
88
Power System
89
Signal Sources
90
Line
92
Breakers
93
Introduction to Flexlogic
96
Flexlogic™ Rules
101
Flexlogic™ Evaluation
102
Flexlogic™ Procedure Example
102
Flexlogic Equation Editor
107
Flexlogic Timers
107
Flexelements
108
Grouped Elements
112
Overview
112
Setting Group
112
Breaker Failure
112
Voltage Elements
122
Control Elements
126
Overview
126
Setting Groups
126
Synchrocheck
127
Autoreclose
131
Digital Elements
142
Digital Counters
145
Monitoring Elements
147
Inputs / Outputs 5.7.1 Contact Inputs
149
Virtual Inputs
151
Uca Sbo Timer
152
Virtual Outputs
153
Remote Inputs
154
Remote Outputs: Dna Bit Pairs
155
REMOTE OUTPUTS: Userst BIT PAIRS
156
Transducer I/O 5.8.1 Dcma Inputs
157
Rtd Inputs
158
Testing 5.9.1 Test Mode
159
Actual Values Main Menu
161
Virtual Inputs
163
Contact Outputs
164
Remote Devices Statistics
165
Sources
169
Synchrocheck
172
Tracking Frequency
173
Fault Locator Operation
174
Event Records
176
Maintenance
177
Model Information
178
Clear Records
179
Set Date and Time
179
Relay Maintenance
179
Virtual Inputs
179
Targets Menu
181
Target Messages
181
Relay Self-Tests
181
Advertisement
Related Products
GE C30
GE CTS18FBSDRWW and
GE CA16DK
GE C2S986
GE CHS995
GE CCHS995SEL1SS
GE Advantium CSB923M2NS5
GE CV48S
GE CP9530*J series
GE CB25DF
GE Categories
Refrigerator
Ranges
Microwave Oven
Air Conditioner
Dishwasher
More GE Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL