KX-TG4061LAT/KX-TG4062LAT/KX-TG4063LAT/KX-TG4071LAT/KX-TG4072LAT/KX-TG4073LAT/KX-TGA403LAT 1 Safety Precautions 1.1. For Service Technicians • Repair service shall be provided in accordance with repair technology information such as service manual so as to prevent fires, injury or electric shock, which can be caused by improper repair work.
KX-TG4061LAT/KX-TG4062LAT/KX-TG4063LAT/KX-TG4071LAT/KX-TG4072LAT/KX-TG4073LAT/KX-TGA403LAT 2.2.1. Suggested PbF Solder There are several types of PbF solder available commercially. While this product is manufactured using Tin, Silver, and Copper (Sn+Ag+Cu), you can also use Tin and Copper (Sn+Cu), or Tin, Zinc, and Bismuth (Sn+Zn+Bi). Please check the manufacturer's specific instructions for the melting points of their products and any precautions for using their product with other materials.
KX-TG4061LAT/KX-TG4062LAT/KX-TG4063LAT/KX-TG4071LAT/KX-TG4072LAT/KX-TG4073LAT/KX-TGA403LAT 4 Technical Descriptions 4.1. US-DECT Description The frequency range of 1.91 GHz-1.93 GHz is used. Transmitting and receiving carrier between base unit and handset is same frequency. Refer to Frequency Table (P.62). 4.1.1. TDD Frame Format 4.1.2. TDMA system This system is the cycles of 10 ms, and has 6 duplex paths, but maximum duplex communication path is 5 because of dummy bearer use.
Page 8
KX-TG4061LAT/KX-TG4062LAT/KX-TG4063LAT/KX-TG4071LAT/KX-TG4072LAT/KX-TG4073LAT/KX-TGA403LAT 4.1.3. Signal Flowchart in the Radio Parts Reception A voice signal from TEL line is encoded to digital data "TXDATA" by BBIC (IC501) in a base unit. Then TXDATA goes to RF PART and it's modulated to 1.9 GHz. The RF signal is amplified and fed to a selected antenna.
KX-TG4061LAT/KX-TG4062LAT/KX-TG4063LAT/KX-TG4071LAT/KX-TG4072LAT/KX-TG4073LAT/KX-TGA403LAT 4.4. Circuit Operation (Base Unit) 4.4.1. KX-TG4061 General Description: (BBIC, EERROM) is a digital speech/signal processing system that implements all the functions of speech compression and memory management required in a digital telephone. The BBIC system is fully controlled by a host processor. The host processor provides activation and control of all that functions as follows.
Page 13
KX-TG4061LAT/KX-TG4062LAT/KX-TG4063LAT/KX-TG4071LAT/KX-TG4072LAT/KX-TG4073LAT/KX-TGA403LAT 4.4.2. KX-TG4071 General Description: (BBIC, Flash Memory, EERROM) is a digital speech/signal processing system that implements all the functions of speech compression, record and playback, and memory management required in a digital telephone answering machine. The BBIC system is fully controlled by a host processor. The host processor provides activation and control of all that functions as follows.
Page 14
KX-TG4061LAT/KX-TG4062LAT/KX-TG4063LAT/KX-TG4071LAT/KX-TG4072LAT/KX-TG4073LAT/KX-TGA403LAT 4.4.3. Power Supply Circuit/Reset Circuit The power supply voltage from AC adaptor is converted to VBAT (3.0V) in IC302. And +3.0V for peripherals and analog part is insulated from VBAT by Doubler of BBIC. Circuit Operation:...
KX-TG4061LAT/KX-TG4062LAT/KX-TG4063LAT/KX-TG4071LAT/KX-TG4072LAT/KX-TG4073LAT/KX-TGA403LAT 4.4.3.1. Charge Circuit The voltage from the AC adaptor is supplied to the charge circuits.
KX-TG4061LAT/KX-TG4062LAT/KX-TG4063LAT/KX-TG4071LAT/KX-TG4072LAT/KX-TG4073LAT/KX-TGA403LAT 4.4.4. Telephone Line Interface Telephone Line Interface Circuit: Function • Bell signal detection • ON/OFF hook and pulse dial circuit • Side tone circuit Bell signal detection and OFF HOOK circuit: In the idle mode, Q141 is open to cut the DC loop current and decrease the ring load. When ring voltage appears at the Tip (T) and Ring (R) leads (When the telephone rings), the AC ring voltage is transferred as follows: T →...
Page 17
KX-TG4061LAT/KX-TG4062LAT/KX-TG4063LAT/KX-TG4071LAT/KX-TG4072LAT/KX-TG4073LAT/KX-TGA403LAT 4.4.5. Parallel Connection Detect Circuit/Auto Disconnect Circuit Function: In order to disable call waiting and stutter tone functions when using telephones connected in parallel, it is necessary to have a circuit that judges whether a telephone connected in parallel is in use or not. This circuit determines whether the telephone connected in parallel is on hook or off hook by detecting changes in the T/R voltage.
Page 18
KX-TG4061LAT/KX-TG4062LAT/KX-TG4063LAT/KX-TG4071LAT/KX-TG4072LAT/KX-TG4073LAT/KX-TGA403LAT 4.4.6. Calling Line Identification (Caller ID)/Call Waiting Caller ID Function: Caller ID The caller ID is a chargeable ID which the user of a telephone circuit obtains by entering a contract with the telephone company to utilize a caller ID service. For this reason, the operation of this circuit assumes that a caller ID service contract has been entered for the circuit being used.
Page 19
KX-TG4061LAT/KX-TG4062LAT/KX-TG4063LAT/KX-TG4071LAT/KX-TG4072LAT/KX-TG4073LAT/KX-TGA403LAT Call Waiting Caller ID Calling Identity Delivery on Call Waiting (CIDCW) is a CLASS service that allows a customer, while off-hook on an existing call, to receive information about a calling party on a waited call. The transmission of the calling information takes place almost immediately after the customer is alerted to the new call so he/she can use this information to decide whether to take the new call.
KX-TG4061LAT/KX-TG4062LAT/KX-TG4063LAT/KX-TG4071LAT/KX-TG4072LAT/KX-TG4073LAT/KX-TGA403LAT 4.7. Circuit Operation (Handset) 4.7.1. Outline Handset consists of the following ICs as shown in Block Diagram (Handset) (P.20). • DECT BBIC (Base Band IC): IC1 - All data signals (forming/analyzing ACK or CMD signal) - All interfaces (ex: Key, Detector Circuit, Charge, DC/DC Converter, EEPROM, LCD, RF Power Amp.)
Page 23
KX-TG4061LAT/KX-TG4062LAT/KX-TG4063LAT/KX-TG4071LAT/KX-TG4072LAT/KX-TG4073LAT/KX-TGA403LAT 4.7.3. Charge Circuit Circuit Operation: When charging the handset on the Base Unit, the charge current is as follows; DC+(6.5 V) → F301 → R371 → R372 →CHARGE+(Base) → CHARGE+(Handset) → Q4 → D7→ F1 → BATTERY+... Battery... BATTERY- → R45 → GND → CHARGE-(Handset)→ CHARGE-(Base) → GND → DC-(GND) In this way, the BBIC on Handset detects the fact that the battery is charged.
KX-TG4061LAT/KX-TG4062LAT/KX-TG4063LAT/KX-TG4071LAT/KX-TG4072LAT/KX-TG4073LAT/KX-TGA403LAT 4.8. Circuit Operation (Charger Unit) Charge control is executed at handset side so that the operation when using charger is also controlled by handset. Refer to Circuit Operation (Handset) (P.22) The route for this is as follows: DC+pin of J1(+) → F1 → R1 → CHARGE+pad → Handset → CHARGE-pad → DC-pin of J1(-).
KX-TG4061LAT/KX-TG4062LAT/KX-TG4063LAT/KX-TG4071LAT/KX-TG4072LAT/KX-TG4073LAT/KX-TGA403LAT 5 Location of Controls and Components Refer to the Operating Instructions. Note: You can download and refer to the Operating Instructions (Instruction book) on TSN Server. 6 Installation Instructions Refer to the Operating Instructions. Note: You can download and refer to the Operating Instructions (Instruction book) on TSN Server.
KX-TG4061LAT/KX-TG4062LAT/KX-TG4063LAT/KX-TG4071LAT/KX-TG4072LAT/KX-TG4073LAT/KX-TGA403LAT 8 Test Mode 8.1. Engineering Mode 8.1.1. Base Unit...
Page 30
KX-TG4061LAT/KX-TG4062LAT/KX-TG4063LAT/KX-TG4071LAT/KX-TG4072LAT/KX-TG4073LAT/KX-TGA403LAT Frequently Used Items (Base Unit) ex.) Items Address Default Data New Data Remarks Frequency 00 07 / 00 08 00/01 Use these items in a READ-ONLY mode to confirm the contents. Careless rewriting may 00 02 ~ 00 06 Given value cause serious damage to the computer system.
Page 32
KX-TG4061LAT/KX-TG4062LAT/KX-TG4063LAT/KX-TG4071LAT/KX-TG4072LAT/KX-TG4073LAT/KX-TGA403LAT Frequently Used Items (Handset) ex.) Items Address Default Data New Data Possible Adjusted Possible Adjusted Remarks Value MAX (hex) Value MIN (hex) Battery Low 00 11 / 00 12 00 / 00 (*2) Frequency 00 07 / 00 08...
KX-TG4061LAT/KX-TG4062LAT/KX-TG4063LAT/KX-TG4071LAT/KX-TG4072LAT/KX-TG4073LAT/KX-TGA403LAT 9 Service Mode 9.1. How to Clear User Setting (Handset Only) Handset Press simultaneously until a beep sound is heard. Then single handset is initialized. (The contents of user setting are reset to factory default) *Usage time is not cleared.
KX-TG4061LAT/KX-TG4062LAT/KX-TG4063LAT/KX-TG4071LAT/KX-TG4072LAT/KX-TG4073LAT/KX-TGA403LAT 10.1.1. Check Power 10.1.1.1. Base Unit Cross Reference: Note: Power Supply Circuit/Reset Circuit (P.14) BBIC is IC501. (*1) Refer to Specifications (P.6) for part number and supply voltage of AC adaptor. (*2) Refer to Circuit Board (Base Unit_Main) (P.81).
KX-TG4061LAT/KX-TG4062LAT/KX-TG4063LAT/KX-TG4071LAT/KX-TG4072LAT/KX-TG4073LAT/KX-TGA403LAT 10.1.2. Check Record (KX-TG4071/4072/4073 only) 10.1.2.1. Base Unit A) Not record Incoming Message Cross Reference: Note: Signal Route (P.25) Flash Memory is IC601. Telephone Line Interface (P.16) BBIC is IC501. Parallel Connection Detect Circuit/Auto Disconnect Circuit (P.17)
KX-TG4061LAT/KX-TG4062LAT/KX-TG4063LAT/KX-TG4071LAT/KX-TG4072LAT/KX-TG4073LAT/KX-TGA403LAT 10.1.5. Check Link 10.1.5.1. Base Unit Cross Reference: Power Supply Circuit/Reset Circuit (P.14) Check the RF part (P.40) Note: *1 How to adjust +3.0V: Execute the command "VDA" Refer to Things to Do after Replacing IC or X'tal (P.60) for Base Unit.
Page 39
KX-TG4061LAT/KX-TG4062LAT/KX-TG4063LAT/KX-TG4071LAT/KX-TG4072LAT/KX-TG4073LAT/KX-TGA403LAT 10.1.5.2. Handset Cross Reference: Power Supply Circuit/Reset Circuit (P.22) Check the RF part (P.40) Note: *1 How to adjust the frequency of X1: To see the frequency, execute the command “SFR“, then check the TP_CKM (IC1-46pin). To adjust frequency, send command “SFR “...
KX-TG4061LAT/KX-TG4062LAT/KX-TG4063LAT/KX-TG4071LAT/KX-TG4072LAT/KX-TG4073LAT/KX-TGA403LAT 10.1.6. Check the RF part 10.1.6.1. Finding out the Defective part After All the Checkings or Repairing 1. Re-register the checked handset to the checked base unit, and Regular HS to Regular BU. Note: (*1) HS: Handset (*2) BU: Base Unit...
Page 41
KX-TG4061LAT/KX-TG4062LAT/KX-TG4063LAT/KX-TG4071LAT/KX-TG4072LAT/KX-TG4073LAT/KX-TGA403LAT 10.1.6.2. RF Check Flowchart Each item (1 ~ 6) of RF Check Flowchart corresponds to Check Table for RF part (P.42). Please refer to the each item. Note: (*1) Refer to Check Link (P.38).
Page 42
KX-TG4061LAT/KX-TG4062LAT/KX-TG4063LAT/KX-TG4071LAT/KX-TG4072LAT/KX-TG4073LAT/KX-TGA403LAT 10.1.6.3. Check Table for RF part Item BU (Base Unit) Check HS (Handset) Check Link Confirmation Normal 1. Register Regular HS to BU (to be 1. Register HS (to be checked) to Regular checked). HS, BU Mode [Normal Mode] 2.
Page 43
KX-TG4061LAT/KX-TG4062LAT/KX-TG4063LAT/KX-TG4071LAT/KX-TG4072LAT/KX-TG4073LAT/KX-TGA403LAT 10.1.6.4. TEST RANGE Check Circuit block which range is defective can be found by the following check. Item BU (Base Unit) Check HS (Handset) Check Range Confirmation TX TEST 1. Register Regular HS to BU (to be checked). 1. Register HS (to be checked) to Regular BU.
Page 44
KX-TG4061LAT/KX-TG4062LAT/KX-TG4063LAT/KX-TG4071LAT/KX-TG4072LAT/KX-TG4073LAT/KX-TGA403LAT 10.1.7. Registering a Handset to the Base Unit 10.1.8. Deregistering a Handset 10.1.9. Deregistering All Handsets by the Base Unit...
KX-TG4061LAT/KX-TG4062LAT/KX-TG4063LAT/KX-TG4071LAT/KX-TG4072LAT/KX-TG4073LAT/KX-TGA403LAT 10.1.10. Check Handset Transmission Cross Reference: Signal Route (P.25) 10.1.11. Check Handset Reception Cross Reference: Signal Route (P.25) Note: When checking the RF part, Refer to Check the RF part (P.40). 10.1.12. Check Caller ID Cross Reference: Telephone Line Interface (P.16) Calling Line Identification (Caller ID)/Call Waiting Caller ID (P.18)
KX-TG4061LAT/KX-TG4062LAT/KX-TG4063LAT/KX-TG4071LAT/KX-TG4072LAT/KX-TG4073LAT/KX-TGA403LAT 11 Disassembly and Assembly Instructions 11.1. Disassembly Instructions 11.1.1. Base Unit 11.1.1.1. KX-TG4061...
KX-TG4061LAT/KX-TG4062LAT/KX-TG4063LAT/KX-TG4071LAT/KX-TG4072LAT/KX-TG4073LAT/KX-TGA403LAT 11.2. How to Replace the Handset LCD Note: The illustrations are simplified in this page. They may differ from the actual product.
KX-TG4061LAT/KX-TG4062LAT/KX-TG4063LAT/KX-TG4071LAT/KX-TG4072LAT/KX-TG4073LAT/KX-TGA403LAT 12 Measurements and Adjustments This chapter explains the measuring equipment, the JIG connection, and the PC setting method necessary for the measurement in Troubleshooting Guide (P.34) 12.1. Equipment Required • Digital multi-meter (DMM): it must be able to measure voltage and current.
Page 53
KX-TG4061LAT/KX-TG4062LAT/KX-TG4063LAT/KX-TG4071LAT/KX-TG4072LAT/KX-TG4073LAT/KX-TGA403LAT 12.2.2. Connections (Handset) Connect the DC Power or Battery to BATT+ and BATT-. Connect the JIG cable GND (black) to GND. Connect the JIG cable UTX (yellow) to UTX and URX (red) to URX. Note: *: COM port names may vary depending on what your PC calls it.
Page 54
KX-TG4061LAT/KX-TG4062LAT/KX-TG4063LAT/KX-TG4071LAT/KX-TG4072LAT/KX-TG4073LAT/KX-TGA403LAT 12.2.3. How to install Batch file into P.C. Note: • “*****” varies depending on the country or models.
Page 55
KX-TG4061LAT/KX-TG4062LAT/KX-TG4063LAT/KX-TG4071LAT/KX-TG4072LAT/KX-TG4073LAT/KX-TGA403LAT 12.2.4. Commands 12.2.4.1. Commands (Base Unit) See the table below for frequently used commands. Command name Function Example rdeeprom Read the data of EEPROM Type “rdeeprom 00 00 FF”, and the data from address “00 00” to “FF” is read out.
KX-TG4061LAT/KX-TG4062LAT/KX-TG4063LAT/KX-TG4071LAT/KX-TG4072LAT/KX-TG4073LAT/KX-TGA403LAT 12.3. Adjustment Standard (Base Unit) When connecting the simulator equipment for checking, please refer to below. 12.3.1. Bottom View 12.3.1.1. KX-TG4061 Note: (*1) is referred to No.2 of Check Check Table for RF part (P.42) (*2) is referred to Power Supply Circuit/Reset Circuit (P.14)
Page 57
KX-TG4061LAT/KX-TG4062LAT/KX-TG4063LAT/KX-TG4071LAT/KX-TG4072LAT/KX-TG4073LAT/KX-TGA403LAT 12.3.1.2. KX-TG4071 Note: (*1) is referred to No.2 of Check Check Table for RF part (P.42) (*2) is referred to Power Supply Circuit/Reset Circuit (P.14)
KX-TG4061LAT/KX-TG4062LAT/KX-TG4063LAT/KX-TG4071LAT/KX-TG4072LAT/KX-TG4073LAT/KX-TGA403LAT 12.4. Adjustment Standard (Charger Unit) When connecting the simulator equipment for checking, please refer to below. 12.4.1. Bottom View Digital Volt Meter /2 W DC POWER DC 6.5 V...
KX-TG4061LAT/KX-TG4062LAT/KX-TG4063LAT/KX-TG4071LAT/KX-TG4072LAT/KX-TG4073LAT/KX-TGA403LAT 12.6. Things to Do after Replacing IC or X'tal If repairing or replacing EEPROM and X'tal, it is necessary to download the required data such as Programming data or adjustment data, etc. in memory. The set doesn't operate if it is not executed.
Page 61
KX-TG4061LAT/KX-TG4062LAT/KX-TG4063LAT/KX-TG4071LAT/KX-TG4072LAT/KX-TG4073LAT/KX-TGA403LAT 12.6.1.2. Handset First, operate the PC setting according to The Setting Method of JIG (P.52). Then download the appropriate data according to the following procedures. Items How to download/Required adjustment EEPROM (IC3) Adjusted parameter data is 1) Default batch file: Execute the command “default.bat”.
KX-TG4061LAT/KX-TG4062LAT/KX-TG4063LAT/KX-TG4071LAT/KX-TG4072LAT/KX-TG4073LAT/KX-TGA403LAT 13 Miscellaneous 13.1. How to Replace the Flat Package IC Even if you do not have the special tools (for example, a spot heater) to remove the Flat IC, with some solder (large amount), a soldering iron and a cutter knife, you can easily remove the ICs that have more than 100 pins.
Page 64
KX-TG4061LAT/KX-TG4062LAT/KX-TG4063LAT/KX-TG4071LAT/KX-TG4072LAT/KX-TG4073LAT/KX-TGA403LAT 13.1.3. How to Install the IC 1. Temporarily fix the FLAT PACKAGE IC, soldering the two marked pins. *Check the accuracy of the IC setting with the corresponding soldering foil. 2. Apply flux to all pins of the FLAT PACKAGE IC.
KX-TG4061LAT/KX-TG4062LAT/KX-TG4063LAT/KX-TG4071LAT/KX-TG4072LAT/KX-TG4073LAT/KX-TGA403LAT 13.2. How to Replace the Shield Case 13.2.1. Preparation • PbF (: Pb free) Solder • Soldering Iron Tip Temperature of 700°F ± 20°F (370°C ± 10°C) Note: We recommend a 30 to 40 Watt soldering iron. An expert may be able to use a 60 to 80 Watt iron where someone with less experience could overheat and damage the PCB foil.
Page 66
KX-TG4061LAT/KX-TG4062LAT/KX-TG4063LAT/KX-TG4071LAT/KX-TG4072LAT/KX-TG4073LAT/KX-TGA403LAT 13.2.4. How to Install the Shield Case Note: • If you don’t have special tools (ex. Hot air disordering tool), conduct the following operations. • Shield case’s No. : PNMC1013Z 1. Put the shield case. 2. Solder the surroundings.
KX-TG4061LAT/KX-TG4062LAT/KX-TG4063LAT/KX-TG4071LAT/KX-TG4072LAT/KX-TG4073LAT/KX-TGA403LAT 13.3. How to Replace the LLP (Leadless Leadframe Package) IC Note: This description is only applied on the model with Shield case. 13.3.1. Preparation • PbF (: Pb free) Solder • Soldering Iron Tip Temperature of 700 °F ± 20 °F (370 °C ± 10 °C) Note: We recommend a 30 to 40 Watt soldering iron.
Page 68
KX-TG4061LAT/KX-TG4062LAT/KX-TG4063LAT/KX-TG4071LAT/KX-TG4072LAT/KX-TG4073LAT/KX-TGA403LAT 13.3.4. How to Install the IC 1. Place the solder a little on the land where the radiation GND pad on IC bottom is to be attached. 2. Place the solder a little on the land where IC pins are to be attached, then place the IC.
KX-TG4061LAT/KX-TG4062LAT/KX-TG4063LAT/KX-TG4071LAT/KX-TG4072LAT/KX-TG4073LAT/KX-TGA403LAT 13.4. Terminal Guide of the ICs, Transistors and Diodes 13.4.1. Base Unit * KX-TG4071/4072/4073 only 13.4.2. Handset...
KX-TG4061LAT/KX-TG4062LAT/KX-TG4063LAT/KX-TG4071LAT/KX-TG4072LAT/KX-TG4073LAT/KX-TGA403LAT 14 Schematic Diagram 14.1. For Schematic Diagram 14.1.1. Base Unit (Schematic Diagram (Base Unit_Main)) Notes: 1. DC voltage measurements are taken with voltmeter from the negative voltage line. 2. The schematic diagrams may be modified at any time with the development of new technology.
Page 79
KX-TG4061LAT/KX-TG4062LAT/KX-TG4063LAT/KX-TG4071LAT/KX-TG4072LAT/KX-TG4073LAT/KX-TGA403LAT R807 W 0.15mm RXON L 20+/-2mm 3rd layer C827 L801 TP_ANT1 *C826 RX_RF C803 RF_RXn 1.5p DA801 BATTERY RF_RXp W 0.125mm L 7.6mm Gap 0.125mm W 0.15mm W 0.15mm CP+3.0V 1st layer L 5.0mm L 5.0mm 1st layer 1st layer...
KX-TG4061LAT/KX-TG4062LAT/KX-TG4063LAT/KX-TG4071LAT/KX-TG4072LAT/KX-TG4073LAT/KX-TGA403LAT 16 Exploded View and Replacement Parts List 16.1. Cabinet and Electrical Parts (Base Unit) 16.1.1. KX-TG4061 Note: (*1) The SPACERs (No.7) are cut from the excess parts of SPACER (No.108) of Cabinet and Electrical Parts (Handset) (P.90).
Page 89
KX-TG4061LAT/KX-TG4062LAT/KX-TG4063LAT/KX-TG4071LAT/KX-TG4072LAT/KX-TG4073LAT/KX-TGA403LAT 16.1.2. KX-TG4071 Note: (*1) The SPACERs (No.14) are cut from the excess parts of SPACER (No.108) of Cabinet and Electrical Parts (Handset) (P.90).
(*1) This cable is fixed by welding. Refer to How to Replace the Handset LCD (P.51). (*2) The rechargeable Ni-MH battery HHR-4DPA or HHR-4MRT is available through sales route of Panasonic. (*3) Attach the SPACER (No. 119) to the exact location described above.
KX-TG4061LAT/KX-TG4062LAT/KX-TG4063LAT/KX-TG4071LAT/KX-TG4072LAT/KX-TG4073LAT/KX-TGA403LAT 16.5. Replacement Parts List 16.5.1.1.2. KX-TG4071 1. RTL (Retention Time Limited) Note: Safety Ref. Part No. Part Name & Description Remarks The “RTL” marking indicates that its Retention Time is Limited. PNKM1132V3 CABINET BODY PS-HB K2ECYZ000001 JACK, DC When production is discontinued, this item will...
Page 94
KX-TG4061LAT/KX-TG4062LAT/KX-TG4063LAT/KX-TG4071LAT/KX-TG4072LAT/KX-TG4073LAT/KX-TGA403LAT Safety Ref. Part No. Part Name & Description Remarks Safety Ref. Part No. Part Name & Description Remarks R122 ERJ3GEYJ394 390k C479 ECUE1H100DCQ 10p R131 PQ4R18XJ106 C501 ECUE1A104KBQ 0.1 R133 ERJ3GEYJ334 330k C502 ECJ1VB0G106M 10 R141 ERJ3GEYJ104 100k C503...
Page 95
KX-TG4061LAT/KX-TG4062LAT/KX-TG4063LAT/KX-TG4071LAT/KX-TG4072LAT/KX-TG4073LAT/KX-TGA403LAT Safety Ref. Part No. Part Name & Description Remarks Safety Ref. Part No. Part Name & Description Remarks Q651 B1GFCFEN0011 TRANSISTOR(SI) R891 ERJ2GEJ471 (DIODES) R892 ERJ2GEJ471 D101 PQVDMD5S DIODE(SI) (CAPACITORS) D113 MA111 DIODE(SI) C101 F1K2H681A008 680p D133 MA111 DIODE(SI)
Page 96
KX-TG4061LAT/KX-TG4062LAT/KX-TG4063LAT/KX-TG4071LAT/KX-TG4072LAT/KX-TG4073LAT/KX-TGA403LAT Safety Ref. Part No. Part Name & Description Remarks Safety Ref. Part No. Part Name & Description Remarks C826 ECUE1H100DCQ 10p C827 ECUE1H100DCQ 10p PCB100 PNWPGA403LAR MAIN P.C.BOARD ASS'Y C859 F1G1H2R2A765 2.2p (RTL) (*1) C863 F1G1H1R5A765 1.5p (ICs) C891...
Page 97
KX-TG4061LAT/KX-TG4062LAT/KX-TG4063LAT/KX-TG4071LAT/KX-TG4072LAT/KX-TG4073LAT/KX-TGA403LAT Safety Ref. Part No. Part Name & Description Remarks Safety Ref. Part No. Part Name & Description Remarks R225 ERJ2GE0R00 C826 F1G1H4R0A765 4p R231 ERJ2GEJ824 820k C827 ECUE1H100DCQ 10p R232 ERJ2GEJ434X 430k C834 F1G1H1R0A765 1p R248 ERJ2GE0R00 C860 ECUE1H100DCQ 10p...
Page 98
KX-TG4061LAT/KX-TG4062LAT/KX-TG4063LAT/KX-TG4071LAT/KX-TG4072LAT/KX-TG4073LAT/KX-TGA403LAT (*2) When replacing the Handset LCD, See How to Replace the Handset LCD (P.51) Safety Ref. Part No. Part Name & Description Remarks PQZZ1CD300E JIG CABLE (*1) PNZZTG4011LA BATCH FILE CD-ROM (*1)(for KX-TG4061/4062/ 4063) PNZZTG4021LA BATCH FILE CD-ROM (*1)