Chapter 2: Convenient Features Useful features and the detail of system BIOS settings, RAID Configuration Utility, and EXPRESSBUILDER Chapter 3: Appendix Error messages and Windows Event Logs Other documents Provides the detail of NEC ESMPRO, Universal RAID Utility, and the other features. Express5800/R120d-2E User’s Guide...
Status Indicators ..........................44 4.7.1 POWER LED ( ) ......................44 4.7.2 STATUS LED ( )......................44 4.7.3 LINK/ACT LED ( 4)................45 4.7.4 Disk Access LED ( ) ..................... 45 4.7.5 Optical disk access LED ....................46 Express5800/R120d-2E User’s Guide...
Page 4
Installation........................111 1.20 2.5-inch Hard Disk Drive ........................ 112 1.20.1 Installation........................114 1.20.2 Removal .......................... 116 1.20.3 Replacing a Hard Disk Drive in the RAID System............117 1.21 3.5-inch Hard Disk Drive ........................ 118 1.21.1 Installation........................119 Express5800/R120d-2E User’s Guide...
Page 5
EXPRESSSCOPE ENGINE 3 Network configuration ..............150 EXPRESSBUILDER..........................152 Features of EXPRESSBUILDER ....................152 Starting EXPRESSBUILDER ......................152 Installing Software Components........................ 153 Turning Off the Server..........................154 Chapter 4 Appendix..............................155 Specifications ............................156 PCI Configuration............................158 Express5800/R120d-2E User’s Guide...
Unless otherwise stated, hard disk drives (HDD) described in this document refer to the following. • Hard disk drives (HDD) • Solid state drive (SSD) Removable media Unless otherwise stated, removable media described in this document refer to the following. • USB memory • Flash FDD Express5800/R120d-2E User’s Guide...
• Windows Server 2008 32-bit Edition: Windows Server 2008 x86 *2: Unless otherwise stated, Windows Server 2003 R2 and Windows Server 2003 are collectively referred to as Windows Server 2003. *3: Used as an installation platform only. Express5800/R120d-2E User’s Guide...
Trademarks Trademarks EXPRESSSCOPE are registered trademarks of NEC Corporation. Microsoft, Windows, Windows Server, Windows Vista, and MS-DOS are registered trademarks or trademarks of Microsoft Corporation in the United States and other countries. Intel, Pentium, and Xeon are registered trademarks of Intel Corporation of the United States.
The mark on the electrical and electronic products only applies to the current European Union Member States. Outside the European Union If you wish to dispose of used electrical and electronic products outside the European Union, please contact your local authority and ask for the correct method of disposal. Express5800/R120d-2E User’s Guide...
Page 10
Веществ в электрическом и электронном оборудовании (утверждённого Постановлением №1057 Кабинета Министров Украины) Изделие соответствует требованиям Технического Регламента об Ограничении Использования некоторых Вредных Веществ в электрическом и электронном оборудовании (ТР ОИВВ). Содержание вредных веществ в случаях, не предусмотренных Дополнением №2 ТР ОИВВ: Express5800/R120d-2E User’s Guide...
Page 11
)– не превышает 0,1 % веса вещества или в концентрации до 1000 миллионных частей; полибромбифенолы (PBB) – не превышает 0,1 % веса вещества или в концентрации до 1000 миллионных частей; полибромдифеноловые эфиры (PBDE) – не превышает 0,1 % веса вещества или в концентрации до 1000 миллионных частей. Express5800/R120d-2E User’s Guide...
The contents of this document may change without prior notice. Do not make copies or alter the document content without permission from NEC Corporation. Every effort has been made to ensure the completeness of this document. However, if you have any concerns, or discover errors or omissions, please contact your retailer.
Names and Functions of Parts in this document. Safety precautions Follow the instructions in this document for the safe use of the NEC Express server. This User’s Guide describes hazardous parts of the server, possible hazards, and how to avoid them. Server components with possible danger are indicated with a warning label placed on or around them (or, in some cases, by printing the warnings on the server).
Unplug the power cord of the server. cannot be specifically identified. Make Otherwise, an electric shock or fire may sure to follow the instruction. be caused. Make sure equipment properly grounded. Otherwise, an electric shock or fire may be caused. Express5800/R120d-2E User’s Guide...
Failure to follow this warning may cause an electric shock, a fire, or failure of the server. When such things accidentally enter the server, immediately turn off the power and disconnect the power plug from the outlet. Do not disassemble the server, and contact the store where you purchased the product or your maintenance service company. Express5800/R120d-2E User’s Guide...
For inquiries regarding the installation or wiring of the power supply system, consult with the company that performed the installation or wiring, or the power company that services your area. Express5800/R120d-2E User’s Guide...
• Do not secure the power cord with staples or damaged power cord with a power cord of the equivalents same standard. For information on replacing the power cord, contact the store where you purchased the product or a maintenance service company) Express5800/R120d-2E User’s Guide...
Do not get your fingers caught in the rails When mounting/removing the server onto/from the rack, be careful to avoid getting your fingers caught in the rails or cutting your fingers on the rails. Express5800/R120d-2E User’s Guide...
Use only the specified interface cable. Use only interface cables provided by NEC and locate a proper device and connector before connecting a cable. Using an authorized cable or connecting a cable to an improper destination may cause a short circuit, resulting in a fire.
Keep your hands and hair away from the cooling fan at the rear of the server during operation. Failure to observe this warning may cause your hands or hair to catch in the fan, resulting in personal injury. Express5800/R120d-2E User’s Guide...
If no label is attached or printed on the server, or if there is a label coming off or stained, contact the store where you purchased the product. External view Ex. Express5800/R120d-2E (3.5-inch Drive Model) 243-203025-003-00 Express5800/R120d-2E User’s Guide...
Tape media: Approximately 1 day • For optional devices, we recommend you use our NEC products. Some memory or hard disk drives manufactured by other companies are supported for use with this server, however, you will be charged to repair failure or damage caused by use of such products even within warranty period.
− Optional devices contain electronic components sensitive to static electricity. Avoid failures caused by static electricity when installing or removing any optional devices. Express5800/R120d-2E User’s Guide...
Page 24
Keeping your equipment clean is important not only for the appearance but also for functional and safety reasons. A dusty monitor makes it difficult to see the display contents, so clean it regularly. Take rest breaks When you feel tired, take a break. Light exercise is also recommended. Express5800/R120d-2E User’s Guide...
Verify the condition of your server's accessories. 3. Standard Features Check and maintain the server system by using the functions explained in this section. 4. Names and Functions of Parts This section describes the name of each part contained in this server. Express5800/R120d-2E User’s Guide...
This high performance server is powered by the latest microprocessor "Intel Xeon processor. NEC’s latest technology and architectures realize high-power and high-speed operation that cannot be matched by existing servers. The server is designed with consideration of not only reliability but also expandability, which enables you to use it as a network server.
The chassis serial number plate and maintenance label is located on the server. If the serial number does not match the number on the warranty, you may not be guaranteed against failure even within the warranty period. Contact your sales representative if they do not match. Express5800/R120d-2E User’s Guide...
The security lock that comes with the front bezel (Option of R120d-2E) Management Utilities • NEC ESMPRO • ExpressUpdate • Remote controlling feature (EXPRESSSCOPE Engine 3) • RAID system management utility (Universal RAID Utility) • Hard disk drive monitoring • Power monitoring feature Express5800/R120d-2E User’s Guide...
Page 29
El Torito Bootable CD-ROM (no emulation mode) format supported • Software power-off • Remote power-on feature • AC-Link feature • Remote console feature • Power switch mask • Connector for display unit provided on front panel • Baseboard Management Controller (BMC) conforming to IPMI v2.0 Express5800/R120d-2E User’s Guide...
Page 30
With N8154-46 2.5-inch HDD cage installed. 8 slots for 2.5-inch hard disk drive in standard configuration. With N8154-47 2.5-inch HDD cage (rear) installed. 24 slots for 2.5-inch hard disk drive bay in standard configuration. With N8154-47 2.5-inch HDD cage (rear) installed. 12 slots for 3.5-inch hard disk drive bay in standard configuration. Express5800/R120d-2E User’s Guide...
The hardware components of the server provide operation control/reliability features as shown below. Additionally, NEC ESMPRO Agent, which is provided in EXPRESSBUILDER, enables you to collectively manage the state of your systems. You can also monitor the server states from a PC to manage the network where NEC ESMPRO Manager provided in EXPRESSBUILDER is installed.
3. Standard Features Firmware and Software Version Management Use of NEC ESMPRO Manager and ExpressUpdate Agent allows you to manage versions of firmware and software as well as update them by applying update packages. This function automatically updates multiple modules without stopping the system just by specifying the application of an update package from NEC ESMPRO Manager.
Chapter 1 General Description 4. Names and Functions of Parts Names and Functions of Parts This section describes the names of the server parts. Front View (Front Bezel option: N8146-26F) Express5800/R120d-2E (16x 2.5-inch Drive Model) (3)-1 (3)-3 (3)-2 (3)-4 Front Bezel STATUS LED (green/amber) The cover to protect the front of the server.
Page 34
Chapter 1 General Description 4. Names and Functions of Parts Express5800/R120d-2E (26x 2.5-inch Drive Model) Express5800/R120d-2E (3.5-inch Drive Model) (3)-1 (3)-2 (3)-3 (3)-4 (1) Front Bezel (5) STATUS LED (green/amber) The cover to protect the front of the server. This cover can This LED indicates the server status.
Chapter 1 General Description 4. Names and Functions of Parts Front View (with the Front Bezel Removed) Express5800/R120d-2E (16x 2.5-inch Drive Model) See (3) to (5) on previous page. (10) (11) (12) (13) (14) (15) (16) (17) (9)-1 (9)-3 (9)-5...
Page 36
Chapter 1 General Description 4. Names and Functions of Parts Express5800/R120d-2E (26x 2.5-inch Drive Model) See (3) to (5) on previous page. (14) (13) (11) (12) (10) (9)-0 (9)-2 (9)-4 (9)-6 (9)-8 (9)-10 (9)-12 (9)-14 (9)-16 (9)-18 (9)-20 (9)-22 (15)
Page 37
Chapter 1 General Description 4. Names and Functions of Parts Express5800/R120d-2E (3.5-inch Drive Model) See (3) to (5) on previous page. (14) (13) (11) (12) (15) (9)-0 (9)-3 (9)-6 (9)-9 (9)-1 (9)-4 (9)-7 (9)-10 (10) (9)-2 (9)-5 (9)-8 (9)-11 DISK LED (green/amber)
4. Names and Functions of Parts Rear View (13) (11) (11) (11) (11) (11) (14) (15) (10)-4 (10)-3 (10)-2 (10)-1 (12) With N8154-47 2.5-inch HDD cage (rear) installed.* (16)-12/24 (16)-13/25 *: Express5800/R120d-2E (26x 2.5-inch Drive Model) and Express5800/R120d-2E (3.5-inch Drive Model) only. Express5800/R120d-2E User’s Guide...
Page 39
(10) LAN connectors sequential numbers indicate the corresponding port 1000BASE-T/100BASE-TX/10BASE-T supported numbers. Ethernet connectors Express5800/R120d-2E (26x 2.5-inch Drive Model): Sequential numbers 1 ,2,3 and 4 indicate LAN connectors Port 24,25 1,2,3 and 4, respectively. Express5800/R120d-2E (3.5-inch Drive Model): If Shared BMC LAN feature is enabled in ROM Utility, LAN...
Chapter 1 General Description 4. Names and Functions of Parts Internal View The image below does not show the processor duct. Ex. Express5800/R120d-2E (16x 2.5-inch Drive Model) (8)-1 FAN1F FAN1R FAN2F FAN2R (8)-2 FAN3F FAN3R (8)-3 FAN4F FAN4R FAN5F FAN5R...
While hardware is operating normally, STATUS LED lights green. STATUS LED is off or lights/flashes amber if there is a problem with hardware. The following table lists STATUS LED patterns, their explanation and solution. Tips You can reference error logs to check the causes of failures by using NEC ESMPRO. STATUS LED pattern Explanation Solution −...
This indicates a hard disk drive is being accessed On (amber) This indicates a hard disk drive is failing. Flashing (green and amber This indicates that a hard disk drive is being rebuilt. alternately) Hard disk drive is halted. Express5800/R120d-2E User’s Guide...
• Do not turn off or reboot the server while a hard disk drive is being rebuilt. • Wait at least 90 seconds before installing a hard disk drive after removing one. • Do not replace a hard disk drive while another hard disk drive is being rebuilt. Express5800/R120d-2E User’s Guide...
This LED indicates which network interface is used. The four LAN connectors for data transmission support 1000BASE-T, 100BASE-TX, and 10BASE-T. Management LAN port supports 100BASE-TX and 10BASE-T. SPEED LED pattern Explanation On (amber) Operating with 1000BASE-T On (green) Operating with 100BASE-TX Operating with 10BASE-T Express5800/R120d-2E User’s Guide...
Cold Redundant feature is enabled. On (amber) The power cable is not connected in Connect the power cable. redundant power configuration. Power supply unit is failing. Contact your sales representative. Flashing (amber) Power supply unit is failing. Express5800/R120d-2E User’s Guide...
1. Installing Internal Optional Devices You can skip this section if you did not purchase any optional devices. 2. Installation and Connection You must place the server in an ideal location and connect some cables following this section. Express5800/R120d-2E User’s Guide...
• Use only the devices and cables specified by NEC. You will be charged to repair damages, malfunctions, and failures caused by the use of any devices or cables not specified for use with this server even within the warranty period.
Connecting a charged cable with an I/O device may cause damage to the device. It is recommended to discharge static electricity before connecting a cable by using ionizer or the like. Consult with your sales representative for apparatus to discharge static electricity. Express5800/R120d-2E User’s Guide...
PCI card, additional HDD cage, additional HDD cage(rear), additional/redundant fan unit, optical disk drive Important Do not leave the server open on the rack. If you are going to install a hard disk drive only, go to step 10. Express5800/R120d-2E User’s Guide...
Page 53
Attach the front bezel. Refer to Chapter 2 (1.5 Removing the Front Bezel). This is the end of the installation or removal procedures for internal optional devices. Continue the setup with reference to Chapter 2 (2.2 Connection). Express5800/R120d-2E User’s Guide...
UID switch first. If UID (Unit ID) switch is pressed, UID LED will be on or flash. If it is pressed again, the LED will be off. <Front View> Express5800/R120d-2E (16x 2.5-inch Drive Model) UID switch Express5800/R120d-2E (26x 2.5-inch Drive Model) UID switch Express5800/R120d-2E User’s Guide...
Insert the attached security key into the key slot and turn the key to the front bezel side while pressing it lightly to release the lock. Unlocked Locked Hold the both end of the front bezel carefully, pull it toward you, and remove it. Note Be careful not to press POWER Switch. Express5800/R120d-2E User’s Guide...
Slide the top cover toward the front of the server while pressing the lock button on the cover. Lift off the top cover (front) from the server. Loosen the thumb nut on rear of the server, and slide the top cover (rear) to rear side. Express5800/R120d-2E User’s Guide...
Page 58
Chapter 2 Preparations 1. Installing Internal Optional Devices Lift the top cover (rear) and remove it. Express5800/R120d-2E User’s Guide...
Refer to steps 1 to 6 in Chapter 2 (1.3 Overview of Installation and Removal) for preparations. Remove the duct. Attach the Internal Flash Memory and fix it with the screw provided with this product. 1.7.2 Removal To remove the Internal Flash Memory, reverse the installation procedure. Express5800/R120d-2E User’s Guide...
The TPM Kit once installed cannot be removed. Refer to steps 1 to 6 in Chapter 2 (1.3 Overview of Installation and Removal) for preparations. Remove the duct. Install TPM Kit and secure it by pushing the nylon rivet provided with TPM Kit. Express5800/R120d-2E User’s Guide...
• Do not operate the system until confirming that the additionally installed processor is in normal state. • Make sure to use the processor authorized by NEC. Installing a third-party processor may cause a failure of the processor as well as the motherboard.
Page 62
Put the additional processor on the CPU socket slowly and gently. For easy installation, hold edges of processor with your thumb and index fingers so that the notch is aligned with the key on the CPU socket. Notch Pin mark Pin mark Express5800/R120d-2E User’s Guide...
Page 63
Temporarily tighten the four screws diagonally, then tighten them securely. Make sure that the screw aligns with the screw hole. If not, the screw may damage the motherboard. Note Make sure that the heat sink is properly attached and properly direction. Express5800/R120d-2E User’s Guide...
– All screws are not completely tightened. • Do not move the secured heat sink. Express5800/R120d-2E(16x 2.5 inch Drive Model) only 12. If the processor is additionally installed, you need to install the additional fan unit provided with additional processor. Refer to Chapter 2 (1.16 /Additional/Redundant Fan Unit) for how to install an additional fan unit.
1.10.2 Memory Clock The server supports the memory clock speed of DDR3-800/1066/1333MHz. However, the actual memory clock speed depends on CPU model and memory configuration. The memory clocks of all of buses operate at the same clock speed. Express5800/R120d-2E User’s Guide...
If using a Windows OS, refer to Chapter 1 (7.1 Specifying Memory Dump Settings (Debug Information)) in "Installation Guide (Windows)". For other OS, consult the manual provided with the operation system or contact the store where you purchased it or your maintenance service company. Express5800/R120d-2E User’s Guide...
Note When removing a defective DIMM, check error messages displayed at POST or NEC ESMPRO and check the DIMM socket where the defective DIMM is installed. Take the steps below after replacing or removing DIMMs. Confirm that no error messages are displayed on POST. If any error message is displayed, refer to Chapter 3 (1.
Run SETUP again, and check if the status of additionally installed DIMMs shows "Mirror". • Installation order depends on CPU configuration. See the figure below. The mirroring cannot be configured in the following case: • Memory mirroring within a specific memory channel Express5800/R120d-2E User’s Guide...
Page 71
• LockStep between memory channels of different memory controllers (CPU) • LockStep within the same memory channel Notes on Configuring LockStep If you install or remove DIMMs that unable to configure Memory LockStep, parameter for [Memory RAS Mode] is changed from "LockStep" to "Independent". Express5800/R120d-2E User’s Guide...
Page 72
The following Memory sparing cannot be configured. • A DIMM of different capacity is installed. Notes on Configuring Memory Sparing If you install or remove DIMMs that unable to configure Memory Sparing, parameter for [Memory RAS Mode] is changed from "Spared" to "Independent". Express5800/R120d-2E User’s Guide...
Remove the riser card from the slot in which you are going to install an extra battery. Refer to Chapter 2 (1.13 PCI Card) . Connect the cable to the additional battery. When connecting the cable, orient the cable so that its marking will fit the connector. Remove the battery bracket from the duct. Battery bracket Express5800/R120d-2E User’s Guide...
Page 74
For how to install riser card, refer to Chapter 2 (1.13 PCI Card). 10. Attach the duct which extra battery is installed. 1.11.3 Removal For removing the extra battery for the RAID Controller, reverse the installation procedure. Express5800/R120d-2E User’s Guide...
Backup File Device The 16x 2.5-inch Drive Model has one slot for installing a backup file device such as a magnetic tape drive. Important Install only a backup file device specified by NEC. Backup file device bay 1.12.1 Installation (USB File Devices) Refer to Chapter 2 (1.3 Overview of Installation and Removal) for preparations.
Page 76
Connect the power cable and interface cable to the backup file device. Connect the power cable provided with the server and separately-priced USB cable (K410-194/195(00)) to the backup file device. Power cable USB cable Express5800/R120d-2E User’s Guide...
Page 77
Refer to the manual that comes with the backup file device. 1.12.2 Removal Remove the backup file device in reverse order of the installation steps. Important To maintain the cooling effect in the server, install the blank cover in the vacant slot. Express5800/R120d-2E User’s Guide...
For a SCSI Controller, RAID Controller, LAN card (network boot), or Fibre Channel controller, if no hard disk drive on which an OS is installed is connected, set the option ROM for that slot to Disabled. Refer to Chapter 2 (1. System BIOS) in "Maintenance Guide" for how to specify it. Express5800/R120d-2E User’s Guide...
− − N8190-154 Fibre Channel Controller (2ch) (8Gbps/Optical) [PCI Express 3.0(x8)] − N8104-138 1000BASE-T Adapter For additional LAN (1ch) port. [PCI Express 2.0(x1)] Teaming (AFT/SFT/ALB) and bonding with onboard LAN (including additional riser card) N8104-138/132/133 is supported. Express5800/R120d-2E User’s Guide...
Page 80
The card performance described in the parentheses after the Product name indicates the maximum operation performance of the card. When the operation performance of a PCI card is higher than the PCI slot on the server, the PCI card operates with the performance of the PCI slot on the server. Express5800/R120d-2E User’s Guide...
Confirm the installation position with the reference to the table in (1.13.2 Supported cards and available slots). Remove the screw, and remove RAID Screw Controller bracket from the rise card. RAID Controlller bracket Note Keep the slot cover for future use. Express5800/R120d-2E User’s Guide...
Page 82
• If you have trouble in installing the card, remove the card once and try again. If you apply excessive pressure on the card, a PCI card or riser card might break. Tips Connect a cable between connector on HDD backplane and RAID card before installing the riser card to the server. Express5800/R120d-2E User’s Guide...
Page 83
In that case, configure the boot priority in the Boot menu of the BIOS Setup utility. For details about the Boot menu, refer to Chapter 2 (1.2.5 Boot) in "Maintenance Guide". Express5800/R120d-2E User’s Guide...
Page 84
Confirm the installation position with the reference to the table in (1.13.2 Supported cards and available slots). Remove the blank cover from the rise card (common to PCI slots #1B to 3B, 1C, and 2C) . ① ② Note Keep the blank cover for future use. Express5800/R120d-2E User’s Guide...
Page 85
Continue to install or remove internal optional devices, mount and connect the server, and turn it on. Make sure that no error messages are displayed on POST screen. For details on POST error messages, refer to Chapter 3 (1. POST Error Message) in "Maintenance Guide". Express5800/R120d-2E User’s Guide...
Page 86
If needed, run SETUP utility, and then specify the boot order from the Boot menu. For details about the Boot menu, refer to Chapter 2 (1. System BIOS) in "Maintenance Guide". If using the server while the card is removed, attach the slot cover that comes with the riser card. Express5800/R120d-2E User’s Guide...
Refer to steps 1 to 6 in Chapter 2 (1.3 Overview of Installation and Removal) for preparations. Remove the six screws from protective cover, and remove the protective cover. Remove the blank cover of 2.5-inch HDD cage bay by pulling it toward you. Note Keep the removed blank cover for future use. Express5800/R120d-2E User’s Guide...
Page 88
Mount HDD Cage and join the projection of the server (four places) to the hole on back of HDD Cage (four places). The projection of the server (four places) The hole on back of HDD Cage (four places) While pressing down on the HDD cage, move it toward the rear of the server to fix. Express5800/R120d-2E User’s Guide...
Page 89
Insert the edge of HDD Cage to edge of chassis carefully, as shown in the following figure. The edge of HDD Cage is not correctly inserted The edge of HDD cage is correctly inserted to edge of chassis to edge of chassis Express5800/R120d-2E User’s Guide...
Page 90
Secure the protective cover with six screws you have removed in Step 2. Disconnect SAS/SATA cable from the factory-installed HDD cage. Install expander board to Expansion Bay and secure it with five screws provided with additional HDD cage. Express5800/R120d-2E User’s Guide...
Page 91
Connect the SAS/SATA cable you removed in Step 7. (or provided with the server) to Expander Board. SAS/SATA cable factory-installed additional Backplane Backplane Board Board Expander Board RAID Controller SAS 1(Port 0-3 or Port 1-4 ) RAID Controller SAS 2(Port 4-7 or Port 5-8 ) Express5800/R120d-2E User’s Guide...
Page 92
Attach the ID label to the front face of chassis. 1.14.2 Removal To remove an additional HDD cage, reverse the installation procedure. Important To maintain the cooling effect in the server, install the blank cover in the vacant slot. Express5800/R120d-2E User’s Guide...
Refer to steps 1 to 6 in Chapter 2 (1.3 Overview of Installation and Removal) for preparations. Remove the two screws and remove the blank cover from 2.5-inch HDD cage bay. Screws Note Keep the removed blank cover for future use. Express5800/R120d-2E User’s Guide...
Page 94
Then fix them by the two screws removed by the Step 2. Screws Connect the Power cable, SGPIO cable and SAS/SATA cable provided with additional HDD cage. < Express5800/R120d-2E(26x 2.5-inch Drive Model> SAS_B HDD Backplane Board Expander Board...
Page 95
Chapter 2 Preparations 1. Installing Internal Optional Devices < Express5800/R120d-2E(3.5-inch Drive Model)> SAS_B SAS_A HDD Backplane Board Connect to MB(Additional HDD Cage (Rear) Power connector) SAS_A SAS/SATA cable SAS_B SGPIO cable Upside Power cable Downside HDD cage (rear) Install the two fan units to the fan cage.
Page 96
After putting the catches (two places on the bottom of the fan cage) into the notch cuts of the server, install the fan cage by adjusting the positioning pins to the positioning on the HDD cage. Positioning Notch Cuts Note Check that the fan cage is firmly fixed Express5800/R120d-2E User’s Guide...
Page 97
Connect the cables of the fan units to the sockets(FAN6R/FAN7R) on the motherboard FAN6R FAN7R 1.15.2 Removal To remove an additional HDD cage (rear), reverse the installation procedure. Important To maintain the cooling effect in the server, install the blank cover in the vacant slot. Express5800/R120d-2E User’s Guide...
The server can work with redundant cooling fan system by adding an optional fan unit. The figure below shows the slot numbers assigned to the slots of standard cooling fans and optional cooling fans. Express5800/R120d-2E (16x 2.5-inch Drive Model) Standard FANs Redandunt FANs...
In 1-CPU configuration: Install redundant fan units in slots FAN 1F to 3F, and 5F. In 2-CPU configuration: Install redundant fan units in slots FAN 1F to 5F. Insert the fan unit straight into the additional fan slot until it locks with clicking sound. Express5800/R120d-2E User’s Guide...
Be sure to observe the following precautions to use the server safely. Failure to observe the precautions may cause burns, injury, and property damage. For details, refer to Safety precautions in Precautions for Use. • Pay attention to electric hazard. Express5800/R120d-2E User’s Guide...
Remove a single screw from the cage, and Dummy cover remove the bracket and dummy cover. Bracket Important Keep the screw and dummy tray in the optical disk drive for future use. Install the optical disk drive to the cage. Express5800/R120d-2E User’s Guide...
Page 103
Connect the cable to optical disk drive. 1.17.2 Removal To remove an optical disk drive, reverse the installation procedure above. Important To maintain the cooling effect in the server, install the dummy cover in the vacant slot. Express5800/R120d-2E User’s Guide...
• When connecting a RAID Controller, set the boot priority to 8th or higher in the Boot menu of the BIOS Setup utility. If the setting is 9th or lower, the configuration menu for RAID Controllers cannot be launched. Tips When using SAS Hard Disk Drives, RAID Controller must be connected. Express5800/R120d-2E User’s Guide...
<16x 2.5-inch Drive Model : When using onboard RAID controller (1 to 4 drives)> SAS/SATA Cable SGPIO Cable HDD Backplane Board MB (HDD Backplane Board Signal connector) MB (SATA Connector) MotherBoard HDD Backplane Board Hard Disk Drive Port 0 Port 1 SATA0_3 SAS0_3 Port 2 Port 3 Express5800/R120d-2E User’s Guide...
Page 106
HDD Backplane Board Hard Disk Drive RAID Controller Port 0 Port 1 SAS 1 SAS0_3 (Port 0-3 or Port1-4) Port 2 Port 3 Port 4 Port 5 SAS 2 SAS4_7 (Port 4-7 or Port5-8) Port 6 Port 7 Express5800/R120d-2E User’s Guide...
Page 107
Port 6 Port 7 Port 8 HDD BackPlane Port 9 SAS0_3H2 Board(2) SAS0_3 Port 10 SAS 2 Port 11 (Port 4-7 or SAS4_7R Port 5-8) Port 12 HDD BackPlane Port 13 SAS4_7H2 Board(2) SAS4_7 Port 14 Port 15 Express5800/R120d-2E User’s Guide...
Page 108
Hard Disk Drive RAID Controller SAS 1 SAS0_3 (Port 0~3 or Port 1~4) Port 0~23 SAS 2 SAS4_7 (Port 4~7 or Port 5~8) HDD Backplane Expander Board Hard Disk Drive Board(Rear) SAS_A SAS_A Port 24 SAS_B SAS_B Port 25 Express5800/R120d-2E User’s Guide...
Page 109
SAS0_3 (Port 0~3 or Port 1~4) Port 0~11 SAS 2 SAS4_7 (Port 4~7 or Port 5~8) HDD Backplane Board HDD Backplane Board(Rear) Hard Disk Drive SAS_A SAS_A Port 12 SAS_B SAS_B Port 13 SAS_C No Use SAS_D Express5800/R120d-2E User’s Guide...
RAID Controller (N8103-149/150/151). • Do not change the RAID System mode to hibernate. Important • Build a Disk Array in the RAID System using Hard Disk Drives that have the same specifications (capacity, rotational speed, and standard). Express5800/R120d-2E User’s Guide...
Put the top cover (front) straight on the server chassis so that it can be surely engaged with the chassis frame. Slide the top cover (front) toward the rear of the server, until it is locked with clicking sound. Express5800/R120d-2E User’s Guide...
Important Use hard disk drives specified by NEC. Installing a third-party hard disk drive might cause a failure of the server and it. Note the following precautions to install hard disk drives.
• Keep the dummy trays for future use. Important • Dummy trays are intended to increase the cooling effect inside the server. Keep the dummy trays installed in slots where Hard Disk Drives are not installed. Unlock the handle of the drive carrier. Express5800/R120d-2E User’s Guide...
Page 115
Turn on the server, run BIOS SETUP utility, and then specify the boot order from the Boot menu. For details about the Boot menu, refer to Chapter 2 (1.2.5 Boot) in "Maintenance Guide". This process is required because the saved boot order is cleared when you add a Hard Disk Drive. Express5800/R120d-2E User’s Guide...
If you transfer or dispose of the removed hard disk drive, refer to Chapter 1 (1. Transfer, Movement, and Disposal) in “Maintenance Guide” to erase data. Important NEC assumes no liability for data leakage should the product be transferred to a third party without erasing the data. Note If you have to remove a disk due to a hard disk drive failure, check the slot with its DISK LED lit in amber.
Leave an interval of at least 90 seconds between a Hard Disk Drive removal and a Hard Disk Drive installation. • Do not replace a disk during the auto rebuilding of another Hard Disk Drive (during an auto rebuild, the DISK LED on the Hard Disk Drive flashes green and amber alternately). Express5800/R120d-2E User’s Guide...
Important Use hard disk drives specified by NEC. Installing a third-party hard disk drive might cause a failure of the server and it. Note the following precautions to install hard disk drives.
Install a Hard Disk Drive by using the following procedure. Follow the same installation procedure for other slots. Note Use hard disk drives specified by NEC. Installing a third-party hard disk drive might cause a failure of the server and it. Refer to Chapter 2 (1.3 Overview of Installation and Removal) for preparations.
Page 120
Turn on the server, run SETUP utility, and then specify the boot order from the Boot menu. For details about the Boot menu, refer to Chapter 2 (1.2.5 Boot) in "Maintenance Guide". Tips The saved boot order is cleared when a hard disk drive is added. Express5800/R120d-2E User’s Guide...
If you transfer or dispose of the removed hard disk drive, refer to Chapter 1 (1. Transfer, Movement, and Disposal) in “Maintenance Guide” to erase data. Important NEC assumes no liability for data leakage should the product be transferred to a third party without erasing the data. Note If you have to remove a disk due to a hard disk drive failure, check the slot with its DISK LED lit in amber.
Refer to Chapter 2 (1. System BIOS) in "Maintenance Guide", change parameters as shown below, save the settings and exit from SETUP. Server → Power Control Configuration → Cold Redundant Mode → Enabled Run SETUP again, and check if the status of Cold Redundant Mode shows Enabled in Server menu. Express5800/R120d-2E User’s Guide...
Refer to steps 1 to 4 in Chapter 2 (1.3 Overview of Installation and Removal) for preparations. Remove the blank cover. Important Keep the removed blank cover for future use. Insert the power supply unit.until it is locked with clicking sound. Express5800/R120d-2E User’s Guide...
Page 124
Refer to Chapter 2 (5. Troubleshooting) of the Maintenance Guide for details on the error messages. If the AC POWER LEDs are off, reinstall the power supply units. If the same error message still appears, contact your service representative. Express5800/R120d-2E User’s Guide...
To maintain the cooling effect in the server, install the blank cover in the vacant slot. Install the new power supply unit taking steps 3 to 7 of "Installation", and confirm that the power supply unit is installed normally. Express5800/R120d-2E User’s Guide...
1. Installing Internal Optional Devices 1.23 Installing Front Bezel When installing Front Bezel, engage catches of front bezel with those on mounting ear. After installing Front Bezel, lock it with Bezel Lock Key. Important Be careful not to press POWER Switch. Express5800/R120d-2E User’s Guide...
• Do not leave more than one device being pulled out from the rack. • Do not provide the wiring for the server to exceed the rating of the power supply. • Do not use in the environment where corrosive gas is generated. Express5800/R120d-2E User’s Guide...
Page 128
If you must install the server close to such equipment, have your maintenance service company separate power cables or install noise filter. • Environment where operation of the server is not guaranteed Express5800/R120d-2E User’s Guide...
Review airflow in the rack and room and take sufficient measures so that the internal temperature will not exceed the operational temperature during operation. Air enters the server from the front and exits from the rear. Express5800/R120d-2E User’s Guide...
Page 130
Chapter 2 Preparations 2. Installation and Connection Installation This server can be mounted to a rack made by NEC or other companies. Mount the server to a rack in the following procedure. Preparation for mounting • Checking rails • Installing inner and outer rails Important Rail for left side has different shape from that for right side.
Page 131
• Do not attempt to lift the server with a single person. • Do not drop. • Do not leave the server being pulled out. • Do not install with the cover removed. • Do not get your fingers caught. Express5800/R120d-2E User’s Guide...
Page 132
When the server is pushed into the rack and is locked, push the server to the end while pulling the release levers (blue) on both sides of the server. Push the server until its lock on front Release lever panel clicks. Express5800/R120d-2E User’s Guide...
Page 133
• Do not apply pressure on the server from top when it is being pulled out. Doing so cause the server to drop, which is dangerous. • Be careful not to get your finger caught in rails. Express5800/R120d-2E User’s Guide...
Page 134
Push the unlock lever on outer rail to the direction shown by arrow to house the slide rail. Unlock lever Locking mechanism While pressing the lever on outer rail, push the outer rail toward inside of the rack, then remove it. Front View Rear view Express5800/R120d-2E User’s Guide...
• Insert the power plug into the outlet as far as it goes. • Use only the specified power cord • Do not connect or disconnect the interface cable with the power plugged in the outlet. • Use only the specified interface cable Express5800/R120d-2E User’s Guide...
Page 136
Chapter 2 Preparations 2. Installation and Connection Display unit*1 (1) Front View USB device 16x 2.5-inch Drive Model *1 Either one can be connected. USB device 26x 2.5-inch Drive Model USB device 3.5-inch Drive Model Express5800/R120d-2E User’s Guide...
Page 137
*2 Connect the power cord to circuit breaker of up to 15 A. Note If you connect a card to a line, use the card which you have applied for with the certification authority. Tips A leased line cannot be directly connected to the serial port connector. Express5800/R120d-2E User’s Guide...
Page 138
If you connect an external USB DVD-ROM drive to a USB connector at the front of the server, do not connect any other device to the adjacent USB port. See the figure below. 26x 2.5-inch Drive Model, 16x 2.5-inch Drive Model 3.5-inch Drive Model Express5800/R120d-2E User’s Guide...
To change the settings, select Server and then AC-LINK in the BIOS setup utility, and change the displayed parameters. Select Power On to perform automatic operations by using the UPS. For details, refer to Chapter 2 (1.2.4 Server) in "Maintenance Guide". Express5800/R120d-2E User’s Guide...
EXPRESSBUILDER helps you to install Windows and maintain the server. 5. Installing Software Components You can install Windows and bundled software by following the instructions in "Installation Guide (Windows)". 6. Turning off the Server Turn off power when not using the server. Express5800/R120d-2E User’s Guide...
Press the POWER switch at the front of the server. The POWER LED is turned on green and after a while, the logo appears on the display. Important Do not connect or disconnect USB device while POST is running. Express5800/R120d-2E (16x 2.5-inch Drive Model) POWER switch Express5800/R120d-2E User’s Guide...
Page 142
Chapter 3 Setup 1. Turning on the Server Express5800/R120d-2E (26x 2.5-inch Drive Model) POWER switch Express5800/R120d-2E (3.5-inch Drive Model) POWER switch While the logo is being displayed, the self-diagnostic program (POST) runs and diagnoses the hardware. For details, refer to Chapter 3 (1.1.1 POST sequence).
By pressing the designated function key following messages, you can call the functions below upon completion of POST. <F2> key: Run BIOS Setup Utility (SETUP). For information on the SETUP, refer to Chapter 2 (1. System BIOS) in "Maintenance Guide". Express5800/R120d-2E User’s Guide...
Chapter 3 (1. POST Error Message) in "Maintenance Guide". Important Take notes on the messages displayed before consulting with your maintenance service company. Alarm messages are useful information for maintenance. Express5800/R120d-2E User’s Guide...
Press <F2> SETUP, <F3> Internal Flash Memory, <F4> ROM Utility, <F12> Network If you press the <F2> key at this time, SETUP runs and displays the Main menu upon completion of POST. (You can also press the <F2> key while the NEC logo appears to display the Main menu.) Important If password is set, you will be prompted to enter password at next startup of SETUP.
Quit without saving? [Yes] <F1> key Press this key to display help information. If you need help using the SETUP, press this key. Press the <Esc> key to go back to the original screen. Express5800/R120d-2E User’s Guide...
Page 147
(This might be different from the parameters configured before shipment.) Load Setup Defaults? [Yes] <F4> key If you press this key, the following window appears. If you select Yes, the parameter you configured is saved and SETUP closes. Save configuration and exit? [Yes] Express5800/R120d-2E User’s Guide...
If it is turned off by using Configuration → AC-LINK → Last POWER switch, leave it OFF even when UPS supplies State power. Server → Power Control Keep the power OFF even Configuration → AC-LINK → Stay off when UPS supplies power. Express5800/R120d-2E User’s Guide...
Page 149
If you wish to exit without saving the changed parameters, select Save & Exit Discard Changes and then and Exit. Or if you wish to restore the setting to default values, select Save & Exit Load Setup Defaults. and then (The default value might be different from the factory setting.) Express5800/R120d-2E User’s Guide...
If you press the <F4> key at this time, ROM utility starts upon completion of POST. You can also press the <F4> key while the NEC logo is being displayed to open the Off-line TOOL MENU screen. The keyboard selection screen appears. Select your keyboard type.
Page 151
Connect the LAN cable to the management LAN connector in order to connect to the network. It will be available for use if you access EXPRESSSCOPE Engine 3 via Web browser from PC for management according to the setting. Express5800/R120d-2E User’s Guide...
To use this feature, select Os (Windows reinstallation) installation in the menu after boot. Storage of software* Stores various bundled software (such as NEC ESMPRO Agent). Maintenance Diagnoses your server system. To use this feature, select Tool menu in the menu after boot.
Shut down the OS. The server automatically turns off after the OS shuts down. Confirm that POWER LED is OFF. Turn off peripheral devices. Tips Hibernate function of Windows Server cannot be used. Do not set Hibernate at Windows shutdown. Express5800/R120d-2E User’s Guide...
Operating: 10 to 40°C*4, Storage: -10 to 55°C Environmental requirements Humidity Operating: 20 to 80%, Storage: 20 to 80% (No condensation either when operating or when stored) EXPRESSBUILDER(NEC ESMPRO Manager(Windows), NEC ESMPRO Agent,User's Guide(electronic document) Main accessories included), Getting Started, Notes on Use, one-touch rack rail...
Page 157
Operating: 10 to 40°C *4, Storage: -10 to 55°C Operating: 20 to 80%, Storage: 20 to 80% Environmental requirements Humidity (No condensation either when operating or when stored) EXPRESSBUILDER(NEC ESMPRO Manager(Windows), NEC ESMPRO Agent,User's Guide(electronic document) Main accessories included), Getting Started, Notes on Use, one-touch rack rail...
Onboard VGA controller PCI board installed in slot PCI1C PCI board installed in slot PCI2C Onboard LAN Correspondence between device numbers and function numbers of onboard LAN is as shown below: Device number Function number Onboard LAN (Device#) (Function#) Express5800/R120d-2E User’s Guide...