Refer to the LYNX Touch Series Installation and Setup Guide P/N 800-10614 or later for detailed information on programming the system. The Installation and Setup Guide contains full descriptions for all data fields. LYNX Touch SIA is not intended for UL985 Household Fire applications unless a 24-hour backup battery (P/N LYNXRCHKIT-SHA) is installed.
You may find it convenient to adjust the volume setting before entering the Programming Mode. This will allow you to clearly hear feedback announcements or system beeps. 1. Power up the LYNX Touch SIA control, when the Home Screen appears, select “More”. 2. Select “Tools”. The system displays a virtual keypad.
Screen Display Function & Programming Options DATA FIELDS Note: If applicable, preprogrammed defaults for the LYNX Touch SIA Control are shown on the screen display. Change Installer Code Installer Code Installer Code Enter 4 digits [The defaulted Installer Code is 4112]...
Page 5
Screen Display Function & Programming Options Remote Access Serial Remote Access Serial Enabled Disabled Disabled Note: If the “Remote Access Serial” option is enabled, you will be prompted to select a “Multi Mode Serial”. Multi Mode Serial Multi Mode Serial Enhanced Reports Disabled Disabled...
Screen Display Function & Programming Options Program Communications Communicator Program the following options: Communicator Communications Path City ID CS ID Sub ID 5000-100-132-V0 Supervision Old Alarm Time Remote Acc. Comm. Multi Mode Comm. GSM Fault Time OR IP Fault Time Communications Path Communications Path None...
Screen Display Function & Programming Options Subnet Mask Subnet Mask Enter 4 part address 255.255.255.255 Gateway IP Address Gateway IP Address Enter 4 part address 255.255.255.255 DNS Server Address DNS Server IP Address Enter 4 part address 255.255.255.255 Program Zones Zones Zones Select from the following zone options:...
Screen Display Function & Programming Options Response Type Response Type Choose from the following options (dependant upon the Device Type): Not Used Not Used Arm Stay Fire No Verification Entry Exit 1 Disarm Monitor Entry Exit 2 Silent Burglary Trouble Interior Follower Resident Response Arm Away...
Screen Display Function & Programming Options Button Key * Zn * Button Key * - Zone * Enter a function for each button key from the following options: Disarm Arm Away Arm Stay No Response 24 Hour Silent 24 Hour Audible 24 Hour Auxiliary Silent Burglary Fire No Verification...
Page 10
Screen Display Function & Programming Options Report Tests Report Tests Always Enabled (not selectable) Enabled Secondary Central Station Information Secondary CS Info Phone Type Communicator Type Phone Type Phone Type None None Contact Id: 4 Digit Contact Id: 10 Digit Note: If SIA, Contact Id: 4 Digit or Contact Id: 10 Digit is selected, the Phone Number and Account Number options will be displayed.
Page 11
Screen Display Function & Programming Options Phone Number Phone Type Enter the Follow Me Phone Number None Report All Report All Press to Report All Press to Report All Report All Set Report Alarms Report Alarms Disabled Disabled Enabled Report Troubles Report Troubles Disabled Disabled...
Screen Display Function & Programming Options Program Sounder Sounder Sounder Choose from the following options: Burglary Alarm Sound Burglary Bell Timeout Fire Bell Timeout Arm Confirm Alarm Options Burglary Alarm Sound Burglary Alarm Sound Burglary Bell Timeout Burglary Bell Timeout 4 Minutes 4 Minutes 8 Minutes...
Page 15
Screen Display Function & Programming Options Exit Delay Exit Delay 45 Seconds 60 Seconds 60 Seconds 90 Seconds 2 Minutes Backlight Timeout Backlight Timeout 30 Seconds Quick Arm Quick Arm Quick Exit Quick Exit Restart Exit Time Restart Exit Time Force Bypass Force Bypass Exit Warning...
Screen Display Function & Programming Options Program the Z-Wave Module Z-Wave Z - Wave Note: This procedure must be completed any time that the panel has been defaulted or updated. 5100-100-067-V0 Z-Wave Z-Wave Select from the following options: Enabled-Installed Telephone Enabled –...
Zone Programming Worksheet Fill in the required data on this worksheet, then follow the programming procedure. See Explanation of Zone Assignment Table Headings (defaults shown are for Table 1) Zone Loop Device Response Transmitter Zone Type Type Report Chime Supervision Serial Number Descriptor End of Line...
Zone Programming Worksheet Zone Loop Device Response Transmitter Zone Type Type Report Chime Supervision Serial Number Descriptor 4 Button (Key) Arm Away Button 4 Button (Key) Disarm Button 4 Button (Key) Arm Stay Button 4 Button (Key) No Response Button 4 Button (Key) Arm Away Button...
5800 Series Transmitter Loop Numbers LOOP 1 LOOP 1 (LOW (LOW SENSITIVITY SENSITIVITY LOOP LOOP 2 LOOP 2 (HIGH (HIGH LOOP 1 SENSITIVITY) SENSITIVITY) LOOP LOOP 3 (TEMP) LOOP 3 (TEMP) LOOP 4 (TAMPER) LOOP 4 (TAMPER) 5 8 0 0 R L 5 8 0 0 C O 5 8 0 0 M i c r a 5 8 0 0 P I R - R E S...
Programming Default Tables Program Function Table 1 Table 2 Table 3 Table 4 4112 4112 4112 4112 Installer Code System Type RF Jam Disabled Disabled Disabled Disabled Speaker Phone Enabled Enabled Enabled Enabled Two Way Voice Disabled Disabled Disabled Disabled RF House Code Phone Notification Disabled...
Page 21
Program Function Table 1 Table 2 Table 3 Table 4 Follow Me Phone 1 Phone Type None None None None Phone Number Blank Blank Blank Blank Report All Press To Report All Press To Report All Press To Report All Press To Report All Report Alarms Disabled...
Page 22
Program Function Table 1 Table 2 Table 3 Table 4 Display Alarm Cancel Display Exit Time Cross Zone Delay None None None None Cross Zone 1 Disabled Disabled Disabled Disabled Cross Zone 2 Disabled Disabled Disabled Disabled Z-Wave Z-Wave Enabled Enabled Enabled Enabled...