S E R V I C E 2007-12 O0707903 531 30 97-18 420GN 2000 Watt Portable Generator Operator’s Manual Manual No. 203861GS Revision A (09/19/2007)
Page 2
Thank you for purchasing this quality-built Husqvarna generator. We are pleased that you’ve placed your confidence in the Husqvarna brand. When operated and maintained according to the instructions in this manual, your Husqvarna generator will provide many years of dependable service.
Hazard Symbols and Meanings A - Explosion F - Hot Surface B - Fire G - Flying Objects C - Electric Shock H - Moving Parts D - Toxic Fumes J - Read Manual E - Kickback www.usa.husqvarna.com...
Page 5
DANGER Storage batteries give off explosive hydrogen gas during recharging. Hydrogen gas stays near battery for a long time after battery has been charged. Slightest spark will ignite hydrogen and cause explosion. You can be blinded or severely injured. Battery electrolyte fluid contains acid and is extremely caustic.
Page 6
• DO NOT insert any objects through cooling slots. • If connected devices overheat, turn them off and disconnect them from generator. • Shut off generator if: -electrical output is lost; -equipment sparks, smokes, or emits flames; -unit vibrates excessively. www.usa.husqvarna.com...
Assembly Your generator requires some assembly and is ready for use after it has been properly serviced with the recommended fuel and oil. If you have any problems with the assembly of your generator, please call the generator helpline at (877) 224-0458. If calling for assistance, please have the model, revision, and serial number from the data tag available.
Ensure exhaust gas is kept away from any windows, doors, ventilation intakes, or other openings that can allow exhaust gas to collect in a confined area. Prevailing winds and air currents should be taken into consideration when positioning generator. www.usa.husqvarna.com...
Features and Controls Read this Operator’s Manual and safety rules before operating your generator. Compare the illustrations with your generator, to familiarize yourself with the locations of various controls and adjustments. Save this manual for future reference. A - Fuel Tank — Capacity of 1.32 U.S. gallons (5.0 L). B - Circuit Breaker (AC) —...
These receptacles can not recharge 6 Volt batteries and can not be used to crank an engine having a discharged battery. See Charging a Battery before attempting to recharge a battery. www.usa.husqvarna.com...
Operation Starting the Engine Disconnect all electrical loads from the generator. Use the following start instructions: 1. Make sure unit is on a level surface. IMPORTANT: Failure to start and operate the unit on a level surface will cause the unit not to start or shut down during operation.
3. Use SAE 5W-30 oil (synthetic preferred, see engine operator’s manual). 4. Check oil level daily or after every eight (8) hours of operation. 5. Maintain generator following maintenance schedule in engine operator’s manual. 6. Shelter unit from elements. www.usa.husqvarna.com...
Page 13
Creating a Temporary Shelter 1. In an emergency, use the original shipping carton. 2. Cut off top carton flaps and one long side of carton to expose muffler side of unit. If required, tape up other sides of carton to fit over generator as shown. Wind NOTE: If required, remove wheel kit to fit carton over generator as shown.
Maintenance General Recommendations Regular maintenance will improve the performance and extend the life of the generator. See an authorized dealer for service. The generator’s warranty does not cover items that have been subjected to operator abuse or negligence. To receive full value from the warranty, the operator must maintain the generator as instructed in this manual and the engine operator’s manual.
WARNING Storage covers can be flammable. • DO NOT place a storage cover over a hot generator. • Let equipment cool for a sufficient time before placing the cover on the equipment. 4. Store generator in clean, dry area. www.usa.husqvarna.com...
Troubleshooting Problem Cause 1. One of the circuit breakers is open. 2. Fault in generator. Engine is running, but no AC 3. Poor connection or defective cord set. output is available. 4. Connected device is bad. 1. Short circuit in a connected load. 2.
Effective February 1, 2006 replaces all undated Warranties and all Warranties dated before February 1, 2006 “Husqvarna® is a registered trademark of Husqvarna AB and is used under license to Briggs & Stratton Power Products. Briggs & Stratton Power Products Group, LLC will repair or replace, free of charge, any part(s) of the portable generator that is defective in material or workmanship or both.