  • Page 1 Operating and installation instructions...
  • Page 2 Fig. 1 Abb. 1 ELECTRO...
  • Page 3: Operating Modes

    Instructions for use: Operating modes Circulating-air mode: Exhaust-air mode: An activated carbon filter must be fitted The extractor-hood fan extracts the for this operating mode (see Filters and kitchen vapours and conveys them maintenance). through the grease filter into the atmosphere.
  • Page 4: Before Using For The First Time

    Before using for the first time Setting the saturation indicator Important notes: If it becomes necessary to change the operating mode (exhaust-air/recirculating The Instructions for Use apply to several mode), the saturation indicator for the filters versions of this appliance. Accordingly, must also be altered (see Installation you may find descriptions of individual Instructions).
  • Page 5 Before using for the first time Safety instructions Do not flambé food directly under the Never allow children to play with the extractor hood. appliance. Risk of grease filter catching fire due Do not let adults or children operate the to flames.
  • Page 6: Operating Procedure

    Operating procedure Setting the required fan speed: The most effective method of removing vapours produced during cooking is to: Press the + button. The fan speed is increased by one step. Switch the ventilator ON as soon as you begin cooking. Press the –...
  • Page 7: Filters And Maintenance

    Filters and maintenance Grease filters: Removing and inserting the metal grease filter: Metal filters are used to trap the greasy Warning: The halogen bulbs must be element of the vapours that develop switched off and cool. during cooking. 1. Pull the grease filter forward carefully. The filter mats are made from non- At the same time take hold of the combustible metal.
  • Page 8 Filters and maintenance Activated carbon filter: Installation and removal: Warning: The halogen bulbs must be For neutralizing odours in recirculating switched off and cool. mode. 1. Remove the metal filter Caution: (see "Removing and inserting the metal As the filter becomes more and more grease filter").
  • Page 9: Cleaning And Care

    Cleaning and care Replacing the light bulbs Isolate the extractor hood by pulling out 1. Switch off the extractor hood and pull the mains plug or switching off the fuse. out the mains plug or switch off the electricity supply at the fuse box. Do not clean the extractor hood with abrasive sponges or with cleaning agents When switched on, the halogen bulbs...
  • Page 10: Installation Instructions

    Installation Instructions: Important information Additional information concerning gas Old appliances are not worthless cookers: rubbish. Valuable raw materials can be reclaimed by recycling old appliances. When installing gas hotplates, comply Before disposing of your old appliance, with the relevant national statutory render it unusable.
  • Page 11: Prior To Installation

    Prior to installation Exhaust-air mode Exhaust-air min. 830 max. 1144 The exhaust air is discharged upwards through a ventilation shaft or directly through the outside wall into the open. This can be achieved if combustion air can flow through non-lockable openings, e.g. in Exhaust air should neither be directed doors, windows and via the air- into a smoke or exhaust flue that is...
  • Page 12: Circulating-Air Mode

    Prior to installation For optimum extractor hood efficiency: Connecting a l 150 mm exhaust-air pipe: Short, smooth air exhaust pipe. Mount the pipe As few bends in the pipe as possible. directly onto the Diameter of pipe to be as large as air outlet on the possible and no tight bends in pipe.
  • Page 13: Electrical Connection

    Prior to installation Electrical connection The extractor hood should only be con- Preparing the wall nected to an earthed socket that has been The wall must be flat and perpendicular. installed according to relevant regulations. The provided screws and wall plugs are If possible, site the earthed socket directly suitable for solid masonry.
  • Page 14: Installation

    Installation This extractor hood is intended to be Note: Take into account any special mounted onto the kitchen wall. accessories that are going to be fitted. 1. Remove the grease filter 5. Attach the 2 enclosed spacers to the (refer to Operating Instructions). fixing bracket for the flue duct panelling.
  • Page 15 Installation 08. Screw in lower screws (hex screws). Warning: The interior walls of the flue panelling can have sharp edges – Risk of If any pressure is exerted on the injury –. glass screen when tightening the We recommend that you wear gloves when screws it could lead to glass breakage.