hit counter script

Troubleshooting The Module (Basics) - Cisco Aironet 1600 Deployment Manual

Release 7.5
Hide thumbs Also See for Aironet 1600:
Table of Contents

Advertisement

Understanding 802.11ac and the option module
Figure 72
Since 802.11ac is fairly new, having a dedicated module handling the VHT (Very High Throughput)
requests makes it easy to see which clients are connected at 802.11ac rates and which 802.11ac clients
are actually connecting at 802.11n rates. This is accomplished by observing the SLOT ID.
Figure 73

Troubleshooting the module (basics)

Common issues arise because:
Cisco Aironet Series 1600/2600/3600 Access Point Deployment Guide, Release 7.5
56
Understanding RF radio interfaces
Understanding client associations
Module isn't screwed down tightly
Not enough PoE power (requires 802.3at) 18W
Not configured correctly
Not understanding the radios operate "together" so you need to configure the radio in slot 1 (5 GHz
internal) first