hit counter script
Download Print this page
Kenmore 30" ELECTRIC RANGE Installation Instructions
Kenmore 30" ELECTRIC RANGE Installation Instructions

Kenmore 30" ELECTRIC RANGE Installation Instructions

Hide thumbs Also See for 30" ELECTRIC RANGE:

Advertisement

INSTALLATION
AND SERVICE
MUST BE PERFORMED
BYA QUALIFIED
INSTALLER.
IMPORTANT:
SAVE FOR LOCAL ELECTRICAL
INSPECTOR'S
USE.
READ AND SAVE THESE INSTRUCTIONS
FOR FUTURE
REFERENCE.
Clearances
and Dimensions
1.
Provide adequate clearances between the range and adjacent combustible surfaces.
2.
Location--Check
location where the range will be installed. Check for proper electrical supply, and the stability
of the floor.
3.
Dimensi_ns that are sh_wn must be used_ GiVen dimensi_ns pr_Vide minimum c_earance_ C_ntact surface must
be solid and level.
RANGE
OVERALL
DIMENSIONS
25-3/4"
3o"---.j,,...._
4, 1/2"
,
6 .+1/8
-5/8"
',\
29-7/8"
-_
DoorOpen
\4_'_
_--
-
Fig,
1
Depth is 28-13/32"with door handle.
RANGEELECTRICAL
CONNECTIONS
_-AII d imensionsfor
I eleectriaCai
ImOutlme.t
location
_-Centenine s o s
e e e
II
of range
electrical outlet must
I
I
be installedfor flush to
II.4
wa, osta,ation.
j
....
2-5/8"for models equipped
withwarmer drawers,
3-1/2"for models equipped
with storage drawers
Fig, 2
FRONT--
TYPICALCABINETINSTALLATION
V,E!)
30"
Minimum*
Minimumto
1"-_ ÷
/
t
Minimumto
wall on either
_[_
18" cabinetson
side of range
®®
®®
eitherside
above 36" height.
_,
of range.
Fig. 3
_
30" _
SIDE
VIEW
1-13"-_
Maximumdepth
for cabinets
above rangetop.
0" clearancebelow cookingtop and at rearof range,
*30" MINIMUMCLEARANCEBETWEENTHE TOP OF THE COOKINGSURFACEAND THE BOTTOMOF AN UNPROTECTED WOOD OR
METAL CABINET;OR 24" MINIMUMWHEN BOTTOMOF WOOD OR METAL CABINETIS PROTECTEDBY NOT LESS THAN 1/4" FLAME
RETARDANT MILLBOARD COVEREDWITH NOT LESSTHAN NO. 28 MSGSHEETSTEEL,0.015" STAINLESSSTEEL,0.024"ALUMINUMOR
0.020"COPPER.0" CLEARANCE ISTHE MINIMUMFORTHE REAROF THE RANGE.FOLLOW ALL DIMENSION REQUIREMENTS PROVIDED
ABOVE TO PREVENTPROPERTYDAMAGE,POTENTIALFIREHAZARD,AND INCORRECTCOUNTERTOP AND CABINETCUTS.
TO ELIMINATETHE RISK OF BURNSOR FIRE BY REACHINGOVERHEATEDSURFACEUNITS,CABINETSTORAGESPACE LOCATED
ABOVE THE SURFACEUNITS SHOULDBE AVOIDED.IF CABINETSTORAGEIS TO BE PROVIDED,THE RISK CAN BE REDUCEDBY
INSTALLING A RANGEHOOD THAT PROJECTSHORIZONTALLY A MINIMUMOF 5" BEYONDTHE BOTTOMOF THE CABINETS.
IMPORTANT
SAFETY
INSTRUCTIONS
_!_VlVl_,1_I_ll_[_ll
If the information in this manual is not followed exactly, a fire or
electrical shock may result causing property damage, personal injury or death.
Important Notes to the Installer
Read all instructions
contained in these installation
instructions
before
installing range.
Remove all packing material from the oven compartments before connecting
the gas & electrical supply to the range.
Observe all governing codes and ordinances.
Be sure to leave these instructions with the consumer.
• ALL RANGES
CAN TIP
• INJURYTO
PERSONS
COULD
RESULT
• INSTALL ANTI-TIP
DEVICE PACKED WITH
RANGE
• SEE INSTALLATION
INSTRUCTIONS
Important Note to the Consumer
Keep these instructions with your owner's guide for future reference.
As when using any appliance generating heat, there are certain safety precautions you should follow. These are listed in
the Use & Care Manual, read it carefully.
Be sure your range is installed and grounded properly by a qualified installer or service technician.
Make sure the wall coverings around the range can withstand the heat generated by the range.
To eliminate the need to reach over the surface elements, cabinet storage space above the elements should be avoided.
pin 316454901 (0509) EN
1
EspaSol
- Paginas
5-8

Advertisement

loading

Summary of Contents for Kenmore 30" ELECTRIC RANGE

  • Page 1 INSTALLATION AND SERVICE MUST BE PERFORMED BYA QUALIFIED INSTALLER. IMPORTANT: SAVE FOR LOCAL ELECTRICAL INSPECTOR'S USE. READ AND SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE. Clearances and Dimensions Provide adequate clearances between the range and adjacent combustible surfaces. Location--Check location where the range will be installed. Check for proper electrical supply, and the stability of the floor.
  • Page 2 to the wall, drill pilot hole at an approximate 20 ° downward angle BEFORE STARTING (See Fig. 5). Tools You Will Need If bracket is to be mounted to masonry or ceramic floors, drill a 5/ For leveling legs and Anti-Tip Bracket: 32"...
  • Page 3 See Range C onnection Opening Size Chart ( Figs. 9&10) f or cord kitampere rating information. Terminals onend ofwires must b eeither c losed l oop oropen-end spade l ugs withupturned ends. 2b. MODELS REQUIRING POWER SUPPLY CORD KIT. RISK OF FIRE OR ELECTRICAL SHOCK MAY OCCUR IF AN...
  • Page 4 or 4B, POWER CORD CONNECTIONS 3-Wire Connection (3-Wire Connection Instructions, For existing installations ONLY Factory installed connections (DO NOT LOOSEN) - Refer to Fig. 13). Terminal Follow the manufacturer's installation instructions supplied with the strain relief and install (Also see Figs. 9, 10 & 1 1). Connect Insert the end connectors for Line 1, Line 2 and Neutral...