hit counter script
Download Print this page
Toshiba 1600EP Series Quick Instillation Manual
Toshiba 1600EP Series Quick Instillation Manual

Toshiba 1600EP Series Quick Instillation Manual

Hide thumbs Also See for 1600EP Series:

Advertisement

Purpose
This Quick Installation Guide (QIG) provides the minimum information needed to connect and startup your 1600EP UPS. The
complete 1600EP Users Manual and supporting documentation are provided in the accompanying CD (P/N 62350). The self-
starting CD requires a PC with a web browser (e.g Microsoft Explorer) and a PDF file viewer (e.g. Adobe Acrobat Reader).
If requested, a printed manual may be provided at no cost from Toshiba International Corporation. Contact UPS Marketing at
800-231-1412.
NOTE: This QIG is not intended to replace the 1600EP Users Manual.
Toshiba International Corporation reserves the right, without prior notice, to update information, make product changes, or
discontinue any product or service identified in this publication.
Toshiba International Corporation shall not be liable for direct, indirect, special, or consequential damages resulting from the use
of the information contained within this QIG.

QUALIFIED PERSONNEL ONLY

Qualified person is one that has the skills and knowledge relating to the construction, installation, operation, and maintenance
of the electrical equipment and has received safety training on the hazards involved (Refer to the latest edition of NFPA 70E for
additional safety requirements).
Qualified personnel shall:
1.
Have read the entire operation manual.
2.
Be trained and authorized to safely energize, de-energize, ground, lockout and tag circuits and equipment, and clear faults
in accordance with established safety practices.
3.
Be trained in the proper care and use of protective equipment such as safety shoes, rubber gloves, hard hats, safety
glasses, face shields, flash clothing, etc., in accordance with established safety practices.
4.
Be trained in rendering first aid.
5.
Be knowledgeable of batteries and the required handling and maintenance precautions.
For further information on workplace safety visit www.osha.gov.
Misuse of this equipment may result in human injury and equipment damage. In no event will Toshiba Corporation be responsible
or liable for either indirect or consequential damage or injury that may result from the misuse of this equipment.
DO NOT open or mutilate the batteries. Released electrolyte is harmful to the eyes and skin and could also be toxic.
DO NOT dispose of the battery module in a fire. The batteries inside may explode.
To be performed by Qualified Personnel Only:
1.
Verify that the UPS is off and that the power is disconnected from the power source.
2.
Remove watches, rings or other metal objects.
3.
Use tools with insulated handles to prevent inadvertent shorts.
4.
Wear rubber safety gloves and boots.
5.
DO NOT place tools or any metal parts on top of batteries.
Contact with any part of a grounded battery can result in electrical shock.
The likelihood of shock will be reduced if such grounds are removed prior to installation or maintenance.
62410-000
September 2009
Quick Instillation Guide
1600EP Series UPS
1

Advertisement

loading

Summary of Contents for Toshiba 1600EP Series

  • Page 1: Qualified Personnel Only

    For further information on workplace safety visit www.osha.gov. Misuse of this equipment may result in human injury and equipment damage. In no event will Toshiba Corporation be responsible or liable for either indirect or consequential damage or injury that may result from the misuse of this equipment.
  • Page 2: Installation Precautions

    (oversizing the UPS for lock rotor current would be required). DO NOT attempt to disassemble, modify, or repair the UPS. Repairs and servicing should only be performed by Toshiba Field Service personnel.
  • Page 3 NOTE 1 – If AC input power is 208 Vac rated, short terminals 11 and 12 with the provided jumper wire/bus bar. DO NOT jumper terminal 13 to 12 or 11. Factory Setting is 208Vac. Use the jumper wire/bus strip provided by Toshiba. DO NOT add any additional jumpers.
  • Page 4: Wire Size And Tightening Torque

    See the manual, page 48, for knock-out hole sizes on the back of each model. FAQs Below are some Frequently Asked Questions concerning installation of the 1600EP Series UPS. NOTICE The batteries for the UPS must be installed while the UPS is energized.