Dell PowerEdge Modular Systems Hardware Owner’s Manual...
Page 2
Other trademarks and trade names may be used in this publication to refer to either the entities claiming the marks and names or their products. Dell Inc. disclaims any proprietary interest in trademarks and trade names other than its own.
Program and UEFI Boot Manager" on page 137. <F10> Enters System Services, which opens the Dell Unified Server Configurator (USC). The Dell USC allows you to access utilities such as embedded system diagnostics. For more information, see the Unified Server Configurator documentation.
System Overview Your system can include up to 16 half-height blades (server modules), eight full-height blades, or a combination of the two blade types (see Figure 1-1, Figure 1-2, and Figure 1-3). To function as a system, a blade is inserted into an enclosure (chassis) that supports power supplies, fan modules, a Chassis Management Controller (CMC) module, and at least one I/O module for external network connectivity.
Page 15
Figure 1-2. Blade Numbering – Full Height Blades Figure 1-3. Blade Numbering – Mixed Full-Height and Half-Height Blades About Your System...
System Control Panel Features Figure 1-4. Control Panel Features USB port (mouse only) USB port (keyboard only) video connector system power button power indicator About Your System...
Page 17
Table 1-1. Control Panel Features Item Indicator, Icon Description Button, or Connector System power Turns the system on and off. Press to turn button on the system. Press and hold 10 seconds to turn off the system. NOTE: The system power button controls power to all of the blades and I/O modules in the enclosure.
LCD Module The LCD module provides an initial configuration/deployment wizard, as well as easy access to infrastructure and blade information, and error reporting. See Figure 1-5. Figure 1-5. LCD Display LCD screen selection ("check") button scroll buttons (4) About Your System...
LCD Module Features The primary function of the LCD module is to provide real-time information on the health and status of the modules in the enclosure. LCD module features include: • A deployment setup wizard that allows you to configure the CMC module’s network settings during initial system set up.
Page 20
Configuration Wizard The CMC is preset for DHCP . To use a static IP address, you must toggle the CMC setting from DHCP to a static address by either running the LCD Configuration Wizard, or by using a management station and CLI commands.
Page 21
Main Menu The Main Menu options include links to the LCD Setup Menu, Server Menu, and Enclosure Menu. LCD Setup Menu You can change the default language and start-up screen for the LCD menu screens using this menu. Server Menu From the Server Menu dialog box, you can highlight each blade in the enclosure using the arrow keys, and view its status.
Blade Features Figure 1-6. Front Panel Features – PowerEdge M915 blade handle release button hard drives (2) blade status/identification indicator USB connectors (3) blade power button blade power indicator About Your System...
Page 23
Figure 1-7. Front Panel Features – PowerEdge M910 blade handle release button hard drives (2) blade status/identification indicator USB connectors (3) blade power button blade power indicator About Your System...
Page 24
Figure 1-8. Front Panel Features – PowerEdge M905 and M805 blade handle release button hard drives (2) blade status/identification indicator USB connectors (3) blade power button blade power indicator About Your System...
Page 25
Figure 1-9. Front Panel Features – PowerEdge M710HD blade handle release button hard drives (2) blade status/identification indicator USB connectors (2) blade power button blade power indicator About Your System...
Page 26
Figure 1-10. Front Panel Features – PowerEdge M710 blade handle release button hard drives (4) USB connectors (3) blade status/identification indicator blade power button blade power indicator About Your System...
Page 27
Figure 1-11. Front Panel Features – PowerEdge M610x blade handle release button hard drive (2) expansion-card filler-bracket expansion-card slot (2) retention latch with captive screw blade status/identification indicator USB connector (2) blade power button blade power indicator About Your System...
Page 28
Figure 1-12. Front Panel Features – PowerEdge M610 blade handle release button hard drives (2) blade status/identification indicator USB connectors (2) blade power button blade power indicator About Your System...
Page 29
Figure 1-13. Front Panel Features – PowerEdge M605 and M600 blade handle release button hard drives (2) blade status/identification indicator USB connectors (2) blade power button blade power indicator About Your System...
Page 30
Table 1-3. Blade Control Panel Features Feature Icon Description Blade power Off – Power is not available to the blade, the blade is indicator in standby mode, the blade is not turned on, or the blade is installed incorrectly. For detailed information on installing a blade, see "Installing a Blade"...
The USB drives can be used to configure the blade. NOTE: These blades support only Dell-branded USB 2.0 drives. The drive must be horizontal and level to operate properly. Use the optional external drive storage tray to support the drive while in use.
Page 32
The hard-disk drives plug into the internal storage backplane inside the blade. On blades with a diskless configuration, all hard drive slots must be filled with hard drive blanks, and the internal storage backplane must still be installed to maintain proper airflow. See Figure 1-14 for information on the hard-drive indicators.
Page 33
Table 1-4. Hard-Drive Indicators Condition Drive-Status Indicator Pattern Identifying drive/preparing Blinks green two times per second for removal Drive ready for insertion or removal NOTE: The drive status indicator remains off until all hard drives are initialized after system power is applied. Drives are not ready for insertion or removal during this time.
Back-Panel Features Figure 1-15. Back-Panel Features fan modules (9) primary CMC module I/O modules (6) optional iKVM module secondary CMC module power supplies (6) About Your System...
Page 35
Figure 1-16. Back-Panel Module Bay Numbering C2 B2 A2 CMC 2 CMC 1 A1 B1 C1 iKVM About Your System...
Power Supply Indicator NOTE: The power supplies must be connected to a PDU, not directly to an electrical outlet. The power supplies require a 200-240 V power source. • A 2700 W power supply can be connected to a 110 V AC power source. •...
Table 1-5. Power Supply Indicators Indicator Icon Description Power supply Green indicates that the power supply is operational and status providing DC power to the system. Fault indicator Amber indicates a problem with the power supply, which can result from either a failed power supply or a failed fan within the power supply.
Table 1-6. Fan Indicators Indicator Indicator Description State Power indicator Green The power supply is connected to an AC power source. AC power not connected. Fault indicator Amber The fan is in a fault condition. Fan not faulty. Identifying Midplane Version The version of the midplane installed in the enclosure is displayed in the Midplane Revision field under the Summary tab of the CMC Web-based interface.
Page 39
Figure 1-19. Identifying Midplane Version 1.1 midplane identification label (2) About Your System...
Page 40
Figure 1-20. Identifying Midplane Version 1.0 midplane identification label (2) About Your System...
NOTE: The iKVM USB ports do not support storage devices. – RJ-45 ACI port for tiering with Dell and Avocent analog KVM and KVM over IP switches with ARI ports. NOTE: Although the ACI port is an RJ-45 connector and uses Cat5 (or better) cabling, it is not an Ethernet network interface port.
Page 42
Figure 1-21. Avocent iKVM Switch Module identification indicator status indicator ACI port for tiering connection only USB connectors (2) for keyboard and mouse CAUTION: Do not connect the ACI port to a LAN device such as a network hub. Doing so may result in equipment damage. video connector Table 1-8.
Page 43
Allows a monitor to be connected to the system. connector ACI port Allows connection of one or more servers to a Dell console switch with an Analog Rack Interface (ARI) port, such as an external digital or analog switch. Link indicator Off The ACI is not connected to the external switch.
Tiering the Avocent iKVM Switch From an Analog KVM Switch The Avocent iKVM switch can be tiered from analog KVM switches such as the Dell 2160AS and 180AS, as well as many Avocent analog KVM switches. Many switches may be tiered without the need for a Server Interface Pod (SIP) (see Table 1-9).
Page 45
To configure the analog switch: 1 Press <Print Screen> to open the OSCAR Main dialog box. 2 Click Setup DevicesDevice Modify. 3 Select the 16-port option to match the number of blades in your system. 4 Click OK to exit OSCAR. 5 Press <Print Screen>...
Avocent DSR 1024 Dell USB SIP required with Cat 5 cable To tier the iKVM switch module from a Dell 2161DS, 180AS, or 2160AS console switch: If the switch does not require a SIP to connect to the iKVM (see Table 1-10), •...
Page 47
Resynchronizing the Server List at the Remote Client Workstation Once the iKVM switch is connected, the blades appear in OSCAR. You now need to resynchronize the servers on any remote workstation to ensure that the blades are available to any remote users connected to the console switch through the Remote Console Switch software.
CMC Module Figure 1-22. CMC Module Features Ethernet connector Gb1 link indicator (2) Ethernet connector STK ("stack") - activity indicator (2) used for daisy-chaining CMCs in separate enclosures DB-9 serial connector for local optional secondary CMC (CMC 2) configuration primary CMC (CMC 1) amber fault indicator blue status/identification indicator power indicator...
Page 49
Table 1-11. CMC Module Features Indicator Pattern Description Network LAN is not linked. interface Green LAN is linked. controller link indicator Network LAN is not active. interface Amber Indicates that the system CMC and the LAN are controller blinking communicating. activity indicator Power indicator Off...
Page 50
Figure 1-22) for the system to power up. If a second, optional CMC module is installed, failover protection and hot-plug replacement is available. See the latest Dell Chassis Management Controller User's Guide at support.dell.com/manuals for complete instructions on how to set up and operate the CMC module.
Page 51
Figure 1-23. CMC Daisy-Chaining management network secondary CMC primary CMC About Your System...
I/O Connectivity The M1000e enclosure supports three layers of I/O fabric, selectable between combinations of Ethernet, fibre-channel, and Infiniband modules. You can install up to six hot-swappable I/O modules in the enclosure, including fibre- channel switches, fibre-channel pass-throughs, Infiniband switches, Ethernet switches, and Ethernet pass-through modules.
NOTE: Modules designed specifically for Fabric B or Fabric C cannot be installed in slots A1 or A2, as indicated by the color-coded labeling on the faceplate of each module. Fabric B Fabric B is a 1 to 40 Gb/sec redundant fabric, supporting I/O module slots B1 and B2.
Page 54
support quad-port mapping. This behavior is limited to Fabric A slots only and is automatically enabled or disabled depending on the type of IO module installed. NOTE: A quad-port Network Daughter Card must be used with a 48-port switch module (32 internal ports) for all the ports to be active. NOTE: LOM firmware updates are applied only to the enabled ports on a quad-port network daughter card.
Mezzanine Cards PowerEdge M610x Only PowerEdge M610x supports two mezzanine cards. Mezzanine cards can be installed in both the slots on the midplane interface card. NOTE: PowerEdge M610x is a full-height blade but supports only two mezzanine cards in the expansion bay. The two mezzanine slots on the M610x system board (MEZZ2_FAB_B and MEZZ1_FAB_C) are reserved for the mezzanine interface card.
Page 56
Table 1-13. Supported I/O Module Configurations Fabric A Fabric B Fabric C I/O Bay A1, I/O Bay B1, I/O Bay C1, Mezzanine Mezzanine Card Card Standard none none Ethernet none none Integrated switch module or pass- through module Standard Ethernet none Ethernet Ethernet...
Page 57
(continued) Table 1-13. Supported I/O Module Configurations Fabric A Fabric B Fabric C I/O Bay A1, I/O Bay B1, I/O Bay C1, Mezzanine Mezzanine Card Card Standard none Fibre Ethernet none Fibre Integrated Channel switch Channel mezzanine module or switch card pass- module or...
(continued) Table 1-13. Supported I/O Module Configurations Fabric A Fabric B Fabric C I/O Bay A1, I/O Bay B1, I/O Bay C1, Mezzanine Mezzanine Card Card Standard Fibre Ethernet Ethernet Fibre Ethernet Integrated Channel mezzanine switch Channel switch mezzanine card module or switch or module or...
Page 59
Dual-Port Mezzanine Cards Each mezzanine card has two port connections. For a full-height blade in bay • Mezzanine card 1, connection 1 connects to I/O module C1, port n. Mezzanine card 1, connection 2 connects to I/O module C2, port n. •...
Page 60
Figure 1-24. Example of PowerEdge M610x Port Mapping of – Blade 2 About Your System...
Page 61
Table 1-15. I/O Module Port Assignments - Full-Height Blades (not applicable for PowerEdge M610x) Blade 1 I/O Module Mezz1_Fab_C Port 1 Port 1 Mezz2_Fab_B Port 1 Port 1 Mezz3_Fab_C Port 9 Port 9 Mezz4_Fab_B Port 9 Port 9 Blade 2 I/O Module Mezz1_Fab_C Port 2...
Page 62
Blade 4 I/O Module Mezz1_Fab_C Port 4 Port 4 Mezz2_Fab_B Port 4 Port 4 Mezz3_Fab_C Port 12 Port 12 Mezz4_Fab_B Port 12 Port 12 Blade 5 I/O Module Mezz1_Fab_C Port 5 Port 5 Mezz2_Fab_B Port 5 Port 5 Mezz3_Fab_C Port 13 Port 13 Mezz4_Fab_B Port 13...
Page 63
Blade 8 I/O Module Mezz1_Fab_C Port 8 Port 8 Mezz2_Fab_B Port 8 Port 8 Mezz3_Fab_C Port 16 Port 16 Mezz4_Fab_B Port 16 Port 16 Figure 1-25 shows the port connections for a full-height blade in bay 3 with four mezzanine cards. Figure 1-25.
Page 64
NOTE: For a detailed mapping of each PowerEdge system, see the document Quadport Capable Hardware for the M1000e Modular Chassis on support.dell.com/manuals. Table 1-16. I/O Module Port Assignments—Full-Height Blades (not applicable for PowerEdge M610x) Blade and Blade (...
Page 65
(continued) Table 1-16. I/O Module Port Assignments—Full-Height Blades (not applicable for PowerEdge M610x) Blade and Blade ( + 8) I/O Module NOTE: n denotes a variable value from 1 to 8. Mezz_FAB_C_Blade Port n+8_Port2 (n+8) Mezz_FAB_C_Blade Port n+8_Port3 (n+24) Mezz_FAB_C_Blade Port n+8_Port4 (n+24)
Page 66
Half-Height Blades Standard LOM (Dual-Port) and Network Daughter Card (Quad-Port) Mapping Each standard LOM has two port connections. For a half-height blade in bay n: • Integrated LOM, connection 1 connects to I/O module A1, port n. Integrated LOM, connection 2 connects to I/O module A2, port n. Half-height blades with Network Daughter Card (PowerEdge M710HD) hosts two network controllers (LOM1 and LOM2), each with two port connections.
Page 67
Table 1-18. Example of I/O Module Port Assignments - Half-Height Blade 1 Blade 1 I/O Module Integrated NIC Port 1 Port 1 Mezzanine Port 1 Port 1 Card C Mezzanine Port 1 Port 1 Card B Figure 1-26 shows the port connections for a half-height blade in bay 1 with two mezzanine cards.
Page 68
Figure 1-26. Example of Half-Height Blade Port Mapping About Your System...
Mezz_FAB_C_Blade n_Port4 Port (n+16) Dell PowerConnect-KR 8024-k Switch The PowerConnect M8024-k switch provides 16 internal 10 GbE ports, four external 10 GbE SFP+ ports, and one 10 GbE expansion slot for 10 GbE external uplinks. The expansion slot on the front panel can support: •...
Page 70
• A 10 Gb Ethernet module with two copper 10GBASE-T uplinks This module is hot-swappable and may be installed in Fabric A, B, or C. Figure 1-27. Dell PowerConnect-KR 8024-k Switch SFP+ ports (4) console management connector power indicator status/identification indicator...
Dell M8428-k 10 Gb Converged Network Switch The Dell M8428-k 10 Gb Converged Network switch module supports FCoE protocols and allows Fibre Channel traffic to travel over 10 Gbps Converged Enhanced Ethernet (DCB) networks. This module consists of: • Four 8 Gbps external autosensing Fibre Channel ports •...
Page 72
Figure 1-28. Dell M8428-k 10 Gb Converged Network Switch LED status indicators (12) serial port (RJ-45 connector) module status indicator diagnostic status indicator power indicator 8 Gb Fibre Channel ports (ports 25–27 and port 0) 10 GbEE ports (ports 17–24)
Mellanox M3601Q QDR Infiniband Switch I/O Module The Mellanox M3601 Infiniband switch I/O module includes 32 4x QDR Infiniband ports. Of these, 16 ports are external uplink ports, while 16 internal ports provide connectivity to the blades in the enclosure. This module occupies two I/O module slots.
Mellanox M2401G Infiniband Switch I/O Module The Mellanox M2401G Infiniband switch I/O module includes 24 4x DDR Infiniband ports. Eight ports are external uplink ports, while 16 internal ports provide connectivity to the blades in the enclosure. Figure 1-30. Mellanox M2401G Infiniband Switch Module Infiniband ports (8) port link status indicators (8) port activity indicators (8)
Table 1-20. Mellanox M2401G Infiniband Switch Indicators Indicator Pattern Description Link indicator Green, on Physical link established Green, off No physical link present Activity indicator Amber, on Valid logical link to Infiniband network established Amber, blinking Data transfer is in progress Amber, off No logical link to Infiniband network Cisco SFS M7000e Infiniband Switch Module...
Page 76
Figure 1-31. Cisco SFS M7000e Infiniband Switch Module Features Infiniband ports (8) port status indicator (8) diagnostic status indicator power indicator Table 1-21. Cisco SFS M7000e Infiniband Switch Indicators Indicator Type Pattern Description Infiniband Link error or Subnet Manager not operating port status Green flickering I/O activity on port...
(continued) Table 1-21. Cisco SFS M7000e Infiniband Switch Indicators Indicator Type Pattern Description Module status Switch is not ready indicator Blue on Switch operating normally Amber on or Fault condition in module blinking Module power Power to the module is off indicator Green Module has power...
Page 78
Figure 1-32. Cisco Ethernet Switch Module Features Stackwise Plus connectors (not 10/100/1000 Mb Ethernet enabled in CBS 3032) connectors (4) option bays (2) Cisco status indicators mode button console port for switch management status/identification indicator power indicator About Your System...
PowerConnect M6348 1 Gb Ethernet Switch I/O Module The PowerConnect M6348 is a hot-swappable 48-port 1 Gb Ethernet switch. While 16 ports are external uplink ports, the remaining 32 internal ports provide connectivity to the blades within the enclosure with a maximum bandwidth of 1 Gbps each.
Page 80
Figure 1-33. PowerConnect M6348 Switch Module standard 10/100/1000 Mb SFP+ connectors (2) Ethernet connectors (16) CX4 stacking connectors (2) console management connector status/identification indicator power indicator About Your System...
PowerConnect M8024 10 Gb Ethernet Switch I/O Module The PowerConnect M8024 switch module incorporates two option bays that support the following modules: • A 10 Gb Ethernet module with four optical SFP+ connectors • A 10 Gb Ethernet module with three copper CX4 uplinks You can initially configure the switch using either of two methods: •...
Page 82
Figure 1-34. PowerConnect M8024 Switch Module optional module with four SFP+ optional module with three CX4 ports ports serial connector for optional USB status/identification indicator type-A form-factor cable power indicator About Your System...
PowerConnect M6220 Ethernet Switch Module The PowerConnect M6220 Ethernet switch module includes four external 10/100/1000 Mbps Ethernet connectors and one USB type A form factor serial connector. See Figure 1-35. Two option bays support the following three module options: • A resilient stacking module with 2 x 24 Gb stacking ports •...
Page 84
Figure 1-35. PowerConnect M6220 Ethernet Switch Module Features optional module (2) (dual 10 Gb standard 10/100/1000 Mb Ethernet Ethernet uplink module shown) connectors (4) serial connector (USB type-A form status/identification indicator factor) power indicator About Your System...
Dell 10 GbE KR Pass-Through I/O Module The 10 GbE KR pass-through module supports 10 Gb connections and provides a direct connection between the optional internal Ethernet KR mezzanine card or KR network daughter card in the blade and an external Ethernet device.
Figure 1-36. Dell 10 GbE KR Pass-Through I/O Module SFP+ ports (16) green/amber indicators (two per port) status/identification indicator power indicator Dell 8/4 Gbps Fibre Channel Pass-Through I/O Module The 8G Fibre Channel pass-through module provides a bypass connection between a Fibre Channel mezzanine card in the blade and optical transceivers.
Page 87
NOTE: To ensure proper functionality, use only the Short Wave Small Form Factor Pluggable (SFP) transceivers provided with this module. Figure 1-37. Dell 8/4 Gbps Fibre Channel Pass-Through I/O Module Fibre Channel ports (16) port status indicators status/identification indicator power indicator...
10 Gb Ethernet Pass-Through Module II The Dell 10 Gb Ethernet pass-through module II supports 10 Gb connections and provides a direct connection between the optional internal Ethernet mezzanine card in the blade and an external Ethernet device. The Ethernet pass-through modules are hot-swappable and may be installed in Fabric B or Fabric C.
Page 89
Figure 1-38. 10 Gb Ethernet Pass-Through Module II SFP+ cages (16) green/amber indicators (two per port) status/identification indicator power indicator About Your System...
10 Gb Ethernet Pass-Through I/O Module The 10 Gb Ethernet pass-through module supports 1/10 Gb connections and provides a direct connection between the optional internal Ethernet mezzanine card in the blade and an external Ethernet device. The Ethernet pass-through modules are hot-swappable and may be installed in Fabric B or Fabric C.
Page 91
Figure 1-39. 10 Gb Ethernet Pass-Through I/O Module Features SFP+ cages (16) green/amber indicators (two per port) status/identification indicator power indicator About Your System...
4 Gbps Fibre Channel Pass-Through Module The 4 Gbps Fibre Channel pass-through module provides a bypass connection between a Fibre Channel mezzanine card in the blade and optical transceivers for direct connection into a Fibre Channel switch or a storage array (see Figure 1-40).
Page 93
Figure 1-40. 4 Gbps Fibre Channel Pass-Through Module Features SFP Fibre Channel connector (16) Fibre Channel green/amber indicators (two per port) status/identification indicator power indicator About Your System...
Page 94
Table 1-22. Fibre Channel Pass-Through Indicators Indicator Type Pattern Description Power Power to the module is off indicator Green Module has power Status/ Blue on Primary module in a stack, if applicable identification Blue off Secondary module in a stack indicator Amber flashing Fault condition in module...
(continued) Table 1-22. Fibre Channel Pass-Through Indicators Indicator Type Pattern Description Fibre Channel Green off, amber Power off Port LEDs with Qlogic Green off, amber Online, 1 Gb or 2 Gb link mezzanine card Installed Green on, amber Online, 4 Gb link Green off, amber I/O activity, 1 Gb or 2 Gb flashing...
Page 96
Figure 1-41. Brocade M5424 FC8 I/O Module Fibre Channel port (8) Fibre Channel port status indicator (8) Fibre Channel port speed serial port (RJ-45 connector) indicator (8) module status indicator status/identification indicator power indicator About Your System...
Page 97
Table 1-23. Brocade M5424 FC8 I/O Module indicators Indicator Type Pattern Description Fibre Channel No signal carrier port status Amber on Signal present but not online indicator Green on Online, but no activity Green blinking Online but segmented slowly Green blinking Internal loopback quickly Green flickering...
Brocade M4424 SAN I/O Module The Brocade M4424 SAN I/O module includes eight external autosensing Fibre Channel ports (four ports are enabled in the standard configuration and four additional ports may be enabled as an optional upgrade), 16 internal ports, and one serial port with an RJ-45 connector. The external Fibre Channel ports operate at 1 Gb/sec, 2 Gb/sec, or 4 Gb/sec.
Page 99
Figure 1-42. Brocade M4424 SAN I/O Module Features Fibre Channel port (8) Fibre Channel port status indicator (8) Fibre Channel port speed serial port (RJ-45 connector) indicator (8) module status indicator status/identification indicator power indicator About Your System...
Page 100
Table 1-24. Brocade M4424 SAN I/O Module Indicators Indicator Type Pattern Description Fibre Channel No signal carrier port status Amber on Signal present but not online indicator Green on Online, but no activity Green blinking Online but segmented slowly Green blinking Internal loopback quickly Green flickering...
10/100/1000 Mb Ethernet Pass-Through Module The Ethernet pass-through module supports 10/100/1000 Mb connections, and provides a direct connection between the optional internal Ethernet mezzanine card in the blade and an external Ethernet device (see Figure 1-43). The Ethernet pass-through modules are hot-swappable, and may be installed in any of the three Fabrics.
Page 102
link indicator (16) RJ45 Ethernet connector (16) status/identification indicator power indicator activity indicator (16) NOTE: Connectors on the Ethernet pass-through module correspond directly to the blade number. For example, blade 5 is connected to port 5 on the Ethernet pass- through module.
LCD Status Messages The following LCD messages refer to events recorded in the System Event Log (SEL). (The messages are shown here in "simple" text format.) For information on the SEL and configuring system management settings, see the systems management software documentation. NOTE: If your system fails to boot, press the System ID button for at least five seconds until an error code appears on the LCD.
Page 104
(continued) Table 1-26. LCD Status Messages Code Text Cause Corrective Actions Ambient temperature has See "Troubleshooting Fan E1114 Ambient Temp reached a point outside of Modules" on page 315. exceeds the allowed range. allowed range. Memory has exceeded Remove AC power to the E1116 Memory allowable temperature and system for 10 seconds and...
Page 105
(continued) Table 1-26. LCD Status Messages Code Text Cause Corrective Actions Specified processor Reseat the processor(s). E1229 CPU # VCORE VCORE voltage regulator See "Troubleshooting Regulator has failed. Processors" on page 322. failure. Reseat CPU. If the problem persists, see "Getting Help" on page 361.
(continued) Table 1-26. LCD Status Messages Code Text Cause Corrective Actions Speed of the specified fan See "Troubleshooting Fan E1311 Fan module ## in specified module is Modules" on page 315. RPM exceeding outside of intended range. Check operating range. fan.
Page 107
(continued) Table 1-26. LCD Status Messages Code Text Cause Corrective Actions The system BIOS has Remove AC power to the E141F CPU # reported a processor system for 10 seconds and protocol protocol error. restart the system. error. Power cycle AC. If the problem persists, see "Getting Help"...
Page 108
(continued) Table 1-26. LCD Status Messages Code Text Cause Corrective Actions Specified power supply has See "Troubleshooting E1618 Predictive detected a condition that Power Supply Modules" failure on may predict a future power- on page 314. Power Supply down event, such as an # (### W).
(continued) Table 1-26. LCD Status Messages Code Text Cause Corrective Actions The system configuration Turn off power to the E1629 Power requires more power than system, reduce the required > the power supplies can hardware configuration or PSU wattage. provide, even with install higher-wattage Check PSU and throttling.
Page 110
(continued) Table 1-26. LCD Status Messages Code Text Cause Corrective Actions Memory configured, but is See "Troubleshooting E2012 Memory unusable. Blade Memory" on configured page 319. but unusable. Check DIMMs. The system BIOS failed to See "Troubleshooting E2013 BIOS unable copy its flash image into Blade Memory"...
Page 111
(continued) Table 1-26. LCD Status Messages Code Text Cause Corrective Actions Programmable interval Remove AC power to the E2018 Programmable timer error. system for 10 seconds and Timer error. restart the system. Power cycle If the problem persists, see "Getting Help" on page 361.
(continued) Table 1-26. LCD Status Messages Code Text Cause Corrective Actions BIOS shutdown test failure. Remove AC power to the E201D Shutdown test system for 10 seconds and failure. restart the system. Power cycle If the problem persists, see "Getting Help" on page 361.
Page 113
(continued) Table 1-26. LCD Status Messages Code Text Cause Corrective Actions The system BIOS has Remove AC power to the E2111 SBE log disabled memory single-bit system for 10 seconds and disabled on error (SBE) logging and restart the system. DIMM ##.
Page 114
NOTE: For the full name of an abbreviation or acronym used in this table, see the Glossary at support.dell.com/manuals. About Your System...
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Page 116
(continued) Table 1-27. Blade Messages Message Causes Corrective Actions This warning occurs if Ensure that the expansion- Warning: PCIe BIOS does not discover card riser is installed in the expansion riser the expansion-card riser system, If applicable, not found. Check during POST.
Page 117
(continued) Table 1-27. Blade Messages Message Causes Corrective Actions Applicable to both base Verify that the PCIe Current Overlimit blade and expansion. expansion cards installed do detected in not have power Expansion NOTE: Applicable to M610x consumption more than only. 250 W.
(continued) Table 1-27. Blade Messages Message Causes Corrective Actions Invalid configuration. The Ensure that the memory Memory system runs but with less modules are installed in a Initialization memory than is physically valid configuration. See Warning: Memory installed. "System Memory" on size may be page 171.
Page 119
(continued) Table 1-27. Blade Messages Message Causes Corrective Actions The memory Reconfigure the memory 128-Bit Advanced configuration does not modules to support ECC Mode Disabled match the setting in BIOS. Advanced ECC mode. See - For 128-Bit The BIOS setting has been "System Memory"...
(continued) Table 1-27. Blade Messages Message Causes Corrective Actions Invalid memory Ensure that the memory MEMTEST lane configuration. A modules are installed in a failure detected mismatched DIMM is valid configuration. See installed. "System Memory" on page 171. Processors with Mismatched processors are Ensure that all processors installed.
Page 121
(continued) Table 1-27. Blade Messages Message Causes Corrective Actions The installed memory Ensure that the memory Alert: DIMM_[m] configuration is invalid. modules are installed in and DIMM_[n] must matched pairs. See "System be populated with Memory" on page 171. a matched set of DIMMs if more than 1 DIMM is present.
(continued) Table 1-27. Blade Messages Message Causes Corrective Actions The installed memory Add, move, or remove Alert! Unsupported configuration is invalid. memory modules to achieve memory, incomplete a configuration supported by sets, or unmatched the system. See "System sets. The Memory"...
Page 123
(continued) Table 1-27. Blade Messages Message Causes Corrective Actions The memory modules are Replace or reseat the DIMMs <A1-A8> not properly seated. memory module(s). See disabled - MemBIST "System Memory" on error. The memory module page 171. connector may be exposed DIMMs <A1-A8>...
Page 124
(continued) Table 1-27. Blade Messages Message Causes Corrective Actions Mismatched or Ensure that all pairs of DIMMs should be unmatched DIMMs memory modules are of the installed in installed; faulty or same type and size and that pairs. Pairs must improperly installed they are properly installed.
Page 125
(continued) Table 1-27. Blade Messages Message Causes Corrective Actions Mismatched or Ensure that all pairs of Error: Incorrect unmatched DIMMs memory modules are of the memory installed; faulty or same type and size, and that configuration. improperly seated memory they are properly installed. DIMMs must be modules.
Page 126
Branch x. or your Dell sales agent to ensure compatibility. Faulty keyboard controller See "Getting Help" on Gate A20 failure. (faulty blade board). page 361.
Page 127
(continued) Table 1-27. Blade Messages Message Causes Corrective Actions Mouse or keyboard cable is Reseat the mouse or Error 8602 - loose or improperly keyboard cable. Ensure that Auxiliary Device connected. the mouse or keyboard is Failure. operational. See Defective mouse or Verify that mouse "Troubleshooting USB keyboard.
Page 128
(continued) Table 1-27. Blade Messages Message Causes Corrective Actions The spacebar or ESC key Information only. Memory tests was pressed during POST terminated by to terminate the memory keystroke. test. Keyboard cable connector Ensure that the keyboard is Keyboard data line loose or improperly properly connected.
(continued) Table 1-27. Blade Messages Message Causes Corrective Actions Faulty or improperly Reseat the mezzanine card. PCI BIOS failed to installed mezzanine card. See "I/O Module Mezzanine install. Cards" on page 217. If the problem persists, see "Getting Help" on page 361. Error encountered in Set the NVRAM_CLR Plug &...
Page 130
Restore the flash memory System service Card flash memory may be using the latest version on update required. corrupted. ftp.dell.com or support.dell.com. See the iDRAC6 User’s Guide for instructions on performing a field replacement of the flash memory. About Your System...
Page 131
(continued) Table 1-27. Blade Messages Message Causes Corrective Actions Faulty memory module. See "Troubleshooting Blade The amount of Memory" on page 319. If the system memory has problem persists, see changed. "Getting Help" on page 361. Unsupported processor(s) Replace the processor(s) This system does installed.
See combination. "Processors" on page 243. Processor is not supported by the blade. Check for a BIOS update using the Dell Support website at support.dell.com. Processor is not supported Check for a BIOS update Unsupported CPU by the blade.
Page 133
Memory" on page 319. faulty DIMMs are disabled: DIMMxx, DIMMyy. Unsupported processor. Update the BIOS firmware Warning! No using the Dell Support microcode update website at support.dell.com. loaded for processor n. There is no memory See "System Memory" on Warning: The configuration error, but page 171.
NOTE: For the full name of an abbreviation or acronym used in this table, see the Glossary at support.dell.com/manuals. Warning Messages A warning message alerts you to a possible problem and prompts you to respond before the system continues a task. For example, before you format a diskette, a message warns you that you may lose all data on the diskette.
NOTE: Warning messages are generated by either the application or the operating system. For more information, see the documentation that accompanied the operating system or application. Diagnostics Messages When you run system diagnostics, an error message may result. Diagnostic error messages are not covered in this section. Record the message on a copy of the Diagnostics Checklist in "Getting Help"...
Using the System Setup Program and UEFI Boot Manager The System Setup program is the BIOS program that enables you to manage your system hardware and specify BIOS-level options. From the System Setup program, you can: • Change the NVRAM settings after you add or remove hardware •...
Entering the System Setup Program 1 Turn on or restart your system. 2 Press <F2> immediately after you see the following message: <F2> = System Setup If your operating system begins to load before you press <F2>, allow the system to finish booting, and then restart your system and try again. Responding to Error Messages If an error message appears while the system is booting, make a note of the message.
System Setup Options NOTE: The options for the System Setup program change based on the system configuration. NOTE: The System Setup program defaults are listed under their respective options, where applicable. Option Description System Time Sets the time on the system's internal clock. System Date Sets the date on the system's internal calendar.
Option Description F1/F2 Prompt on Enables the system to halt on errors during POST, which Error (Enables allows the user to observe events that may scroll by unnoticed default) during normal POST. You can select <F1> to continue or <F2> to enter the System Setup program. CAUTION: When setting this option to Disabled, the system does not halt if an error occurs during POST.
Option Description Redundant Memory If a valid memory configuration is installed, you can enable memory mirroring or spare memory. Options are Mirror (PowerEdge M910, M710HD, and M600) Mode, Spare Mode, and Disabled. NOTE: M710HD systems installed with Intel Xeon 5600 series processors support memory sparing.
Page 142
Option Description If set to Enabled, both logical processors per processor core Logical Processor are enabled. If set to Disabled, only one logical processor (Enabled default) per core is enabled. NOTE: Disable this feature if your system does not run Virtualization Technology (Disabled virtualization software.
Option Description Intel<R> QPI Sets the bandwidth priority to compute. Bandwidth Priority If supported by the processor(s), enables or disables Turbo Turbo Mode Mode. C1E (M915 only) When set to Enabled, the processor switches to minimum performance in the idle state. C States (Enabled When set to Enabled, the processor(s) can operate in all default)
Option Description If Boot Mode is set to BIOS, this field tells the system Boot Sequence where the operating system files needed for startup are located. If Boot Mode is set to UEFI, you can access the UEFI boot manager utility by rebooting the system and pressing F11 when prompted to do so.
Page 145
Option Description Internal SD Card Port Enables or disables the system’s internal SD card port. (PowerEdge M915, NOTE: If a hypervisor is installed, it uses this port. M910, M905, M805, M710, M710HD, M610 and M610x) Redundancy Enables or disables the mirror mode for Internal Dual SD (Disabled default) Module (IDSDM).
Option Description If set to Enabled, the operating system restarts the system OS Watchdog Timer (Disabled default). if it locks up, based on the expiration of a timer. If set to Disabled, in the event of a system lockup, no timer is set and the OS does not restart the system in the event of a lockup.
Option Description Failsafe Baud Rate Displays the failsafe baud rate used for console redirection (115200 default) when the baud rate cannot be negotiated automatically with the remote terminal. Select either VT 100/VT 220 or ANSI. Remote Terminal Type (VT 100/VT 220 default) Redirection After Boot Enables or disables BIOS console redirection after your...
System Security Screen Option Description System Password Displays the current status of the password security feature and allows a new system password assignment and verification. NOTE: For more information, see "Using the System Password" on page 151. Setup Password Restricts access to the System Setup program by using a setup password.
Option Description NOTE: Clearing the TPM loses all encryption keys in the TPM Clear TPM. This option prevents booting to the operating system (No default) and results in data loss if the encryption keys cannot be restored. Back up the TPM keys prior to enabling this option.
Entering the UEFI Boot Manager 1 Turn on or restart your system. 2 Press <F11> after you see the following message: <F11> = UEFI Boot Manager NOTE: The system does not respond until the USB keyboard is active. NOTE: The Boot Mode option in System Setup must be set to UEFI to access the UEFI Boot Manager.
System Utilities Screen Option Description System Setup Accesses the System Setup program without rebooting. System Services Restarts the system and accesses the Unified Server Configurator, which allows you to run utilities such as system diagnostics. For more information, see the Unified Server Configurator User’s Guide.
Page 152
When a system password is not assigned and the password jumper on the system board is in the enabled position, System Password is Not Enabled and Password Status is Unlocked. To assign a system password: 1 Verify that Password Status is Unlocked. 2 Highlight the System Password option and press <Enter>.
To disable the password security: 1 Turn on or reboot your system by pressing <Ctrl><Alt><Del>. 2 Type your password and press <Ctrl><Enter>. When Password Status is Locked, you must type the password and press <Enter> when prompted at reboot. If an incorrect system password is entered, the system displays a message and prompts you to re-enter your password.
Page 154
As you type, placeholders appear in the field. The password assignment is not case-sensitive. Certain key combinations are invalid and if you enter one, the system beeps. To erase a character, press <Backspace> or the left-arrow key. When you verify the password, the Setup Password changes to Enabled. The next time you enter the System Setup program, the system prompts you for the setup password.
Installing Blade Components Recommended Tools You may need the following items to perform the procedures in this section: • #1 and #2 Phillips screwdrivers • T8 and T10 Torx drivers • Wrist grounding strap Removing and Installing a Blade Removing a Blade 1 Power down the blade using OS commands or the CMC, and ensure that the blade's power is off.
Page 156
Figure 3-1. Removing and Installing a Half-Height Blade blade handle release button blade guide rail on M1000e enclosure guide rail on blade (or blade blank) Installing Blade Components...
Page 157
Figure 3-2. Removing and Installing a Full-Height Blade blade handle release button blade guide rail on M1000e enclosure guide rail on blade Installing Blade Components...
Installing a Blade 1 If you are installing a new blade, remove the plastic cover from the I/O connector(s) and save for future use. See Figure 3-3. 2 Orient the blade so that the handle is on the left side of the blade. 3 If you are installing a blade in one of the eight upper bays, align the guide rail on the upper edge of the blade so that the rail fits between the plastic guides on the enclosure.
Installing a Blade Blank 1 Hold the blank with the guide rail facing upwards (see detail in Figure 3-1). 2 Install the blank in the enclosure: • If you are installing a blade blank in one of the eight upper bays, align the metal guide rail on the upper edge of the blade blank so that the guide rail fits between the plastic guides on the enclosure (see detail in Figure 3-1).
Closing the Blade 1 Ensure that no tools or parts are left inside the blade. 2 Align the notches in the edges of the enclosure with the cover alignment pins on the inner sides of the cover. 3 Check that these cover-release latch is fully open, and lower the cover onto the enclosure.
Inside the System Figure 3-4 through Figure 3-12 show the interior components in the blades. Figure 3-4. Inside a Half-Height Blade (PowerEdge M710HD) iDRAC6 enterprise card optional mezzanine card 1 - Fabric C optional mezzanine card 2 - network daughter card Fabric B memory modules (A1 to A9) processor CPU2 and heat sink...
Page 163
Figure 3-5. Inside a Half-Height Blade (PowerEdge M600) optional Fabric C mezzanine card 2 optional Fabric B mezzanine card memory modules processor CPU1 and heat sink hard-drive backplane storage controller card (under drive bays) hard drive 1 hard drive 0 processor CPU2 and heat sink video riser card Installing Blade Components...
System Memory System Memory PowerEdge M915 – The system board has 32 memory sockets organized in four channels per processor with two LV DIMMs per channel. This configuration permits the following maximum memory configurations: 1 GB, 2 GB, 4 GB, 8 GB, and 16 GB LV DIMMs are supported per channel, for a total of up to 512 GB.
Page 173
General Memory Module Installation Guidelines – PowerEdge M915 To ensure optimal performance of your system, observe the following guidelines when configuring your system memory: CAUTION: Memory module blanks must be installed in unoccupied memory sockets to maintain proper cooling airflow. •...
Page 174
Total Number of Memory Modules – Memory Memory Module Locations Physical Processors Number and Type Sparing Memory Support 32 GB Sixteen 2 GB A1, A2, A3, A4, A5, A6, A7, A8, B1, B2, B3, B4, B5, B6, B7, B8 32 GB Four Sixteen 2 GB A1, A2, A3, A4, B1, B2, B3,...
Page 175
Total Number of Memory Modules – Memory Memory Module Locations Physical Processors Number and Type Sparing Memory Support 128 GB Four Thirty two 4 GB A1, A2, A3, A4, A5, A6, A7, A8, B1, B2, B3, B4, B5, B6, B7, B8, C1, C2, C3, C4, C5, C6, C7, C8, D1, D2, D3, D4, D5, D6, D7, D8 192 GB...
Page 176
Total Number of Memory Modules – Memory Memory Module Locations Physical Processors Number and Type Sparing Memory Support 512 GB Four Thirty two 16 GB A1, A2, A3, A4, A5, A6, A7, A8, B1, B2, B3, B4, B5, B6, B7, B8, C1, C2, C3, C4, C5, C6, C7, C8, D1, D2, D3, D4, D5, D6, D7, D8 1 TB...
System Memory – PowerEdge M910 Your system supports DDR3 registered DIMMs (RDIMMS) only. 32 memory sockets are located on the system board, organized in eight channels with four DIMMs per channel. This configuration permits the following maximum memory configurations: Up to four 2 GB, 4 GB, 8 GB, and 16 GB RDIMMs are supported per channel, for a total of up to 512 GB.
Page 179
General Memory Module Installation Guidelines - PowerEdge M910 To ensure optimal performance of your system, observe the following general guidelines when configuring your system memory: • Memory modules must be installed in pairs, beginning with the first two sockets in each set of memory modules. These sockets are marked by white retention levers.
Non-Optimal Memory Configurations System performance can be affected if your memory configuration does not conform to the preceding installation guidelines. Your system may issue an error message during start-up stating that your memory configuration is non- optimal. Memory Sparing Support – PowerEdge M910 Memory sparing (spare bank) is supported in systems that have one of the memory configurations shown in Table 3-3.
Page 182
– Figure 3-15. Memory Locations PowerEdge M905 General Memory Module Installation Guidelines – PowerEdge M905 To ensure optimal performance of your system, observe the following guidelines when configuring your system memory: • Memory modules must be installed in pairs, beginning with the first two sockets in each set of memory modules.
Page 183
• If pairs of memory modules of different sizes are installed, the larger capacity memory modules must be installed in the lower numbered slots. • Memory sparing is supported if 24 memory modules are installed. (Memory mirroring is not supported.) Table 3-4 shows examples of supported memory configurations.
Non-Optimal Memory Configurations System performance can be affected if your memory configuration does not conform to the preceding installation guidelines. Your system may issue an error message during start-up stating that your memory configuration is non- optimal. Memory Sparing Support – PowerEdge M905 Memory sparing (spare bank) is supported in systems that have one of the memory configurations shown in Table 3-5.
Page 185
– Figure 3-16. Memory Locations PowerEdge M805 General Memory Module Installation Guidelines – PowerEdge M805 To ensure optimal performance of your system, observe the following guidelines when installing your system memory: • Memory modules must be installed in pairs of identically-sized DIMMs, beginning with slots A1 and A2 (processor 1) and B1 and B2.
Page 186
• Memory must be installed in the same configuration (symmetrically) for both processors. • If pairs of memory modules of different sizes are installed, the larger capacity memory modules must be installed in the lower numbered slots. • Memory sparing is supported if 16 memory modules are installed. (Memory mirroring is not supported.) Table 3-6 shows examples of supported memory configurations.
Page 187
(continued) Table 3-6. Examples of PowerEdge M805 Memory Configurations Total Memory Modules - Memory Module Locations System Number and Size Memory 64 GB* Eight 8 GB A1, A2, A3, A4, B1, B2, B3, B4 128 GB Sixteen 8 GB A1, A2, A3, A4, A5, A6, A7, A8, B1, B2, B3, B4, B5, B6, B7, B8 *If 64 GB of memory is installed, the system recognizes only 63.75 GB during POST.
System Memory PowerEdge M710 – Your system supports DDR3 registered DIMMs (RDIMMS) or unbuffered DIMMs (UDIMMs). Eighteen memory sockets are located on the system board, organized in three channels with three DIMMs per channel. This configuration permits the following maximum memory configurations: •...
Page 190
General Memory Module Installation Guidelines – PowerEdge M710 To ensure optimal performance of your system, observe the following general guidelines when configuring your system memory: • RDIMMs and UDIMMs cannot be mixed. • Memory modules are populated beginning with the socket farthest from the processor (this socket is indicated by a white socket-release lever).
Page 191
Independent Channel Mode (Optimizer Mode) – PowerEdge M710 In this mode, all three channels are populated with identical memory modules. This mode permits a larger total memory capacity, but does not support the reliability features of the other modes. To enable this mode, select the Optimizer option on the Memory Settings screen of the System Setup program.
Page 192
(continued) Table 3-8. Examples of PowerEdge M710 Memory Configurations Total Memory Modules Memory Module Processors Memory Available Physical – Number and Locations Mode Memory Memory Type 8 GB Four 2 GB A2, A3, B2, B3 Advanced 8 GB UDIMMs 8 GB Four 2 GB A2, A3, A5, A6 Mirroring...
Page 193
(continued) Table 3-8. Examples of PowerEdge M710 Memory Configurations Total Memory Modules Memory Module Processors Memory Available Physical – Number and Locations Mode Memory Memory Type 64 GB Eight 8 GB A2, A3, A5, A6, Advanced 64 GB RDIMMs B2, B3, B5, B6 72 GB Eighteen 4 GB A1, A2, A3, A4,...
System Memory PowerEdge M710HD – Your system supports DDR3 registered DIMMs (RDIMMS). Eighteen memory sockets are located on the system board, organized in three channels per processor with three DIMMs per channel. This configuration supports up to three 2 GB, 4 GB, 8 GB and up to two16 GB RDIMMs per channel, for a total of up to 192 GB.
Page 195
General Memory Module Installation Guidelines – PowerEdge M710HD To ensure optimal performance of your system, observe the following general guidelines when configuring your system memory: • Memory modules are populated beginning with the socket farthest from the processor (this socket is indicated by a white socket-release lever). •...
Page 196
Memory Sparing Support – PowerEdge M710HD NOTE: For memory sparing support, your system must be installed with Intel Xeon 5600 series processors. Memory sparing (spare bank) is supported in systems that have one of the memory configurations shown in Table 3-9. The memory sparing feature must also be enabled in the Memory Information screen of the System Setup program.
Page 197
(continued) Table 3-9. Examples of PowerEdge M710HD Memory Configurations Total Memory Modules Memory Module Processors Memory Available Physical – Number and Locations Mode Memory Memory Type 4 GB Four 1 GB A2, A3, B2, B3 Mirroring 2 GB UDIMMs 4 GB Four 1 GB A2, A3, B2, B3 Advanced...
Page 198
(continued) Table 3-9. Examples of PowerEdge M710HD Memory Configurations Total Memory Modules Memory Module Processors Memory Available Physical – Number and Locations Mode Memory Memory Type 32 GB Eight 4 GB A2, A3, A5, A6, Advanced 32 GB RDIMMs B2, B3, B5, B6 36 GB Nine 4 GB A1, A2, A3, A4,...
– Figure 3-19. Memory Locations PowerEdge M610/M610x Channel 2 (A1, A4) Channel 1 (A2, A5) Channel 0 (A3, A6) CPU2 CPU1 Channel 0 (B3, B6) Channel 1 (B2, B5) Channel 2 (B1, B4) General Memory Module Installation Guidelines – PowerEdge M610/M610x To ensure optimal performance of your system, observe the following general guidelines when configuring your system memory: •...
Page 201
Three memory channels are allocated to each processor. The number of channels used and the allowable configurations depend on the memory mode selected. The channels are organized as follows: • Channel 0 - sockets 3, 6 • Channel 1 - sockets 2, 5 •...
Page 202
Independent Channel Mode (Optimizer Mode) – PowerEdge M610/M610x In this mode, all three channels are populated with identical memory modules. This mode permits a larger total memory capacity, but does not support the reliability features of the other modes. To enable this mode, select the Optimizer option on the Memory Settings screen of the System Setup program.
Page 203
(continued) Table 3-10. Examples of PowerEdge M610/M610x Memory Configurations Total Memory Modules Memory Module Processors Memory Available Physical – Number and Locations Mode Memory Memory Type 8 GB Four 2 GB A2, A3, B2, B3 Advanced 8 GB UDIMMs 8 GB Four 2 GB A2, A3, A5, A6 Mirroring...
(continued) Table 3-10. Examples of PowerEdge M610/M610x Memory Configurations Total Memory Modules Memory Module Processors Memory Available Physical – Number and Locations Mode Memory Memory Type 96 GB Twelve 8 GB A1, A2, A3, A4, Independent 96 GB RDIMMs A5, A6, B1, B2, channel B3, B4, B5, B6 128 GB...
Page 205
– Figure 3-20. Memory Locations PowerEdge M605 General Memory Module Installation Guidelines – PowerEdge M605 To ensure optimal performance of your system, observe the following guidelines when installing your system memory: • Memory modules must be installed in pairs of identically-sized DIMMs, beginning with slots A1 and A2 (processor 1) and B1 and B2 (processor 2, if installed).
Page 206
Single-Processor Memory Configurations CAUTION: Memory module blanks must be installed in unoccupied memory sockets to maintain proper cooling airflow. – Table 3-11. Single-Processor Memory Configurations PowerEdge M605 Total CPU 1 System Memory 1 GB 512 MB 512 MB blank blank 2 GB 512 MB 512 MB...
Page 207
Dual-Processor Memory Configurations CAUTION: Memory module blanks must be installed in unoccupied memory sockets to maintain proper cooling airflow. – Table 3-12. Dual-Processor Memory Configurations PowerEdge M605 Total CPU1 CPU2 System Memory 2 GB 512 MB 512 MB blank blank 512 MB 512 MB blank blank 4 GB...
Page 208
Non-Optimal Memory Configurations System performance can be affected if your memory configuration does not conform to the preceding installation guidelines. Your system may issue an error message during start-up stating that your memory configuration is non- optimal. Memory Sparing Support – PowerEdge M605 Memory sparing is supported in single- or dual-processor systems that have one of the fully populated memory configurations shown in Table 3-13.
System Memory PowerEdge M600 – You can upgrade your system memory to a maximum of 32 GB by installing 667 MHz registered DDRII fully-buffered DIMMs (FBDs). 512 MB, 1 GB, 2 GB, 4 GB, and 8 GB memory modules are supported. The memory module sockets are divided into two equal branches (0 and 1).
Page 211
General Memory Module Installation Guidelines – PowerEdge M600 To ensure optimal performance of your system, observe the following guidelines when configuring your system memory: • Memory modules must be installed in pairs of identically-sized DIMMs. The total number of memory modules must equal two, four, or eight. Six modules are not supported.
Page 212
Non-Optimal Memory Configurations System performance can be affected if your memory configuration does not conform to the preceding installation guidelines. Your system may issue an error message during start-up stating that your memory configuration is non- optimal. Memory Sparing Support – PowerEdge M600 Memory sparing requires eight identical memory modules.
Installing Memory Modules WARNING: The memory modules are hot to the touch for some time after the blade has been powered down. Allow time for the memory modules to cool before handling them. Handle the memory modules by the card edges and avoid touching the components.
6 Align the memory module's edge connector with the alignment key on the memory module socket, and insert the memory module in the socket. NOTE: The memory module socket has an alignment key that allows you to install the memory module in the socket in only one way. 7 Press down on the memory module with your thumbs to lock the memory module into the socket.
4 PowerEdge M910 and M905 systems only - You must slide the system board back in the blade chassis to access memory sockets (B1-B8) and (D1-D8) for M910 and (C1-C4) and (D1-D4) for M905. See step 1 through step 9 in "Removing the System Board"...
Installing the Mezzanine Interface Card 1 Remove the blade. See "Removing a Blade" on page 155. 2 Open the blade. See "Opening the Blade" on page 159. 3 Open the card retention latch by pressing the ridged area on the latch with your thumb and lifting the end of the latch.
Mezzanine Card Installation Guidelines Full-Height Blades Full-height blades support up to four mezzanine cards. NOTE: Even though PowerEdge M610x is a full blade system, only two mezzanine card slots (MEZZ1_Fab_C1 and MEZZ2_FAB_B1) in the expansion bay are available for use. The other two slots on the system board (MEZZ1_FAB_C and MEZZ2_FAB_B) are occupied by the mezzanine interface card which provides connectivity between the PCIe expansion-card riser and the system board.
• PowerEdge M610x supports two small-form factor (SFF) mezzanine cards. x8 PCIe Gen 1 and x8 PCIe Gen 2 cards are supported. Half-Height Blades Half-height blades support two mezzanine cards: • Mezzanine card slot C supports Fabric C. This card must match the fabric type of I/O modules installed in I/O module bays C1 and C2.
Page 220
Figure 3-24. Installing and Removing a Mezzanine Card - Full-Height Blades optional Fabric C mezzanine card 1 optional Fabric B mezzanine card 2 optional Fabric C mezzanine card 3 optional Fabric B mezzanine card 4 retention latch mezzanine card connector mezzanine card Installing Blade Components...
Page 221
Figure 3-25. Installing and Removing a Mezzanine Card - Half-Height Blades Fabric C mezzanine card slot Fabric B mezzanine card slot mezzanine card mezzanine card connector retention latch 4 If present, remove the connector cover from the mezzanine card bay. NOTE: Hold the mezzanine card by its edges only.
6 Lower the card into place until it is fully seated and the plastic clip on the outer edge of the card fits over the side of the blade chassis. 7 Close the retention latch to secure the mezzanine card. 8 Close the blade.
SD Card PowerEdge M905 and M805 In these blades, the SD card is an unmanaged persistent storage card. A hypervisor may be installed using this card. 1 Remove the blade. See "Removing a Blade" on page 155. 2 Install the SD card in the lower card slot. See Figure 3-26. 3 Install the blade.
PowerEdge M915, M910, M710, M710HD, M610, and M610x In these blades, the SD card is an unmanaged persistent storage card. A hypervisor may be installed using this card. NOTE: For PowerEdge M915, M910, and M710HD, the iDRAC6 vFLASH card can be set to IDSDM function along with the SD card by setting the Redundancy option to Mirror mode in the Integrated Devices screen of system setup.
SD vFlash Card (PowerEdge M915, M910, M710, M710HD, M610, and M610x Only) NOTE: For PowerEdge M915, M910 and M710HD, the iDRAC6 vFLASH card can be set to IDSDM function along with the SD card by setting the Redundancy option to Mirror mode in the Integrated Devices screen of system setup.
RAID Battery The information in this section applies only to systems with the optional PERC controller cards without an integral battery backup unit. NOTE: For PowerEdge M710, M610, and M610x the RAID battery connectors are located on the system board. To locate the connectors for the RAID battery on the system board, see the appropriate figure in "System Board Connectors"...
Installing the RAID Battery 1 Insert the battery. For systems with a battery carrier: Insert the RAID battery into the battery carrier. See Figure 3-29. Align the tabs on the battery carrier with the battery carrier slots on the chassis. Slide the battery carrier into the battery carrier slots until it locks into place.
Integrated NIC Hardware Key Hardware functionality for the blade’s integrated NICs is enabled by installing a NIC hardware key in the socket on the system board (see "System Board Connectors" on page 338.) NOTE: Operating system support is also required for full NIC functionality. Figure 3-33.
To boot from the USB memory key, you must configure the USB memory key with a boot image, and then specify the USB memory key in the boot sequence in the System Setup program. See "Boot Settings Screen" on page 143. For information on creating a bootable file on the USB memory key, see the user documentation that accompanied the USB memory key.
4 Lift the card from the system board. 5 Close the blade. See "Closing the Blade" on page 161. 6 Install the blade. See "Installing a Blade" on page 158. Figure 3-35. Removing or Installing the Integrated Network Card screw (3) LOM riser card LOM riser card connector Installing the LOM Riser Card...
4 Tighten the screws to secure the card to the system board. See Figure 3-35. 5 Close the blade. See "Closing the Blade" on page 161. 6 Install the blade. See "Installing a Blade" on page 158. Expansion Cards and Expansion-Card Riser (PowerEdge M610x Only) Expansion Card Installation Guidelines Your system supports up to two Generation 2 PCIe expansion cards installed...
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Page 240
Figure 3-37. Installing or Removing Cables Connecting the Expansion-Card Riser to the Mezzanine Interface Card (PowerEdge M610x Only) mezzanine interface card cable management clip data cable 2 data cable 1 data cable connector 2 data cable connector 1 expansion-card riser Installing Blade Components...
Page 241
Figure 3-38. Installing or Removing Cables Connecting the Expansion-Card Riser to the Midplane Interface Card (PowerEdge M610x Only) midplane interface card data cable 4 power cable connecting midplane expansion-card riser interface card to expansion-card riser expansion card power cables connecting midplane interface card to expansion cards (2) NOTE: You may use both power...
Page 242
4 Lift up on the left side of the impedance wall to release it from the chassis inner wall, then slide the impedance wall out of the slot on the expansion- card riser. See Figure 3-36. 5 Lift the expansion-card riser off the riser guide posts and out of the system. See Figure 3-39.
Installing the Expansion-Card Riser 1 Align the riser guides on each end of the expansion-card riser with the riser guide posts on the system board and lower the riser into the blade until the riser is fully seated on the system board. See Figure 3-39. 2 If applicable, reinstall the expansion card(s).
PowerEdge M805 System • PowerEdge M805 supports dual-core or quad-core AMD Opteron 2xxxx series processors only. • Two processors must be installed; single-processor configurations are not supported. • Hypertransport (HT) bridge cards must be installed in sockets CPU3 and CPU4. See "HT Bridge Card (PowerEdge M905 Only)" on page 262. PowerEdge M710, M710HD, M610, M610x, and M600 Systems •...
Page 245
Figure 3-40. Installing and Removing the Heat Sink (PowerEdge M915) heat sink screws (4) NOTE: You must install the heat sink in the orientation shown here. processor 4 processor 2 processor 3 processor 1 Installing Blade Components...
Page 246
Figure 3-41. Installing and Removing the Heat Sink (PowerEdge M910) NOTE: The above illustration shows the 130 W heat sink. The 95 W / 105 W heat sinks look similar to the heat sink shown in Figure 3-42. heat sink screws (4) NOTE: You must install the heat sink in...
Page 247
Figure 3-42. Installing and Removing the Heat Sink (PowerEdge M905) heat sink screws (4) NOTE: You must install the heat sink in the orientation shown here. socket CPU2 socket CPU4 socket CPU3 socket CPU1 Installing Blade Components...
Page 248
Figure 3-43. Installing and Removing a Heat Sink (PowerEdge M805) heat sink screws (4) NOTE: You must install the heat sink in the orientation shown here. socket CPU2 socket CPU1 Installing Blade Components...
Page 249
Figure 3-44. Installing and Removing a Heat Sink (PowerEdge M710) heat sink screws (4) NOTE: You must install the heat sink in the orientation shown here. socket CPU2 socket CPU1 Installing Blade Components...
Page 250
Figure 3-45. Installing and Removing a Heat Sink (PowerEdge M710HD) socket CPU2 screws (2) heat sink socket CPU1 NOTE: You must install the heat sink in the orientation shown here. Installing Blade Components...
Page 251
Figure 3-46. Installing and Removing a Heat Sink (PowerEdge M610) socket CPU2 heat sink NOTE: You must install the heat sink in the orientation shown here. screws (4) socket CPU1 Installing Blade Components...
Page 252
Figure 3-47. Installing and Removing a Heat Sink (PowerEdge M610x) heat sink screws (4) NOTE: You must install the heat sink in the orientation shown here. socket CPU2 socket CPU1 Installing Blade Components...
Page 254
Figure 3-49. Installing and Removing a Heat Sink (PowerEdge M605) heat sink screws (4) socket CPU2 socket CPU1 4 Remove the heat sink. Set the heat sink upside down on the work surface to avoid contaminating the thermal grease. 5 Use a clean, lint-free cloth to remove any thermal grease from the surface of the processor shield.
Page 255
6 For PowerEdge M910, remove the screw to release the processor shield and then lift the processor out of the socket. See Figure 3-51. For other blades, pull the socket-release lever straight up until the processor is released from the socket. Open the processor shield and then lift the processor out of the socket.
Page 256
processor notch in processor screw pin-1 corner of processor processor shield pin-1 corner of socket socket-release lever Figure 3-51. Installing and Removing an Intel Processor (PowerEdge M910) processor screw processor shield pin-1 corner of socket notch in processor Installing Blade Components...
Page 257
Figure 3-52. Installing and Removing an Intel Processor (PowerEdge M710, M710HD, M610, M610x, or M600) socket-release lever processor processor shield notch in processor pin-1 corner of socket pin-1 corner of processor Installing Blade Components...
Page 258
Figure 3-53. Installing and Removing an AMD Processor (PowerEdge M905, M805, or M605) pin-1 corner of socket pin-1 corner of processor processor socket-release lever processor shield notch in processor Installing Blade Components...
Installing a Processor 1 If you are adding a processor to an unoccupied socket, perform the following steps first: NOTE: If you are installing just one processor, it must be installed in socket CPU1. See Figure 7-13 or Figure 7-12. Remove the processor filler blank.
Page 260
For PowerEdge M910, tighten the screw securing the processor shield. For other blades, rotate the socket release lever down until it snaps into place, securing the processor. 3 Install the heat sink: If you are reinstalling a heat sink, use a clean, lint-free cloth to remove the existing thermal grease from the heat sink.
7 Run the system diagnostics to verify that the new processor operates correctly. See "Running System Diagnostics" on page 325 for information about running the diagnostics and troubleshooting processor problems. 8 Update the system BIOS. FlexMem Bridge (PowerEdge M910 Only) A FlexMem bridge must be installed in the third or fourth CPU sockets on the PowerEdge M910 system board to support two-processor configurations.
2 Install the FlexMem Bridge in the socket. CAUTION: Positioning the card incorrectly can permanently damage the card and the system board when you turn on the system. Be careful not to bend the pins on the LGA socket. Identify the pin-1 corner of the card by locating the tiny gold triangle on one corner of the card.
Page 263
Figure 3-54. Installing and Removing an HT Bridge Card (PowerEdge M905 Only) socket-release lever processor shield notch in card HT bridge card Installing Blade Components...
Page 264
Installing an HT Bridge Card 1 Perform the following steps to prepare the two sockets on the new system board: Remove the processor filler blank. Lift the plastic processor socket cover from the socket. Unlatch and rotate the socket-release lever 90 degrees upward. Lift the processor shield.
Blade System Board NVRAM Backup Battery The NVRAM backup battery is a 3.0 V, coin-cell battery. Removing and Installing the NVRAM Backup Battery WARNING: There is a danger of a new battery exploding if it is incorrectly installed. Replace the battery only with the same or equivalent type recommended by the manufacturer.
Page 266
Figure 3-55. Replacing the NVRAM Backup Battery "+" side of battery battery connector 6 If you removed the system board to replace the battery, reinstall the board now. See "Blade System Board" on page 276. 7 Close the blade. See "Closing the Blade" on page 161. 8 Install the blade.
Hard Drives • PowerEdge M915 supports two 2.5 inch SAS or SSD hard-disk drives. • PowerEdge M910 supports up to two 2.5 inch SAS, SATA, or solid-state disk (SSD) hard drives. • PowerEdge M905 and M805 support one or two 2.5 inch SAS hard-disk drives.
Page 268
Figure 3-56. Installing a Hard Drive release button hard drive carrier handle 2 Insert the hard-drive carrier into the drive bay. Carefully align the channel on the hard-drive carrier with the appropriate drive slot on the blade. 3 Push the drive carrier into the slot until the handle makes contact with the blade.
Removing a Hard Drive NOTE: Not all operating systems support hot-swappable drive installation. See the documentation supplied with your operating system. 1 Take the hard drive offline and wait until the hard-drive indicator codes on the drive carrier signal that the drive may be removed safely. See Figure 1-14.
Installing a Hard Drive in a Hard-Drive Carrier 1 Insert the hard drive into the hard-drive carrier with the drive’s controller board’s connector end of the drive at the back of the carrier. See Figure 3-57. 2 From the back of the carrier, slide the drive into the carrier until it contacts the stop tab on the front of the carrier.
Page 271
Figure 3-57. Removing and Installing a Hard Drive in a Hard-Drive Carrier hard drive hard-drive carrier screws (4) Installing Blade Components...
Video Controller (PowerEdge M905, M805, M605, and M600 Only) Follow these steps to remove and replace the video controller: 1 Remove the blade. See "Removing a Blade" on page 155. 2 Open the blade. See "Opening the Blade" on page 159. 3 Remove the video controller: •...
Page 273
Figure 3-59. Removing and Installing a Video Controller Daughter Card (PowerEdge M605 Shown) video controller board torx screws (2) connector on system board 4 To install a new video controller: If you are installing a video controller in a PowerEdge M600, align the •...
Hard-Drive Backplane NOTE: A hard-drive backplane must be installed in each blade to maintain proper airflow, even when the blade is in a diskless configuration. NOTE: PowerEdge M600, M610, M610x, M710, M710HD, M805, M905, and M910 have one hard-drive backplane and PowerEdge M915 has two hard-drive backplanes.
Page 275
Figure 3-60. Removing and Installing the Hard-Drive Backplane (M915 Shown) hard-drive backplane (2) hard-drive connectors (2) retention hooks (4) latches (4) backplane connector (2) 5 To install the hard-drive backplane: Hold the backplane with the drive connectors facing towards the hard drive bays.
6 Replace the hard drive(s). If you are installing multiple drives, be sure to reinstall them in their original locations. 7 Close the blade. See "Closing the Blade" on page 161. 8 Install the blade. See "Installing a Blade" on page 158. Blade System Board Removing the System Board 1 Remove the blade.
Page 277
NOTE: If you are removing multiple mezzanine cards, label them so that you can replace them in their original locations. 9 To remove a full-height blade system board: Use the thumb and index fingers of your right hand to lift the system board retention pin.
Page 278
Figure 3-61. Removing and Installing a System Board (Full-Height Blades – PowerEdge M905 Shown) system board system board retention pin tabs on system chassis slots in system board tray Installing Blade Components...
Page 279
To remove a half-height blade system board, hold the blade chassis with one hand, lift and pull the system board retention latch with the other hand, and then slide the system board out of the open end of the chassis. See Figure 3-62.
11 Remove the video riser card or daughter card. See "Video Controller (PowerEdge M905, M805, M605, and M600 Only)" on page 272. 12 Remove the memory modules and memory module blanks. See "Removing Memory Modules" on page 214. 13 Remove the processor(s). See "Removing a Processor" on page 244. 14 Remove the storage controller board.
2 Slide the new system board into the open end of the blade chassis until the retention latch or retention pin engages. NOTE: Ensure that the system board plate is parallel with the chassis. When the board assembly is installed correctly, the tabs on the system board pan fit into the corresponding openings in the floor of the blade chassis.
5 If you are removing a RAID controller, disconnect the RAID battery from the controller board. 6 Lift the controller board straight up from the system board. Figure 3-63. Removing and Installing the Storage Controller Card (Half-Height Blade Shown) storage controller card release lever Installing the Storage Controller Board 1 To place the storage controller board onto the system board, align the...
4 Reinstall the system board. See "Installing the System Board" on page 280. 5 Install the blade. See "Installing a Blade" on page 158. Midplane Interface Card (PowerEdge M610x) The midplane interface card is an additional chassis option that provides the capability to use PCIe cards.
Page 284
Figure 3-64. Removing and Installing the Midplane Interface Card - PowerEdge M610x screws (2) power cable connectors (3) midplane interface card data cable connectors (2) 6 Disconnect the power and data cables from the connectors on the midplane interface card. To disconnect the power and data cables, press the release latch on the connector, push inward slightly, then outward to release the cable connector from the board connector.
8 Slide the midplane interface card toward the back of the chassis and lift it out of the chassis. Installing the Midplane Interface Card 1 Position the midplane interface card into the blade chassis by sliding it in from the back of the chassis. 2 Tighten the screws that secure the midplane interface card to the chassis.
(chassis, servers, I/O modules, iKVM, CMC, and power supplies). The power management service optimizes power consumption and re-allocates power to different modules based on real-time demand. For more information, see "Power Management" in the Dell Chassis Management Controller User’s Guide. NOTE: The wattage of a power supply module is listed on its regulatory label.
NOTE: PDU inlet cords for this system may be too thick to fit in the wire guides installed in the rack vertical rails. If this is the case, remove the wire guides by removing the attachment screw securing each guide. Route the PDU inlet cords along the vertical rails, securing them with tie wraps or Velcro strips.
Page 289
Figure 4-1. Power Cable Retention Clip power supply retention clip tether notch in power supply handle retention clip power cable 2 Press down on the power supply module release button on the handle. See Figure 4-2. Installing Enclosure Components...
Page 290
Figure 4-2. Removing and Installing a Power Supply Module power supply handle release button 3 Rotate the power supply module handle down to eject the power supply module. 4 Slide the power supply module out of the enclosure. Installing Enclosure Components...
Installing a Power Supply Module 1 Ensure that the power supply module handle is fully open and the power cable is not plugged into the electrical outlet. 2 Slide the power supply module into the enclosure. See Figure 4-2. 3 Rotate the power supply module handle upward until it latches. 4 Plug a power cable into the power supply module.
Figure 4-3. Removing and Installing a Fan Module fan module release button Installing a Fan Module 1 Inspect the fan for debris before installing the fan in the enclosure. 2 Slide the fan module into the enclosure until it is fully seated and the release button engages.
CMC Module Removing a CMC Module 1 Disconnect the cables attached to the CMC module. 2 Push the release latch on the handle and rotate the handle away from the module front panel. 3 Slide the CMC module out of the enclosure. 4 Install the I/O connector cover.
Installing an SD Card in the CMC Module The SD card slot on the CMCM module supports an optional WWN/MAC feature that allows slot-based WWN/MACs for the blades, simplifying blade installation and replacement. NOTE: For a redundant CMC module system, install the SD card on the passive module.
3 Reinstall the CMC module and reattach any cables that were disconnected. See "Installing a CMC Module" on page 295. On a single CMC system, the SD card activates automatically. For redundant CMC module systems, initiate a changeover to make the passive module active using the following steps: 1 Navigate to the Chassis page.
iKVM Module Removing an iKVM Module 1 Disconnect the cables attached to the iKVM module. 2 Press in the release latch on the handle and rotate the handle away from the module front panel. See Figure 4-4. 3 Slide the module out of the enclosure. Installing an iKVM Module 1 Ensure that the module handle is fully open.
Installing an I/O Module NOTE: The I/O module must be installed in the appropriate I/O bay. See "Guidelines for Installing I/O Modules" on page 52. 1 Unpack the I/O module and prepare it for installation. For instructions, see the documentation that accompanied the I/O module.
Figure 4-7. Removing and Installing the Bezel bezel enclosure screws (8) Installing the Enclosure Bezel 1 Attach the bezel to the enclosure using the screws. See Figure 4-7. 2 Connect the ribbon cable to the LCD module, and reinstall the cover plate.
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Page 301
Figure 4-8. Removing and Installing the Front Module Cage Assembly front module cage assembly enclosure screws (4) NOTE: The empty cage assembly weighs 21 kg (47 lbs). Obtain assistance when removing the cage assembly from the enclosure. 9 Slide the cage out from the enclosure. See Figure 4-8. 10 Disconnect the control-panel cable from the midplane by pressing the small latch at each end of the connector.
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Page 304
Figure 4-10. Removing and Installing the Control Panel control panel control-panel cable screws (2) LCD panel cable 5 Press the catch at each end of the control-panel cable connector, and remove the control-panel cable from the underside of the control panel. 6 Use the pull-tab to disconnect the LCD panel cable from the underside of the control panel.
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Page 306
Figure 4-11. Removing and Installing the LCD Module cable cover LCD module ribbon cable hinges (2) screws (2) 2 Remove the cable cover. 3 Disconnect the ribbon cable. 4 Remove the two screws securing the LCD module to the hinges. Installing Enclosure Components...
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Checking the Equipment This section provides troubleshooting procedures for external devices attached to the system, such as the monitor, keyboard, or mouse. Before you perform any of the procedures, see "Troubleshooting External Connections" on page 310. Troubleshooting External Connections Loose or improperly connected cables are the most likely source of problems for the system, monitor, and other peripherals (such as a keyboard, mouse, or other external device).
Troubleshooting the Keyboard 1 Ensure that the blade(s) is turned on. 2 Verify that the iKVM firmware revision is current. 3 Check the keyboard connection to either the front-panel connector on the blade or to the back-panel iKVM module. 4 If the keyboard is connected to an external KVM using a SIP, check that the SIP is compatible with the KVM.
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
6 Remove the CMC module(s). See "Removing a CMC Module" on page 293. 7 Remove the iKVM module. See "Removing an iKVM Module" on page 296. 8 Remove the I/O modules. See "Removing an I/O Module" on page 296. 9 Let the system dry thoroughly for at least 24 hours. 10 Install the I/O modules.
3 Ensure that all components are properly installed and free from damage. 4 Run the online diagnostics. See "Running System Diagnostics" on page 325. If the tests fail, see "Getting Help" on page 361. Troubleshooting Enclosure Components The following procedures describe how to troubleshoot the following components: •...
1 Verify that the latest firmware is installed on the CMC module. See support.dell.com for the latest firmware and refer to the release notes for firmware compatibility and update information. 2 Verify that the CMC(s) have valid IP addresses for the subnet. Verify using the ICMP ping command.
Page 316
3 Reseat the CMC module and see if the CMC module fault indicator turns off. See "CMC Module" on page 293 and Figure 1-22 for more information about the module’s indicators. 4 If another CMC module is available, swap the two modules. 5 If the fault indicator is off, but the serial device connected to the serial port is not properly operating, go to step 6.
Troubleshooting the iKVM Module Problem: When using iDRAC video\console redirection you cannot see video through the iKVM when you switch to a blade running Linux. Likely Cause and Solution: A monitor or KVM appliance with a lower resolution has recently been added. Example: A blade running X Windows under Linux is inserted and powered on.
Troubleshooting a Network Switch Module NOTE: To eliminate the possibility of a hardware problem with the module or its attaching devices, first ensure that the module is properly initialized and configured. See the Configuration Guide and the documentation that came with the module before performing the following procedure.
Troubleshooting Blade Components The following procedures describe how to troubleshoot the following components. See Figure 3-5 for the location of the components inside the blade. • Memory • Hard drives • Expansion cards • Processors • Blade system board • Battery Troubleshooting Blade Memory NOTE:...
6 Close the blade. See "Closing the Blade" on page 161. 7 Install the blade. See "Installing a Blade" on page 158. 8 Run the system memory test in the system diagnostics. See "Running System Diagnostics" on page 325. If the test fails, see "Getting Help" on page 361. Troubleshooting Hard Drives CAUTION: This troubleshooting procedure can destroy data stored on the hard...
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
14 For each expansion card you removed in step 10, perform the following steps: Open the blade. See "Opening the Blade" on page 159. Reinstall one of the expansion cards. Close the blade. See "Closing the Blade" on page 161. Install the blade and turn it on.
Troubleshooting the Blade Board 1 Remove the blade. See "Removing a Blade" on page 155. 2 Open the blade. See "Opening the Blade" on page 159. 3 Clear the blade NVRAM. See "Blade System Board Jumper Settings" on page 331 for the location of the NVRAM_CLR jumper.
Troubleshooting the NVRAM Backup Battery Each blade contains a battery that maintains the blade configuration, date, and time information in NVRAM when you turn off the blade. You may need to replace the battery if an incorrect time or date is displayed during the boot routine.
Dell PowerEdge Diagnostics To assess a system problem, first use the online Dell PowerEdge Diagnostics. Dell PowerEdge Diagnostics is a suite of diagnostic programs, or test modules, that include diagnostic tests on chassis and storage components such as hard drives, physical memory, communications ports, NICs, CMOS, and more.
3 To exit the utility, reboot the system and press <F10> to re-enter USC or USC-LCE. The results of the diagnostics tests are displayed on the screen when the tests are complete. To resolve the problems found in the test results, search the resolutions from support.dell.com. Running System Diagnostics...
8 Ensure that you have the USB flash drive connected to the blade. 9 Reboot the blade. If the blade fails to boot, see "Contacting Dell" on page 361. When you start the system diagnostics, a message is displayed stating that the diagnostics are initializing.
System Diagnostics Testing Options To select an option from the Diagnostics menu, highlight the option and press <Enter>, or press the key that corresponds to the highlighted letter in the option. Table 6-1 provides a brief explanation of testing options. Table 6-1.
When you run a system diagnostics test, you may receive an error message during testing. Record the message on a copy of the Diagnostics Checklist. For a copy of the Diagnostics Checklist and instructions for obtaining technical assistance, see "Contacting Dell" on page 361. Running System Diagnostics...
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
PowerEdge M910 Jumper Settings Figure 7-3 shows the location of the configuration jumpers on the blade system board. Table 7-2 lists the jumper settings. NOTE: Figure 7-3 is oriented with the front end of the blade system board facing to the right.
(continued) Table 7-3. PowerEdge M905 Jumper Settings NVRAM_CLR (default) The configuration settings are retained at system boot. The configuration settings are cleared at the next system boot. (If the configuration settings become corrupted to the point where the system does not boot, install the jumper and boot the system.
PowerEdge M710 Jumper Settings Figure 7-5 shows the location of the configuration jumpers on the blade system board. Table 7-5 lists the jumper settings. NOTE: Figure 7-5 is oriented with the front end of the blade system board facing to the right.
PowerEdge M710HD Jumper Settings Figure 7-6 shows the location of the configuration jumpers on the blade system board. Table 7-6 lists the jumper settings. NOTE: Figure 7-6 is oriented with the front end of the blade system board facing to the right.
PowerEdge M610/M610x Jumper Settings Figure 7-7 shows the location of the configuration jumpers on the blade system board. Table 7-7 lists the jumper settings. NOTE: Figure 7-7 is oriented with the front end of the blade system board facing to the right.
PowerEdge M600 Jumper Settings Figure 7-13 shows the location of the configuration jumpers on the blade system board. Table 7-8 lists the jumper settings. NOTE: Figure 7-13 is oriented with the front end of the blade system board facing to the right.
PowerEdge M910 System Board Figure 7-2. PowerEdge M910 System Board Connectors Table 7-10. PowerEdge M910 System Board Connectors Connector Description J_INT_USB USB connector CPU2 Processor 2 socket CPU4 Processor 4 socket B1 – B8 Memory modules B1 – B8 Optional RAID battery System Board Information...
Page 341
(continued) Table 7-10. PowerEdge M910 System Board Connectors Connector Description D1 – D4 Memory modules D1 – D4 Connector for the 3.0 V coin battery NOTE: Access requires removal of system board. See "Removing the System Board" on page 276. J_STORAGE Storage controller card connector C1 –...
PowerEdge M905 System Board Figure 7-3. PowerEdge M905 System Board Connectors Table 7-11. PowerEdge M905 System Board Connectors Connector Description MEZZ4_FAB_B Mezzanine card connector 4 Fabric B SD card connector System board retention pin B1 – B8 Memory modules B1 – B8 CPU2 Processor 2 socket D1 –...
Page 343
(continued) Table 7-11. PowerEdge M905 System Board Connectors Connector Description C1 – C4 Memory modules C1 – C4 PSWD_EN, System configuration jumpers NVRAM_CLR NOTE: Access requires removal of system board. See "Removing the System Board" on page 276. 10 - Connector for the 3.0 V coin battery NOTE: Access requires removal of system board.
PowerEdge M805 System Board Figure 7-4. PowerEdge M805 System Board Connectors Table 7-12. PowerEdge M805 System Board Connectors Connector Description MEZZ4_FAB_B Mezzanine card connector 4 Fabric B SD card connector System board retention pin B1 – B8 Memory modules B1 – B8 CPU2 Processor 2 socket System Board Information...
Page 345
(continued) Table 7-12. PowerEdge M805 System Board Connectors Connector Description PWRD_EN, System configuration jumpers NVRAM_CLR NOTE: Access requires removal of system board. See "Removing the System Board" on page 276. Connector for the 3.0 V coin battery NOTE: Access requires removal of system board. See "Removing the System Board"...
PowerEdge M710 System Board Figure 7-5. PowerEdge M710 System Board Connectors Table 7-13. PowerEdge M710 System Board Connectors Connector Description MEZZ4_FAB_B Mezzanine card connector 4 Fabric B System board retention pin B1 – B9 Memory modules B1 – B9 CPU2 Processor 2 socket ISCSI_KEY Hardware key socket for integrated NIC feature...
Page 347
(continued) Table 7-13. PowerEdge M710 System Board Connectors Connector Description J_INT_USB USB connector Connector for the 3.0 V coin battery NOTE: Access requires removal of system board. See "Removing the System Board" on page 276. 10 J_STORAGE Storage controller card connector 11 PWRD_EN, System configuration jumpers NVRAM_CLR...
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Page 359
6 Close the blade. See "Closing the Blade" on page 161. 7 Install the blade. See "Installing a Blade" on page 158. When the blade is on, the power-on indicator is solid green. Allow the blade to finish booting. The existing passwords are not disabled (erased) until the system boots with the password removed.
NOTE: If you do not have an active Internet connection, you can find contact information on your purchase invoice, packing slip, bill, or Dell product catalog. Dell provides several online and telephone-based support and service options. Availability varies by country and product, and some services may not be available in your area.