Your compactor has been designed to require minimum
space without loss of capacity whether free-standing or
built-in.
Free Standing
As shipped, the Compactor is only configured for built in
installations. This appliance can be converted from built-
in to free-standing with the use of Toe Kick Accessory
Kit Model ETC15TKH (sold separately). If additional cord
length is required for free-standing installation, remove
the cord clamp and wire tie on the back of the unit.
caution: Failure to use Toe Kick Accessory Kit Model
ETC15TKH in a free-standing installation may cause the
compactor to be unstable during operation.
Built-in Installations
mounting straps
TOP OF
COMPACTOR
FRONT OF
COMPACTOR
Two under-counter mounting straps are provided. Use
these straps to secure the compactor to the underside of
a countertop. Fasten the slotted end of the straps to the
compactor using the holes in the top of the compactor
cabinet as shown.
NOTE: When installing compactor under granite or solid-
surface countertops, bend the mounting straps so they
can be secured to the adjacent cabinetry.
undEr-countEr opEning
15" W
34
5
/
" H
8
ELECTRICAL
OUTLET
Opening
15" Wide
1" MIN.
34-1/2" High
22" Deep
The compactor requires an under-counter opening 15-in.
wide, 34
5
/
-in. high, and 4-in. deep.
8
Plan to provide an electrical
outlet in the opening that
meets all applicable electrical
codes
and
requirements.
See "Grounding Instructions"
section on Page 3 for specific
information.
cord cLamp
The compactor is equipped
with a 6-ft. long power cord.
Use the cord clamp to prevent
excess power cord from being
pinched beneath the cabinet
during installation or service.
Installation
24" d
CORD
CLAMP
5