hit counter script

Ses; Ses Properties - HP P2000 Reference Manual

Msa system
Hide thumbs Also See for P2000:
Table of Contents

Advertisement

ses

Properties
Table 66

ses properties

Name
id
chassis
vendor
product-id
cpld-revision
emp-a-busid
emp-a-targetid
emp-a-rev
emp-a
emp-a-ch-id-rev
emp-b-busid
emp-b-targetid
emp-b-rev
emp-b
emp-b-ch-id-rev
wwpn
topology
status
Example
# show enclosure-status
...
<OBJECT basetype="ses" name="enclosure-environmental" oid="1" format="rows">
<PROPERTY name="id" type="string">031</PROPERTY>
<PROPERTY name="chassis" type="string">3CL842CC0A</PROPERTY>
<PROPERTY name="vendor" type="string">HP</PROPERTY>
<PROPERTY name="product-id" type="string">SPS-CHASSIS</PROPERTY>
<PROPERTY name="cpld-revision" type="string">20</PROPERTY>
<PROPERTY name="emp-a-busid" type="string">01</PROPERTY>
<PROPERTY name="emp-a-targetid" type="string">031</PROPERTY>
<PROPERTY name="emp-a-rev" type="string">1109</PROPERTY>
<PROPERTY name="emp-a" type="string"></PROPERTY>
<PROPERTY name="emp-a-ch-id-rev" type="string">01:031 1109</PROPERTY>
<PROPERTY name="emp-b-busid" type="string">00</PROPERTY>
<PROPERTY name="emp-b-targetid" type="string">031</PROPERTY>
<PROPERTY name="emp-b-rev" type="string">1109</PROPERTY>
<PROPERTY name="emp-b" type="string"></PROPERTY>
<PROPERTY name="emp-b-ch-id-rev" type="string">00:031 1109</PROPERTY>
<PROPERTY name="wwpn" type="string">500c0ff0d8b6cb3c</PROPERTY>
<PROPERTY name="topology" type="string">N/A</PROPERTY>
Type
Description
SCSI ID of the enclosure.
string
Chassis serial number.
string
Enclosure vendor name.
string
Product model identifier.
string
Complex Programmable Logic Device version.
string
SCSI channel ID of controller A's EMP.
string
SCSI target ID of controller A's EMP.
string
Firmware revision of controller A's EMP.
string
Shows the field name EMP A in console format.
string
SCSI address and firmware revision of controller A's EMP.
string
SCSI channel ID of controller B's EMP
string
SCSI target ID of controller B's EMP.
string
Firmware revision of controller B's EMP.
string
Shows the field name EMP B in console format.
string
SCSI address and firmware revision of controller B's EMP.
string
World wide port name of the SES device reporting the enclosure status.
string
Type of topology for the disk channels.
string
N/A
Overall status of the enclosure.
string
Absent: The enclosure is not present.
Error: The enclosure has a fault.
OK: The enclosure is operating normally.
Not Available: Status is not available.
HP P2000 G3 MSA System CLI Reference Guide 393