When you attempt to apply these commands in the ASCII configuration, the following commands fail:
>
>
>
To work around this issue, issue these commands after the commit command.

Availability of F Port Trunking and F Port Channels

Trunking F ports and trunking F port channels are not supported on the following MDS 9000
components:
Trunking F ports, trunking F port channels and regular F port channels are not supported on the following
MDS 9000 components:
For configuration information, refer to the "Configuring Trunking" section in the
Family CLI Configuration

Reserved VSAN Range and Isolated VSAN Range Guidelines

On an NPV switch with a trunking configuration on any interface, or on a regular switch where the
feature fport_channel_trunk command has been issued to enable the F PortChannel feature, follow
these configuration guidelines for reserved VSANs and the isolated VSAN:
OL-17675-05
no destination-profile testProfile transport-method email
destination-profile testProfile transport-method http
destination-profile testProfile http https://xyz.abc.com
destination-profile testProfile alert-group all
transport email smtp-server 64.104.140.134 port 25 use-vrf management
transport email from abc@cisco.com <mailto:abc@cisco.com>
enable
commit
no destination-profile testProfile transport-method email
destination-profile testProfile transport-method http
destination-profile testProfile http
DS-C9134-K9, Cisco MDS 9134 Multilayer Fabric Switch, if NPIV is enabled and the switch is
used as the NPV core switch
DS-C9124-K9, Cisco MDS 9124 Multilayer Fabric Switch, if NPIV is enabled and the switch is
used as the NPV core switch
DS-C9216i-K9, Cisco MDS 9216i Multilayer Fabric Switch
DS-X9016, Cisco MDS 9000 2-Gbps16-Port Fibre Channel Switching Module
DS-X9032, Cisco MDS 9000 2-Gbps 32-Port Fibre Channel Switching Module
DS-X9032-14K9, Cisco MDS 9000 14/2-Port Multiprotocol Services Module (MPS-14/2)
Guide.
Cisco MDS 9000 Family Release Notes for Cisco MDS NX-OS Release 4.1(3a)
https://xyz.abc.com
Limitations and Restrictions
Cisco MDS 9000