Chapter 7
Troubleshooting the Installation
Table 7-3
Possible Problems and Solutions for Hardware-Based Out-of-Service States on the Cisco WebEx Node SPA
and SPA-DSP (continued)
Possible Problem
Observations and Comments
Temperature or
•
voltage sensors
have values that are
not in the range of
•
safe operation for
the Cisco WebEx
Node SPA and
SPA-DSP.
Router# show hw-module subslot 0/0 sensors
SPA-WMA-K9[0/0] temperature sensor 0, reading: 31C
SPA-WMA-K9[0/0] temperature sensor 1, reading: 36C
SPA-WMA-K9[0/0] temperature sensor 2, reading: 48C
SPA-WMA-K9[0/0] temperature sensor 3, reading: 51C
SPA-WMA-K9[0/0] temperature sensor 4, reading: 57C
SPA-WMA-K9[0/0] temperature sensor 5, reading: 32C
SPA-WMA-K9[0/0] nominal: 3.300V, reading: 3.257V
SPA-WMA-K9[0/0] nominal: 2.500V, reading: 2.454V
SPA-WMA-K9[0/0] nominal: 5.000V, reading: 5.038V
SPA-WMA-K9[0/0] nominal: 1.200V, reading: 1.195V
SPA-WMA-K9[0/0] nominal: 1.100V, reading: 1.097V
SPA-WMA-K9[0/0] nominal: 1.000V, reading: 0.998V
SPA-WMA-K9[0/0] nominal: 0.900V, reading: 0.892V
SPA-WMA-K9[0/0] nominal: 1.800V, reading: 1.785V
OL-14126-12
The show hw-module subslot all oir command
displays an "Environmental limits exceeded" reason
code.
The show hw-module subslot sensors command
displays the actual values for the temperature and
voltage on the Cisco WebEx Node SPA, as shown in
the following example:
Cisco ASR 1000 Series Aggregation Services Routers SIP and SPA Hardware Installation Guide
Troubleshooting the Hardware
Solutions
Enter the show logging | include
1.
TEMP_SHUTDOWN command and
look for a temperature shutdown error
message.
The following is an example of an
error message due to excessive
temperature:
*Jan 27 17:46:22.285:
%SPA-0-TEMP_SHUTDOWN: SIP1/1:
SPA-WMA-K9[1/1] temperature too
high on sensor 2. (90C) SPA has
been shut down.
If you do not find a temperature
Tip
shutdown error message, it's
possible that the logging buffer
has overflowed from too many
warning messages. Enter the show
logging | include
TEMP_WARNING command to
confirm.
If you find a temperature error
2.
message, then verify that the fan
within the power supply is working
correctly.
Refer to the "Troubleshooting the
Cooling Subsystem" section of the
"Troubleshooting Initial Startup
Problems" chapter in the
1000 Series Aggregation Services
Router Hardware Installation
If no temperature error message is
3.
found, enter the show logging |
include VOLT_SHUTDOWN
command to find a voltage shutdown
error message.
If an error messages indicates a
voltage problem, then the SIP could
be providing an unstable voltage to
the SPA, or there might be a hardware
problem on the Cisco WebEx Node
SPA itself.
Try installing the SPA into another
SIP and see if the problem continues.
If the problem still occurs, then there
is a voltage problem on the Cisco
WebEx Node SPA.
Cisco ASR
Guide.
7-5