QUICK START INSTALLATION GUIDE
VersiCharge
AC
Electric vehicle
charging station
July 2024
VersiCharge™ AC

Advertisement

loading

Summary of Contents for Siemens VersiCharge AC

  • Page 1 QUICK START INSTALLATION GUIDE VersiCharge ™ Electric vehicle charging station July 2024 VersiCharge™ AC...
  • Page 2 VersiCharge™ AC Electric vehicle charging station Installation Kit Equipment List Standard Installation – What you will need: Certified electrician (recommended) Cordless drill (Phillips bit with extender) – include Stud finder Level 1/8” drill bit for pilot holes 240 V AC voltmeter NEMA 6-50 outlet (only used for the 40 A 7/16”...
  • Page 3 User Card User Card NOTE: Supplied with commercial units only. For RFID setup, refer to the RFID Setup section in the complete VersiCharge Installation and Operations Manual at: usa.siemens.com/versicharge. 1 – Mounting bracket 1 – Cable holster 2 – Admin Cards 5 –...
  • Page 4 VersiCharge™ AC Electric vehicle charging station Hardwire Bending Diagrams Residential variants Commercial variants NOTE: Follow local and national codes where applicable for rating supply equipment to the EVSE based on the charger’s amp adjustment switch; 40 A requires a 50 A breaker, and 48 A requires a 60 A breaker. The wiring should not be exposed to any conditions that could potentially damage wiring or cause a potential hazard.
  • Page 5 Mount in compliance with all National Electrical Code® (NEC) and local jurisdiction requirements. For Siemens post-installation, see the post instruction manual at usa.siemens.com/versichargecommercial, under the Installation section. Step 1B: Alternate mounting – wallboard installation NOTE: Anchor rating: five anchors must be rated as 61 lb.
  • Page 6 VersiCharge create case site, located here: https:// siemens-smartinfrastructure.force.com/SI/s/createcase. Alternatively, support can be reached by calling (855) 950-6339, option 9. There is one ferrite core for each wire. Wrap each wire (L1, L2 and ground) two times through the ferrite core.
  • Page 7 Push the external Modbus cable through the hole of the waterproof membrane of the gland. Gently tuck the wiring into the space. NOTE: For more information, see the Modbus Manual and the Modbus Communications Setup in the VersiCharge AC Series Install and Operations Manual at usa.siemens.com/versichargecommercial, under the Installation section.
  • Page 8 ON). NOTE: For more details on the Modbus and the termination switch position settings, refer to the complete VersiCharge AC Series Installation and Operation Manual at usa.siemens.com/versichargecommercial, under the Installation section.
  • Page 9 VersiCloud before commissioning the chargers at https://versichargesg.com/account. If assistance is needed, create a support ticket at https://sieops.my.site.com/eMobilityCloud. Visit usa.siemens.com/versichargeinstall for additional instructions and information or scan the QR code below to learn how to easily install your VersiCharge AC level 2 EV charger.
  • Page 10 This document contains a general description of available technical options only and its effectiveness will be subject to specific variables, Siemens Industry, Inc. including field conditions and project parameters. Siemens does not 3617 Parkway Ln. make representations, warranties, or assurances as to the accuracy or Peachtree Corners, GA 30092 completeness of the content contained herein.