Fan Module LEDs
LED
(SYNC)
Link
(per-port)
M a n a g e m e n t
Port
Activity
M a n a g e m e n t
Port
Link
Fan Module LEDs
The fan module LED is located below the air holes on the front of the module.
LED
STS
Power Supply LEDs
The power supply LEDs are located on the left right portion of the power supply. Combinations of states
indicated by the Okay and Fault LEDs indicate the status for the module as shown in the following table.
Cisco Nexus 9232E-B1 NX-OS Mode Switch Hardware Installation Guide
42
Color
Status
The frequency, time and phase are synchronized to an external interface. The external
Green
interface could be;
• BITS
• GPS
Recovered RX Clock
Amber
The system is running in holdover/free-run mode and it is not synchronized to an external
interface as expected based on user configuration.
Off
The centralized frequency/time and phase distribution is not enabled. Therefore all clocking
is based on the local oscillator on the RSP.
Off
The RP/RSP is in the Standby state.
Green
The port is active.
Amber
The port is disabled by the operator or is not initializing.
Flashing amber
The port is faulty and disabled.
Off
The port is not active or the link is not connected.
Green
The ethernet link is up and operational.
Off
The ethernet link is down.
The port is either receiving or transmitting packets.
Yellow
Off
No packets are being received or transmitted.
Color
Status
Green
The fan module is operational.
Red
The fan module is not operational (fan is probably not functional).
Off
Fan module is not receiving power.
LEDs