hit counter script

100 To 240 V Ac / 110 To 250 V Dc Device Versions - Siemens SCALANCE XR-500 Operating Instructions Manual

Simatic net industrial ethernet switches
Hide thumbs Also See for SCALANCE XR-500:
Table of Contents

Advertisement

Technical specifications
9.2 SCALANCE XR522-12
Technical specifications
Conformal coating of the PCBs
Design of the mounting bracket for four-point mounting
Dimensions (W x H x D)
Plate thickness
Bending radii
Surface of the housing
Mean time between failure (MTBF)
MTBF (EN/IEC 61709; 40 °C)
Wiring rules
1)
Note the wiring rules (Page 65).
Ambient temperature with SFP
2)
The maximum ambient temperature during operation depends on the operating elevation
and the installed plug-in transceivers, see also the section "SFP plug-in transceiver (Page 36)"
in the "Accessories" section.
Restriction when operating with plug-in transceivers of this type
3)
No more than two plug-in transceivers of this type may be used in each of the 4 x SFP as well
as 8 x SFP+ slots.
Derating
4)
The derating values depend on the maximum ambient temperatures during operation up to
2000 m.
Degree of protection
5)
The degree of protection was not examined in the context of UL certification.
Degree of protection
6)
The degree of protection was not examined in the context of FM certification.
9.2.2
100 to 240 V AC / 110 to 250 V DC device versions
The following technical specifications apply to the 100 to 240 V AC / 110 to 250 V DC device
versions of the SCALANCE XR522-12.
Technical specifications
Connection to Industrial Ethernet
Electrical connectors
100
No
43.6 x 43.6 x 18.3 mm (1 height unit)
1.5 mm
1.5 mm
Stainless steel X6CR17
> 13.2 years
Quantity
Connector
Transmission speed
Properties
20
RJ45 jack
10 / 100 / 1000 Mbps
Half/full duplex, MDI‑X pinning
Operating Instructions, 07/2023, C79000-G8976-C692-01
2
RJ45 jack
1 / 2.5 / 5 / 10 Gbps
SCALANCE XR-500