Maintenance
10.5 Corrective maintenance
You have now set the air gap.
Table 10-7
Brake type
L4/1,4
L4/2
L4/3
L4
L4/5
L8/3, L8/4
L8/5, L8/6,3
L8
L8/10
L16/4, L16/8, L16/10,
L16/13, L16
L16/20
L32/8, L32/14, L32/18,
L60/25, L60/35
L32/23, L60/38
L32, L60/50, L60
L32/40
L80/25, L80/35, L80/50,
L80/63, L80
L80/100
L150/45, L150/60, L150/80,
L150/100,
L150/125, L150
L260/80, L260/100, L260/145,
L260/180, L260/200,
L260/240, L260
L260/315
L400/145, L400/175,
L400/265, L400/300,
L400/360, L400
L400/600
FDX30
FDX40
122
Air gap values
Nominal air
gap
s
LN
(+0.1 / -0.05)
mm
0.2
0.3
0.4
0.5
0.5
0.6
Maximum air gap for
Standard excita‐
Overexcitation
tion
s
Lmax.
s
Lmax.
mm
mm
0.65
0.7
0.6
0.55
0.5
0.4
0.6
0.55
0.5
0.45
0.6
0.8
0.5
0.9
0.9
0.85
0.75
0.65
0.9
0.7
1.2
1.2
1.5
1.05
1.5
1.8
0.9
-
1.9
-
1.7
Operating Instructions, 10/2023, A5E46712792A
Reference
gage
s
HL
mm
1.0
1.5
2.0
2.5
-
-